ABB Low Voltage Drives DCS800-S02-1000-05+L508+S171 MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 250 HP @ 230…
Alternate Item Number: 3AUA0000043110
UPC: 662348074992
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 4-Quadrant Reversing Drive
- 250 HP @ 230 VAC / 600 HP @ 460 VAC
- 952 A @ 240 VDC / 965 A @ 500 VDC Output Current
- UL Type OPEN (IP00) Rated
- Wall-Mount, DDCS Communications Board
Specifications
Connection Type | 3-phase |
Connection Type | 3-Phase Input |
Current Rating | 952 A @ 240 VDC / 965 A @ 500 VDC |
Current Rating | 952-965 A |
IP Rating | IP00 |
Mounting Type | Wall-mount |
Poles | 3 |
Poles | 3-Phase |
Series | DCS800 |
Size | 25.4 in x 10.6 in x 13.6 in |
Voltage Rating | 230 VAC/240 VDC & 460 VAC/500 VDC |
Voltage Rating | 230/460 VAC & 240/500 VDC |
Package Dimensions (L x W x H) | 32 in x 24 in x 24 in |
Package Dimensions (L x W x H) | 81.28 cm x 60.96 cm x 60.96 cm |
Package Weight (Imperial) | 103.000 L |
Package Weight (Metric) | 46.721 kg |

DCS800-S02-1000-05+S171
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 250 HP @ 230 VAC / 600 HP @ 460 VAC, Output Current: 952 A @ 240 VDC / 965 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 120 VAC Fan Voltage, 3-Phase Input, Frame: D4, Product HxWxD: 25.4 in x 10.6 in x 13.6 in, Product Weight: 84 lbs
DCS800-S01-0610-05+S171
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 150 HP @ 230 VAC / 300 HP @ 460 VAC, Output Current: 580 A @ 240 VDC / 580 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 120 VAC Fan Voltage, 3-Phase Input, Frame: D4, Product HxWxD: 25.4 in x 10.6 in x 13.6 in, Product Weight: 84 lbs
DCS800-S01-0290-06
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 200 HP, Output Current: 280 A, Voltage: 600 VAC/600 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 3-Phase Input, Frame: D3, Product HxWxD: 18.1 in x 10.6 in x 12.2 in, Product Weight: 55 lbs
DCS800-S01-0315-05
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 75 HP @ 230 VAC / 150 HP @ 460 VAC, Output Current: 300 A @ 240 VDC / 300 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 3-Phase Input, Frame: D3, Product HxWxD: 18.1 in x 10.6 in x 12.2 in, Product Weight: 55 lbs
DCS800-S01-0740-05+S171
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 200 HP @ 230 VAC / 400 HP @ 460 VAC, Output Current: 704 A @ 240 VDC / 704 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 120 VAC Fan Voltage, 3-Phase Input, Frame: D4, Product HxWxD: 25.4 in x 10.6 in x 13.6 in, Product Weight: 84 lbs
DCS800-S01-0470-05
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 125 HP @ 230 VAC / 250 HP @ 460 VAC, Output Current: 447 A @ 240 VDC / 447 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 3-Phase Input, Frame: D3, Product HxWxD: 18.1 in x 10.6 in x 12.2 in, Product Weight: 55 lbs
DCS800-S01-0045-05
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 10 HP @ 230 VAC / 25 HP @ 460 VAC, Output Current: 42 A @ 240 VDC / 42 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 3-Phase Input, Frame: D1, Product HxWxD: 14.6 in x 10.6 in x 7.9 in, Product Weight: 24 lbsFrequently Asked Questions
What is the enclosure rating of the DCS800-S0x power converter module?
The DCS800-S0x power converter module has a NEMA TYPE OPEN (IP00) rating and requires mounting in a protective enclosure.
When should a non-reversing (2-Q) drive be used?
A 2-Q drive is suitable when motor torque and speed are in the same direction and significant stopping power is not needed, like for fans or pumps.
What are the limitations of a 2-Q drive?
A 2-Q drive cannot slow down an inertial load or reverse direction unless field reversal is used.
When are reversing (4-Q) drives recommended?
4-Q drives are used when motor torque can occur in either direction, such as for conveyors, rolling mills, or cranes.
What is the function of a 4-Q drive?
A 4-Q drive can start and stop an inertial load in both forward and reverse directions.
Which DCS800-S0x module sizes have internal field power supplies?
Converter module sizes D1 through D5 are equipped with fused internal field power supplies.
Which DCS800-S0x module sizes require an external field power supply?
Module sizes D6 and D7 require an external field power supply.
What is the permissible cooling air temperature range for the converter module?
The permissible cooling air temperature for the converter module is 0 to +55°C, but derating is required above +40°C with rated DC current.
What is the Short Circuit Current Rating (SCCR) for D1-D4 modules?
The Short Circuit Current Rating (SCCR) for DCS800-S0x modules sizes D1 through D4 is 65 kA.
What is the SCCR for D5-D7 modules?
The Short Circuit Current Rating (SCCR) for DCS800-S0x modules sizes D5 through D7 is 100 kA.