ABB Low Voltage Drives ACS355-03U-08A8-4 ACS355 AC Drive, 3-380-480V In, 3HP, 8.8A, Type OPEN, 1.5 overload, Blank, HxWxD…
Alternate Item Number: 3AUA0000058219
UPC: 662348025093
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- ABB ACS355 AC Drive for pump and fan applications
- Voltage Rating: 380-480 VAC
- Current Rating: 8.8 A
- Compact Module Mounting Type
- IP00 Protection, NEMA Type OPEN enclosure
Specifications
2.6 | lb |
2.76 | in |
3 | HP |
3-Phase | A |
380-480 | VAC |
480 | VAC |
6.34 | in |
8.8 | A |
9.41 | in |
Amerage | 8.8 A |
Control Panel | Blank |
Frame Size | R1 |
Height | 9.41 in |
Horsepower | 3 HP |
Horsepower 10% & 50% Overload/ 1 min | 3 HP |
Input Phase | 3-Phase |
IP Rating | IP20 |
Length | 6.34 in |
Mounting | Module |
Number of Phases Input | 3 |
Number of Phases Output | 3 |
Output Current | 8.8 A |
Output Current 10% & 50% Overload/ 1 min | 8.8 A |
Output Phase | 3-Phase |
Phases | 3-Phase A |
Type | ACS355 Drive |
UL Type | OPEN |
Voltage | 480 V |
Voltage Range | 380-480 V |
Voltage Rating | 480 VAC |
Weight | 2.6 lb |
Width | 2.76 IN |
Package Dimensions (L x W x H) | 6.34 IN x 2.76 IN x 9.41 IN |
Package Dimensions (L x W x H) | 16.1036 cm x 7.0104 cm x 23.9014 cm |
Package Weight (Imperial) | 2.600 L |
Package Weight (Metric) | 1.179 kg |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What are the available AC supply voltage and power ranges?
It supports 1-phase (200-240V, 0.37-2.2kW), 3-phase (200-240V, 0.37-11kW), and 3-phase (380-480V, 0.37-22kW).
What is the operating ambient temperature range for the drive?
The drive operates in ambient temperatures from -10 to 40°C (14 to 104°F), with derating above 40°C.
How can I quickly commission the drive?
Quick commissioning is possible using application macros, panel assistants, and the FlashDrop tool for preconfiguration.
What is the overload capacity of the drive?
The drive has an overload capacity of 1.5 x I2N for 1 minute every 10 minutes, and 1.8 x I2N for 2 seconds at start.
What is the maximum output frequency for this drive?
The maximum output frequency for this drive is 600 Hz.
What types of fieldbus connections are supported?
Fieldbus connection is supported via optional modules including PROFIBUS DP, CANopen®, DeviceNetTM, Modbus, Ethernet, Profinet/etherCAT®, and LonWorks®.
What are the available protection class variants?
High protection class variants are available in IP66/IP67/UL Type 4X, which are NSF certified.
What is the Safe Torque Off function and its rating?
The Safe Torque Off function is included as standard and has a SIL 3 rating.
What are the programmable digital input capabilities?
There are five digital inputs that accept 12 to 24V, PNP and NPN, with DI5 programmable for a 0 to 16 kHz pulse train.
Can this drive control permanent magnet motors?
Yes, the drive is capable of controlling both permanent magnet and induction motors.