All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Electrical Relays And Accessories

Subcategories

    Alternating Relay

    Auxiliary relay

    Control Relay

    Current Monitoring Relay

    Direct Current Relay

    Electromagnetic relay

    General Purpose Relay

    Latching relay

    Liquid Level Control Relay

    Overload Relay

    Phase Failure Relay

    Power relay

    Protection Relay

    Relay board or multiple relay module

    Relay Socket Or Base

    Selecting Ground Relay

    Socket relay

    Solid State Relay

    Time Relay

    Turn Signal Flasher Relay

    Unground relay

Showing 889-900 of 1,100 results

Littelfuse T3100.0010 - Voltage Relay. 230V. The T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function.
Littelfuse · Relay Series

T3100.0010


Voltage Relay. 230V. The T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function.

Contact for Pricing

Littelfuse T4500.0040 - Auto Synchronizer. 63/110V. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Littelfuse · Relay Series

T4500.0040


Auto Synchronizer. 63/110V. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.

Contact for Pricing

Littelfuse T4500.0090 - Auto Synchronizer. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Littelfuse · Relay Series

T4500.0090


Auto Synchronizer. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.

Contact for Pricing

Littelfuse T3300.0020 - Voltage Relay. 33 400/450V. The T3300 is intended for three phase effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function. The T3300 includes a total of four internal transformers. Three of these transformers are used for measurement and one dedicated to supplying the internal electronics. The internal transformers provide optimal isolation and the best possible accuracy. The use of a dedicated transformer for supply prevents load disturbance to any of the three measurements.
Littelfuse · Relay Series

T3300.0020


Voltage Relay. 33 400/450V. The T3300 is intended for three phase effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function. The T3300 includes a total of four internal transformers. Three of these transformers are used for measurement and one dedicated to supplying the internal electronics. The internal transformers provide optimal isolation and the best possible accuracy. The use of a dedicated transformer for supply prevents load disturbance to any of the three measurements.

Contact for Pricing

Littelfuse EFCT-2W/OFC - The EFCT series is a sensitive nickel-core current transformer used with Littelfuse relays to detect low levels of earth-leakage current.
Littelfuse · Relay Series

EFCT-2W/OFC

EFCT-2W/OFC


The EFCT series is a sensitive nickel-core current transformer used with Littelfuse relays to detect low levels of earth-leakage current.

Contact for Pricing

Littelfuse E7800.0760 - Motorized Potentiometer24VDC,10 turn, 2k. The E7800 Motorized Potentiometer is typically used as an interface between increase/decrease relay contacts (or push buttons) and a device requiring control by an external potentiometer (e.g. the speed trim of an electronic governor). All three wires of the potentiometer are directly accessible on external connection terminals, thus providing the best possible flexibility for almost any application. A special version of the E7800 with DC voltage output is also available. The DC output voltage follows the position of the potentiometer. The design of the E7800 ensures that the potentiometer will “remember” its position although supply is lost
Littelfuse · E7800 Series

E7800.0760


Motorized Potentiometer24VDC,10 turn, 2k. The E7800 Motorized Potentiometer is typically used as an interface between increase/decrease relay contacts (or push buttons) and a device requiring control by an external potentiometer (e.g. the speed trim of an electronic governor). All three wires of the potentiometer are directly accessible on external connection terminals, thus providing the best possible flexibility for almost any application. A special version of the E7800 with DC voltage output is also available. The DC output voltage follows the position of the potentiometer. The design of the E7800 ensures that the potentiometer will “remember” its position although supply is lost

Contact for Pricing

Littelfuse H2000.0020 - Engine Controller 20. Engine Controller.
Littelfuse · Relay Series

H2000.0020


Engine Controller 20. Engine Controller.

Contact for Pricing

Littelfuse AC700-CUA-02 - Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.
Littelfuse · AC 700 Series

AC700-CUA-02

AC700-CUA-02


Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.

Contact for Pricing

Littelfuse B6000.0070 - Basic Unit. B6000 generator protection system is designed for protection of parallel working AC generators. Besides reverse power and overload protection, this system also includes short circuit protection. Optionally, the system can be equipped with frequency detection. The relay can be provided with two extra overcurrent/time units which can be used for alarms and/or tripping of non-essential load. It is also possible to obtain normally energized or normally de-energinzed output relay functions for each of the output relays. Basic unit.
Littelfuse · Relay Series

B6000.0070


Basic Unit. B6000 generator protection system is designed for protection of parallel working AC generators. Besides reverse power and overload protection, this system also includes short circuit protection. Optionally, the system can be equipped with frequency detection. The relay can be provided with two extra overcurrent/time units which can be used for alarms and/or tripping of non-essential load. It is also possible to obtain normally energized or normally de-energinzed output relay functions for each of the output relays. Basic unit.

Contact for Pricing

Littelfuse AC700-CUA-08 - EL700 SERIES COMM ADAPTER, RS232. Communications Adapter. Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.
Littelfuse · AC 700 Series

AC700-CUA-08


EL700 SERIES COMM ADAPTER, RS232. Communications Adapter. Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.

Contact for Pricing

Littelfuse FPU-32-04-00 - The FPU-32 Feeder Protection Unit provides integrated protection, metering, and data-logging functions. It is an excellent choice for retrofitting and upgrading older relays because of its compact size and ability to use existing CTs. The FPU-32 is used to protect distribution feeders in processing, manufacturing, petroleum, chemical, and wastewater treatment facilities.
Littelfuse · FPU-32 Series

FPU-32-04-00

FPU-32-04-00


The FPU-32 Feeder Protection Unit provides integrated protection, metering, and data-logging functions. It is an excellent choice for retrofitting and upgrading older relays because of its compact size and ability to use existing CTs. The FPU-32 is used to protect distribution feeders in processing, manufacturing, petroleum, chemical, and wastewater treatment facilities.

Contact for Pricing

Littelfuse AC700-CUA-03 - Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.
Littelfuse · AC 700 Series

AC700-CUA-03

AC700-CUA-03


Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.

Contact for Pricing

Showing 889-900 of 1,100 results