Showing 6313-6324 of 54,864 results

DIN NH Standard fuse-link gG Size NH00 690VAC 250VDC 80A isolated tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH1 500VAC 250VDC 355A live tags Double indicator Body width 40 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH0 690VAC 400VDC 16A live tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH3 690VAC 250VDC 300A live tags Double indicator Body width 52 mm
Contact for Pricing

DIN NH Standard fuse-link gG Size NH0 690VAC 400VDC 50A live tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH1 690VAC 400VDC 100A isolated tags Double indicator Body width 30 mm
Contact for Pricing

DIN NH Standard fuse-link gG Size NH1 690VAC 400VDC 160A isolated tags Double indicator Body width 40 mm
Contact for Pricing

The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 6 Amps gG NH0 with puller lugs series.
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link gG Size NH0 690VAC 400VDC 100A isolated tags Double indicator Body width 30 mm
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*

DIN NH Standard fuse-link aM Size NH3 500VAC 315A live tags Double indicator Body width 71.9mm
Contact for Pricing

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips. 5500 Volts 175 amps HJD series.
Contact for Pricing

Medium Voltage Potential Transformer Fuse 5500VAC 1A Ferrule Series: BBD-AG Visual Indicator Amp-Trap®
Contact for Pricing