All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Electrical Variable Speed Drives

Subcategories

    Inverter Drive AC

    Inverter Drive Parts and Accessories

    Motor Control Drive DC

    Variable speed drive

Danfoss 131H5358 - VLT® AutomationDrive FC 302, 37 kW / 50 HP, 380-500 V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 50 HP, 65 A continuous, frame C3
Danfoss

131H5358

FC-302P37KT5E20H2BGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 37 kW / 50 HP, 380-500 V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 50 HP, 65 A continuous, frame C3

Contact for Pricing

Danfoss 131L0224 - VLT® AQUA Drive FC 202, 45 kW / 60 HP, Three phase 525-600V, IP 55/NEMA Type 12, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 62 A continuous, frame C1
Danfoss

131L0224

FC-202P45KT6E55HXXGXXXXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 45 kW / 60 HP, Three phase 525-600V, IP 55/NEMA Type 12, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 62 A continuous, frame C1

Contact for Pricing

Danfoss 131L5582 - VLT® AutomationDrive FC 302, 11 kW / 15 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 15 HP, 21 A continuous, frame B1
Danfoss

131L5582

FC-302P11KT5E21H2XGX3XXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 11 kW / 15 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 15 HP, 21 A continuous, frame B1

Contact for Pricing

Danfoss 131U1660 - VLT® AutomationDrive FC 302, 15 kW / 20 HP, 525-600 V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 20 HP, 22 A continuous, frame B1
Danfoss

131U1660

FC-302P15KT6E21HXXGX3XXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 15 kW / 20 HP, 525-600 V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 20 HP, 22 A continuous, frame B1

Contact for Pricing

Danfoss 131X6544 - VLT® AQUA Drive FC 202, 15 kW / 20 HP, Three phase 380-480V, IP 66, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Imperial cable entries, 27 A continuous, frame B1
Danfoss

131X6544

FC-202P15KT4E66H2XGX3SXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 15 kW / 20 HP, Three phase 380-480V, IP 66, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Imperial cable entries, 27 A continuous, frame B1

Contact for Pricing

Danfoss 131X7119 - VLT® AutomationDrive FC 302, 11 kW / 15 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 15 HP, 46.2 A continuous, frame B2
Danfoss

131X7119

FC-302P11KT2E55H2XGXXSXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 11 kW / 15 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 15 HP, 46.2 A continuous, frame B2

Contact for Pricing

Danfoss 131X7311 - VLT® AutomationDrive FC 301, 5.5 kW / 7.5 HP, 380-480 V, IP 66, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, 7-1/2 HP, 11 A continuous, frame A5
Danfoss

131X7311

FC-301P5K5T4E66H2BGXXSXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 5.5 kW / 7.5 HP, 380-480 V, IP 66, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, 7-1/2 HP, 11 A continuous, frame A5

Contact for Pricing

Danfoss 131X7343 - VLT® AutomationDrive FC 302, 15 kW / 20 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 20 HP, 27 A continuous, frame B1
Danfoss

131X7343

FC-302P15KT5E55H2BGXXSXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 15 kW / 20 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 20 HP, 27 A continuous, frame B1

Contact for Pricing

Danfoss 131X9976 - VLT® AutomationDrive FC 302, 18.5 kW / 25 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 25 HP, 34 A continuous, frame B2
Danfoss

131X9976

FC-302P18KT5E55H2XGXXSXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 18.5 kW / 25 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries (A4,A5,B2,C1,C2 only), 25 HP, 34 A continuous, frame B2

Contact for Pricing

Danfoss 131Z3000 - VLT® AQUA Drive FC 202, 22 kW / 30 HP, Three phase 525-600V, IP 55/NEMA Type 12, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries, 34 A continuous, frame B2
Danfoss

131Z3000

FC-202P22KT6E55HXXGXXSXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 22 kW / 30 HP, Three phase 525-600V, IP 55/NEMA Type 12, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries, 34 A continuous, frame B2

Contact for Pricing

Danfoss 131Z5182 - VLT® AQUA Drive FC 202, 2.2 kW / 3.0 HP, Three phase 525-600V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 3.9 A continuous, frame A3
Danfoss

131Z5182

FC-202P2K2T6E21HXXGX3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 2.2 kW / 3.0 HP, Three phase 525-600V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 3.9 A continuous, frame A3

Contact for Pricing

Danfoss 132L4012 - VLT® AutomationDrive EZ FC 321, 2.2 kW / 3.0 HP, 380-500 V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 3 HP, 4.8 A continuous, frame A2
Danfoss

132L4012

FC-321P2K2T5E20H2BGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive EZ FC 321, 2.2 kW / 3.0 HP, 380-500 V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 3 HP, 4.8 A continuous, frame A2

Contact for Pricing