All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Electrical Relays And Accessories

Subcategories

    Alternating Relay

    Auxiliary relay

    Control Relay

    Current Monitoring Relay

    Direct Current Relay

    Electromagnetic relay

    General Purpose Relay

    Latching relay

    Liquid Level Control Relay

    Overload Relay

    Phase Failure Relay

    Power relay

    Protection Relay

    Relay board or multiple relay module

    Relay Socket Or Base

    Selecting Ground Relay

    Socket relay

    Solid State Relay

    Time Relay

    Turn Signal Flasher Relay

    Unground relay

Showing 541-552 of 1,100 results

Littelfuse RK-105I - Remote indication and reset for the SE-105 and SE-107.
Littelfuse · RK 105 Series

RK-105I

RK-105I


Remote indication and reset for the SE-105 and SE-107.

Contact for Pricing

Littelfuse SE-330AU-02-00 - NEUTRAL-EARTHING-RESISTOR MON. PROFIBUS. The SE-330AU is an advanced earth-fault and earthing-resistor monitoring relay for low- and medium-voltage transformers and generators. It monitors neutral current, neutral-to-earth voltage, and neutral-to-earth resistance. It provides continuous monitoring of the neutral-to-earth path to verify that the neutral-earthing resistor (NER)is intact. This is of utmost importance—an open NER renders current-sensing earth-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330AU earth-fault function complies with AS/NZS 2081.3:2002. For non-AS/NZS 2081 applications, see the SE-330 or SE-330HV. The SE-330AU New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Earth-fault trip level is adjustable from 0.125 to 5A (EFCT) or 0.75 to 30A (CS30). When set to MEM, the earth-fault trip level is adjustable from 2 to 100percent in 1percent increments of the CT-primary rating. SE-MON330 V3.2 or later is required. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330AU to the network using a standard Ethernet patch cable. Use of a crossover cable to connect the SE-330AU directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330AU does not support the use of DHCP. If the SE-330AU is being set-up for first time, it is recommended to only have one SE-330AU connected to the network to prevent communication errors.
Littelfuse · SE 330 Series

SE-330AU-02-00


NEUTRAL-EARTHING-RESISTOR MON. PROFIBUS. The SE-330AU is an advanced earth-fault and earthing-resistor monitoring relay for low- and medium-voltage transformers and generators. It monitors neutral current, neutral-to-earth voltage, and neutral-to-earth resistance. It provides continuous monitoring of the neutral-to-earth path to verify that the neutral-earthing resistor (NER)is intact. This is of utmost importance—an open NER renders current-sensing earth-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330AU earth-fault function complies with AS/NZS 2081.3:2002. For non-AS/NZS 2081 applications, see the SE-330 or SE-330HV. The SE-330AU New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Earth-fault trip level is adjustable from 0.125 to 5A (EFCT) or 0.75 to 30A (CS30). When set to MEM, the earth-fault trip level is adjustable from 2 to 100percent in 1percent increments of the CT-primary rating. SE-MON330 V3.2 or later is required. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330AU to the network using a standard Ethernet patch cable. Use of a crossover cable to connect the SE-330AU directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330AU does not support the use of DHCP. If the SE-330AU is being set-up for first time, it is recommended to only have one SE-330AU connected to the network to prevent communication errors.

Contact for Pricing

Littelfuse SE-107EL - GF-GC MONITOR UVR LATCHING GC 240 VAC. The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Littelfuse · SE 107 Series

SE-107EL


GF-GC MONITOR UVR LATCHING GC 240 VAC. The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.

Contact for Pricing

Littelfuse SE-107L - The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Littelfuse · SE 107 Series

SE-107L

SE-107L


The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.

Contact for Pricing

Littelfuse SE-330AU-22-01 - NEUTRAL-EARTHING-RES MON 48VDC PROFI NC. The SE-330AU is an advanced earth-fault and earthing-resistor monitoring relay for low- and medium-voltage transformers and generators. It monitors neutral current, neutral-to-earth voltage, and neutral-to-earth resistance. It provides continuous monitoring of the neutral-to-earth path to verify that the neutral-earthing resistor (NER)is intact. This is of utmost importance—an open NER renders current-sensing earth-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330AU earth-fault function complies with AS/NZS 2081.3:2002. For non-AS/NZS 2081 applications, see the SE-330 or SE-330HV. The SE-330AU New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Earth-fault trip level is adjustable from 0.125 to 5A (EFCT) or 0.75 to 30A (CS30). When set to MEM, the earth-fault trip level is adjustable from 2 to 100percent in 1percent increments of the CT-primary rating. SE-MON330 V3.2 or later is required. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330AU to the network using a standard Ethernet patch cable. Use of a crossover cable to connect the SE-330AU directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330AU does not support the use of DHCP. If the SE-330AU is being set-up for first time, it is recommended to only have one SE-330AU connected to the network to prevent communication errors.
Littelfuse · SE 330 Series

