Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ACS550-U1-088A-2+B055+K454 - ACS550 AC Drive, 3-200-240V In, 30HP, 88A, Type 12/IP55, 1.1 overload, Advanced, 29.9 x 10.1 x 11.2 in, Wall, PROFIBUS DP

ABB Low Voltage Drives ACS550-U1-088A-2+B055+K454 ACS550 AC Drive, 3-200-240V In, 30HP, 88A, Type 12/IP55, 1.1 overload, Advanced, 29.9 x…

Alternate Item Number: 3AUA0000010480

UPC: 662348049518


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS550 AC Drive, SKU: ACS550-U1-088A-2+B055+K454, provides reliable motor control for industrial applications. This unit is designed for a 3-phase input voltage range of 200-240V and delivers a continuous current of 88A, suitable for motors up to 30HP. Its enclosure features an IP55 and Type 12 rating, offering protection against dust ingress and low-pressure water jets, making it appropriate for environments with moderate dust and moisture. The drive includes a 1.1 overload capacity, allowing it to handle transient motor demands. Engineered for wall mounting, its compact dimensions are 29.9 x 10.1 x 11.2 inches, facilitating installation in control cabinets or on factory floors. Integrated PROFIBUS DP communication enables straightforward integration into existing automation networks. This ABB drive offers advanced control features for enhanced motor performance and energy efficiency, contributing to operational optimization. Manufactured in Denmark, this drive is a dependable component for various industrial motor control needs.
  • 30HP, 88A, 200-240V 3-Phase AC Drive
  • IP55 / Type 12 Enclosure for dust and water protection
  • Integrated PROFIBUS DP communication for network integration
  • Wall-mount design with compact dimensions (29.9 x 10.1 x 11.2 in)
  • 1.1 overload capacity for transient motor demands

Specifications

Connection Type
PROFIBUS DP
Control Panel
Advanced
Current Rating
88A
Frame Size
R4
Input Phase
3-Phase
IP Rating
IP55
Mounting Type
Wall
Nema Rating
Type 12
Options
PROFIBUS DP
Output Current
88
Output Phase
3-Phase
Series
ACS550
Size
29.9 x 10.1 x 11.2 in
UL Type
12
Voltage
240
Voltage Range
208-240
Voltage Rating
200-240 VAC
Voltage Rating
3-200-240 VAC
Voltage Rating
3-200-240 V
Package Dimensions (L x W x H)
11.2 in x 10.1 in x 29.9 in
Package Dimensions (L x W x H)
28.448 cm x 25.654 cm x 75.946 cm
Package Weight (Imperial)
75.000 L
Package Weight (Metric)
34.020 kg
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the input voltage range for ACS550 drives?

The drives support 3-phase input voltages of 208 to 240 V, 380 to 480 V, and 500 to 600 V, with a tolerance of +10/-15%.

What is the operating ambient temperature range?

The drives can operate in ambient temperatures between 15 to 40°C (5 to 104° F).

What are the humidity requirements for operation?

The relative humidity must be lower than 95%, and condensation is not allowed.

What certifications do the ACS550 drives hold?

The drives hold UL, cUL, C-Tick, and Gost-R approvals, and are certified to seismic criteria ICC AC-156.

What is the output frequency range for motors?

The motor output frequency can be set from 0 to 500 Hz.

What communication protocols are supported?

The drives have built-in Modbus RTU protocol and support numerous internally mountable fieldbus adapters.

What protection classes are available for ACS550 drives?

The drives are available in UL Type 1, 12, or 3R (NEMA 1, 12, or 3R) enclosures.

Are coated boards available for harsh environments?

Yes, the drives are available with coated boards for use in harsh environments.

Does the drive have harmonic reduction features?

Yes, it includes a patented swinging choke for superior harmonic reduction and an integral EMC filter as standard.

What control panel features are included?

The drives feature an advanced control panel for intuitive operation and include several assistants for commissioning and maintenance.