Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ACS355-03U-03A5-2+B063 - ACS355 AC Drive, 3-200-240V In, 0.75HP, 3.5A, Type 4X, 1.5 overload, Blank, HxWxD 12.01x7.28x11.06 in, Wall

ABB Low Voltage Drives ACS355-03U-03A5-2+B063 ACS355 AC Drive, 3-200-240V In, 0.75HP, 3.5A, Type 4X, 1.5 overload, Blank, HxWxD…

Alternate Item Number: 3AUA0000058131

UPC: 662348016565


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS355-03U-03A5-2+B063 is a compact AC drive designed for pump and fan applications, offering effortless performance without the need for high overload demand. This low voltage drive from ABB operates on an input voltage range of 200-240V and delivers a robust 0.75 horsepower output with a continuous current rating of 3.5A. Engineered for reliability, it features a Type 4X enclosure, providing protection against environmental factors. The drive's physical dimensions are 12.01 inches in height, 7.28 inches in width, and 11.06 inches in depth, making it suitable for wall-mounted installations. Its 1.5 overload capability ensures stable operation even under moderate load variations. This specific model, ACS355-03U-03A5-2+B063, is optimized for applications where consistent, efficient motor control is paramount, particularly in HVAC systems and water pumping stations. The ACS355 series is known for its user-friendly interface and straightforward setup, allowing for quick integration into existing systems. Choose the ABB ACS355 for dependable and efficient motor control in your pump and fan applications.
  • ABB ACS355 AC Drive with SKU ACS355-03U-03A5-2+B063
  • 0.75 HP motor power rating
  • 3.5A continuous current output
  • 200-240V input voltage range
  • Type 4X enclosure for environmental protection

Specifications

0.75
HP
11.06
in
12.01
in
16.98
lb
200-240
VAC
240
VAC
3-Phase
A
3.5
A
7.28
in
Amerage
3.5 A
Control Panel
Blank
Frame Size
R1
Height
12.01 in
Horsepower
0.75 HP
Horsepower 10% & 50% Overload/ 1 min
0.75 HP
Input Phase
3-Phase
IP Rating
IP66
Length
11.06 in
Mounting
Wall
Number of Phases Input
3
Number of Phases Output
3
Output Current
3.5 A
Output Current 10% & 50% Overload/ 1 min
3.5 A
Output Phase
3-Phase
Phases
3-Phase A
Type
ACS355 Drive
UL Type
4X
Voltage
240 V
Voltage Range
200-240 V
Voltage Rating
240 Vac
Weight
16.98 lb
Width
7.28 in
Package Dimensions (L x W x H)
11.06 IN x 7.28 IN x 12.01 IN
Package Dimensions (L x W x H)
28.0924 cm x 18.4912 cm x 30.5054 cm
Package Weight (Imperial)
16.980 L
Package Weight (Metric)
7.702 kg
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What are the available AC supply voltage and power ranges?

It supports 1-phase (200-240V, 0.37-2.2kW), 3-phase (200-240V, 0.37-11kW), and 3-phase (380-480V, 0.37-22kW).

What is the maximum output frequency for this drive?

The maximum output frequency for this drive is 600 Hz.

What is the operating temperature range for the drive?

The drive operates between 14 to 104°F (-10 to 40°C), with derating at 122°F (50°C).

Can this drive control permanent magnet motors?

Yes, the drive supports control for both permanent magnet and induction motors.

What is the Safe Torque Off function rating?

The Safe Torque Off function is included as standard and is rated SIL 3.

What are the available fieldbus connection options?

Fieldbus connections are available via optional modules including PROFIBUS DP, CANopen®, DeviceNetTM, Modbus, Ethernet, ProfinettherCAT®, and LonWorks®.

What is the overload capacity of the drive?

The drive has an overload capacity of 1.5 x I2N for 1 minute every 10 minutes, and 1.8 x I2N for 2 seconds at start.

What types of analog inputs are supported?

Two analog inputs are supported, selectable for voltage (0-10V) or current (0-20mA) signals.

Does the drive have a built-in brake chopper?

Yes, the drive includes a built-in brake chopper.

What is the maximum relative humidity for operation?

The drive can operate in relative humidity lower than 95%, without condensation.