SE-330AU-22-01


NEUTRAL-EARTHING-RES MON 48VDC PROFI NC. The SE-330AU is an advanced earth-fault and earthing-resistor monitoring relay for low- and medium-voltage transformers and generators. It monitors neutral current, neutral-to-earth voltage, and neutral-to-earth resistance. It provides continuous monitoring of the neutral-to-earth path to verify that the neutral-earthing resistor (NER)is intact. This is of utmost importance—an open NER renders current-sensing earth-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330AU earth-fault function complies with AS/NZS 2081.3:2002. For non-AS/NZS 2081 applications, see the SE-330 or SE-330HV. The SE-330AU New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Earth-fault trip level is adjustable from 0.125 to 5A (EFCT) or 0.75 to 30A (CS30). When set to MEM, the earth-fault trip level is adjustable from 2 to 100percent in 1percent increments of the CT-primary rating. SE-MON330 V3.2 or later is required. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330AU to the network using a standard Ethernet patch cable. Use of a crossover cable to connect the SE-330AU directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330AU does not support the use of DHCP. If the SE-330AU is being set-up for first time, it is recommended to only have one SE-330AU connected to the network to prevent communication errors.

Contact for Pricing

Littelfuse SE-105D - The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Littelfuse · SE 105 Series

SE-105D

SE-105D


The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.

Contact for Pricing

Littelfuse SE-330AU-03-00 - SE-330AU-03-00 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).
Littelfuse · SE 330 Series

SE-330AU-03-00

SE-330AU-03-00


SE-330AU-03-00 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).

Contact for Pricing

Littelfuse SE-330AU-21-00 - SE-330AU-21-00 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 28–52 and a supply voltage dc of 36–72. Network communications is offered via USB; DeviceNet.
Littelfuse · SE 330 Series

SE-330AU-21-00

SE-330AU-21-00


SE-330AU-21-00 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 28–52 and a supply voltage dc of 36–72. Network communications is offered via USB; DeviceNet.

Contact for Pricing

Littelfuse 1N5339B - Provides a 5-W ground-check termination between the ground-check wire and ground.
Littelfuse · 1N5339B Series

1N5339B

1N5339B


Provides a 5-W ground-check termination between the ground-check wire and ground.

Contact for Pricing

Littelfuse SE-703-0T - EARTH-LEAKAGE MONITOR - 32 TO 70 VDC. The SE-703 is a microprocessor-based ground-fault relay for resistance- and solidly-earthed systems. It offers sensitive ground-fault detection as low as 25 mA and can be used on systems with significant harmonic content. The SE-703 provides feeder-level protection or individual-load protection. The output contacts can be connected for use in protective tripping circuits or in alarm indication circuits. The analog output can be used with a PLC or a meter. The SE-703 is specifically designed to be Australian AS/NZS 2081 compliant.
Littelfuse · SE 703 Series

SE-703-0T


EARTH-LEAKAGE MONITOR - 32 TO 70 VDC. The SE-703 is a microprocessor-based ground-fault relay for resistance- and solidly-earthed systems. It offers sensitive ground-fault detection as low as 25 mA and can be used on systems with significant harmonic content. The SE-703 provides feeder-level protection or individual-load protection. The output contacts can be connected for use in protective tripping circuits or in alarm indication circuits. The analog output can be used with a PLC or a meter. The SE-703 is specifically designed to be Australian AS/NZS 2081 compliant.

Contact for Pricing

Littelfuse T3300.0040 - Voltage Relay. 33 415/480V. The T3300 is intended for three phase effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function. The T3300 includes a total of four internal transformers. Three of these transformers are used for measurement and one dedicated to supplying the internal electronics. The internal transformers provide optimal isolation and the best possible accuracy. The use of a dedicated transformer for supply prevents load disturbance to any of the three measurements.
Littelfuse · Relay Series

T3300.0040


Voltage Relay. 33 415/480V. The T3300 is intended for three phase effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions “under voltage” and “over voltage” time delayed, and 2 individual output relays, one relay for each function. The T3300 includes a total of four internal transformers. Three of these transformers are used for measurement and one dedicated to supplying the internal electronics. The internal transformers provide optimal isolation and the best possible accuracy. The use of a dedicated transformer for supply prevents load disturbance to any of the three measurements.

Contact for Pricing

Littelfuse T4900.0010 - VAr Load Sharer. 400/450V 5A. The T4900 is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4900 units). The T4900 will continuously measure and compare the reactive current on the generator to an external DC reference signal connected to the “parallel line” input. The T4900 will increase or decrease the voltage of the generator (through the AVR) if it finds the reactive current level to be either too low or too high. Two built-in relays provide the increase and decrease pulses for the automatic voltage regulator (AVR). The strength (width) of the pulses is proportional to the voltage deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for most AVR’s.
Littelfuse · Relay Series

T4900.0010


VAr Load Sharer. 400/450V 5A. The T4900 is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4900 units). The T4900 will continuously measure and compare the reactive current on the generator to an external DC reference signal connected to the “parallel line” input. The T4900 will increase or decrease the voltage of the generator (through the AVR) if it finds the reactive current level to be either too low or too high. Two built-in relays provide the increase and decrease pulses for the automatic voltage regulator (AVR). The strength (width) of the pulses is proportional to the voltage deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for most AVR’s.

Contact for Pricing

Showing 541-552 of 1,100 results