nVent XR200416012 ClimaGuard Air-to-Air Heat Exchanger Indoor, XR20 4w/F 115V
UPC: 783510113360
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Filterless design eliminates routine maintenance, reduces clogging, and lowers service costs
- Advanced coil design resists contaminant buildup to maintain long-term efficiency and uptime
- Low power consumption design helps reduce operating costs across the product lifecycle
- Flexible mounting options allow installation inside or outside the enclosure with multiple connection orientations
- Optimized airflow paths ensure consistent thermal performance and maximum heat removal
- Available in 115 VAC and 230 VAC configurations for global application compatibility
- UL Type 12 and IP54 rated to protect sensitive electronics from dust and contaminants
- Easy-mount flanges for simple installation
- Every unit functionally tested before shipping
- Mounting hardware, gaskets and user manual furnished with the unit
Specifications
Application | Controls and Drives; Power Distribution |
Capacity Watts Per degr.C | 7 W |
Capacity Watts Per degr.F | 4 W |
Color | Light Gray |
Color Code | RAL 7035 |
Current Rating | 0.6 A |
Depth | 76 mm |
Depth | 3 IN |
Finish | Powder Coated |
Frequency | 60 Hz |
Frequency | 50/60Hz |
Height | 20 in |
Height | 508 mm |
Ip Rating | Type 12 |
Material | Mild Steel Sheet Metal |
Material | Mild Steel |
Max Current | 0.6 A |
Max Watts Per °F | 4 W |
Max Watts Per degr.C | 7 W |
Max Watts Per degr.F | 4 W |
Mechanical Advantage | Mild steel sheet metal standard |
Mounting Type | Easy-mount flanges |
Mounting Type | Surface-mounted |
Nema Rating | Type 12 |
NEMA Rating | 12 Indoor, dust-resistant |
Nominal Voltage | 115 V |
Number Of Phases | 1 |
Operating Temperature | -29-60 °C |
Operating Temperature | -20-140 °F |
Product Family | ClimaGuard |
Protection Rating | NEMA Type 12 |
Refrigerant | R513A |
Series | ClimaGuard XR20 |
Series | ClimaGuard |
Size | 20" H x 7.5" W x 3" D |
Thickness | 1.21 mm |
Thickness | 18 ga |
Type | Heat Exchangers |
Voltage AC | 100-120 V |
Voltage AC | 100 V |
Voltage Rating | 115V |
Voltage Rating | 115 V |
Weight | 5.4 kg |
Weight | 15 lb |
Weight | 12 lb |
Width | 191 mm |
Width | 7.5 in |
Package Dimensions (L x W x H) | 21.75 IN x 8.75 IN x 7.3 IN |
Package Dimensions (L x W x H) | 55.245 cm x 22.225 cm x 18.542 cm |
Package Weight (Imperial) | 15.000 L |
Package Weight (Metric) | 6.804 kg |

XR2926001
Heat Exchanger 230v 50/60Hz, Bulletin MCLHE (Heat exchangers - Mclean Midwest Heat Exchangers), Size/Dims: 29.00x10.00x3.13, Material: Steel, Finish: Lt Gray
HE3316101
Heat Exchanger 115v 50/60Hz, Bulletin MCLHE (Heat exchangers - Mclean Midwest Heat Exchangers), Size/Dims: 34.13x12.38x9.25, Material: Steel, Finish: Gray
HE3326101
Heat Exchanger 230v 50/60Hz, Bulletin MCLHE (Heat exchangers - Mclean Midwest Heat Exchangers), Size/Dims: 34.13x12.38x9.25, Material: Steel, Finish: Gray
XR2916001
Heat Exchanger 115v 50/60Hz, Bulletin MCLHE (Heat exchangers - Mclean Midwest Heat Exchangers), Size/Dims: 29.00x10.00x3.13, Material: Steel, Finish: Lt GrayHow to Install the XR200416012 Heat Exchanger
This guide provides step-by-step instructions for installing and configuring the XR200416012 heat exchanger for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the heat exchanger
Secure the XR200416012 heat exchanger to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached to prevent vibrations.
- Connect the power supply
Using wire strippers, prepare the power supply wires and connect them to the terminal block of the heat exchanger. Ensure that the connections are tight and secure to prevent electrical issues.
- Verify electrical connections
Use a multimeter to check the voltage at the terminal block to ensure it matches the specifications of the heat exchanger. This step is crucial for safe operation.
- Configure the settings
Refer to the user manual to set the operational parameters of the heat exchanger. Adjust settings such as temperature and fan speed according to your requirements.
- Calibrate the unit
Run the heat exchanger for a short period and monitor its performance. Make any necessary adjustments to the settings to ensure optimal operation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.