Showing 685-696 of 1,100 results

Littelfuse · Relay Series
T3000.0040
T3000 Frequency Relay. 415/480V. The T3000 is intended for effective frequency surveillance on generators, busbar or other distribution systems. The relay contains the functions “under frequency” and “over frequency” time delayed, and 2 individual output relays, one relay for each function.
Contact for Pricing

Littelfuse · Relay Series
T3100.0030
Voltage Relay 230V. The T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function.
Contact for Pricing

Littelfuse · Relay Series
T3100.0040
Voltage Relay. 31 415/480V. The T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function.
Contact for Pricing

Littelfuse · Relay Series
T3200.0020
Insulation Monitoring Relay. 400/450V. The Insulation Monitoring Relay T3200 is intended for continuous insulation monitoring on three phase insulated networks on board ships. The relay monitors continuously two systems galvanically separated from each other, e.g. the busbar and the lighting system, or two busbar systems. The unit features two output relays for alarm purposes and two analogue outputs for instrument reading. The instrument is not included with the relay. Instruments are available from as standard sized switchboard component.
Contact for Pricing

Littelfuse · Relay Series
T4500.0030
Auto Synchronizer. 415/480V. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Contact for Pricing

Littelfuse · Relay Series
T3100.0020
Voltage Relay. 31 400/450V. The T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function.
Contact for Pricing

Littelfuse · Relay Series
T3200.0080
Insulation Monitoring Relay. The Insulation Monitoring Relay T3200 is intended for continuous insulation monitoring on three phase insulated networks on board ships. The relay monitors continuously two systems galvanically separated from each other, e.g. the busbar and the lighting system, or two busbar systems. The unit features two output relays for alarm purposes and two analogue outputs for instrument reading. The instrument is not included with the relay. Instruments are available from as standard sized switchboard component.
Contact for Pricing

Littelfuse · Relay Series
T4500.0050
Auto Synchronizer. 120/127V 5A. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Contact for Pricing

Littelfuse · Relay Series
T4500.0060
Auto Synchronizer. 100/110V. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Contact for Pricing

Littelfuse · Relay Series
T4500.0080
Auto Synchronizer 80. The T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. The T4500 measures the voltage across two phases on either side of the circuit breaker in order to obtain data on frequency, phase and voltage deviation. The T4500 will automatically adjust the speed of the generator (through the governor) in order to match the frequency and phase to the live busbar. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller. The T4500 will continuously adjust the generator speed until frequency and phase is within limits. The signal to close the circuit breaker is issued just before phase accordance is obtained. This is done in order to compensate for the circuit breaker make time.
Contact for Pricing

Littelfuse · Relay Series
T3200.0060
Insulation Monitoring Relay. 120/127V. The Insulation Monitoring Relay T3200 is intended for continuous insulation monitoring on three phase insulated networks on board ships. The relay monitors continuously two systems galvanically separated from each other, e.g. the busbar and the lighting system, or two busbar systems. The unit features two output relays for alarm purposes and two analogue outputs for instrument reading. The instrument is not included with the relay. Instruments are available from as standard sized switchboard component.
Contact for Pricing

Littelfuse · Relay Series
T4800.0030
Load Sharer. 415/480V 5A. The T4800 is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4800 units). The T4800 will continuously measure and compare the active current on the generator to an external DC reference signal connected to the “parallel lines” input. The T4800 will increase or decrease the speed of the generator (through the governor) if it finds the active current level to be either too low or two high. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller.
Contact for Pricing