Showing 6589-6600 of 54,864 results

DIN NH Standard fuse-link aM Size NH000 500VAC 16A live tags Double indicator Body width 21mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH000 690VAC 250VDC 32A live tags Double indicator Body width 21mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link aM Size NH000 690VAC 35A live tags Double indicator Body width 21mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH0 500VAC 250VDC 125A live tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH1 500VAC 250VDC 224A live tags Double indicator Body width 40 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

Fuse Holder Modulostar® Size 22x58 IEC 690VAC 690VDC 1-Pole IP20 With Microswitch
Contact for Pricing
Minimum Qty: 6
Multiplier: 6
*Contact for lower quantities*

Fuse Holder Modulostar® Size 22x58 IEC 690VAC 690VDC 3-Pole IP20 With Microswitch
Contact for Pricing
Minimum Qty: 2
Multiplier: 2
*Contact for lower quantities*

Fuse Holder Modulostar® Size 22x58 IEC 690VAC 690VDC 3-Pole With Visual Indicator 2x Microswitch IP20
Contact for Pricing
Minimum Qty: 2
Multiplier: 2
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH1 500VAC 250VDC 40A live tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH2 500VAC 250VDC 125A live tags Double indicator Body width 40 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 100 Amps gG NH00 series.
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 35 Amps gG NH00 with puller lugs series.
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*