Showing 8173-8184 of 54,867 results

Medium Voltage Potential Transformer Fuse 5500VAC 1A Ferrule Series: BDD Visual Indicator Amp-Trap®
Contact for Pricing

Contact for Pricing

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 25800 Volts EK-1D AHM series.
Contact for Pricing

Contact for Pricing

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 5500 Volts EK-3C ACB series.
Contact for Pricing

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 15500 Volts EK-3D AGJ series.
Contact for Pricing

Fuse AJT - Class J - Time-delay 600VAC 500VDC 350A Blade EI-B Indicator Amp-Trap 2000®
Contact for Pricing

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 1000 Volts PV system type with microswitch .
Contact for Pricing

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 12A Ferrule SmartSpot® Tri-Onic®
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 25A Ferrule SmartSpot® Tri-Onic®
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

250V,Fast Acting Glass 5mm x 20mm 250 Volts 5 Amps GGM (bulk packaging) series.
Contact for Pricing