nVent UU606020 - Ultrx Enclosure Solid Door Type 4X, 600x600x200mm, Lt Gray, Fiberglass
nVent

UU606020

UPC: 783510336905


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Ultrx Enclosure UU606020 is a Type 4X solid door enclosure constructed from durable fiberglass, measuring 600x600x200mm and finished in light gray. This nonmetallic enclosure is designed for industrial applications requiring protection against dust, water, and corrosive agents, meeting NEMA Type 4X standards. Its fiberglass construction offers superior corrosion resistance compared to metal alternatives, making it suitable for harsh environments such as coastal areas, chemical processing plants, and water treatment facilities. The ULTRX series is manufactured by nVent, a recognized leader in electrical protection solutions. Key applications include outdoor electrical and control panels, telecom hubs, and transportation infrastructure. The solid door design ensures maximum protection for internal components. Installation is facilitated by pre-drilled mounting holes and a modular design. The enclosure is also rated IP66/IP67 when properly sealed, ensuring reliable performance in both indoor and outdoor settings. This product is made in the USA.
  • Compression-molded fiberglass material has excellent temperature and chemical resistance qualities and exhibits outstanding physical properties, including high-impact resistance
  • Fiberglass is easily punched, drilled, filed or sawed
  • Seamless foam-in-place gasket assures water-tight and dust-tight seal
  • Enclosure may be rotated 180 degrees for left and right hinging
  • Molded-in drip shields are standard with each enclosure
  • Impact-resistant polycarbonate window is permanently bonded in place
  • Fiberglass mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Unique hinge design allows for standard 180 degree door opening with a maximum opening of 270 degrees
  • Door hinges are replaceable
  • Type 316 stainless steel quarter-turn latch

Specifications

Application
Controls and Drives;Corrosive Environments
Application
Corrosive Environments; Controls and Drives
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Conductive Panel
A24P24G
Cubic Capacity
4858 in3
Depth
228 mm
Depth
8.98
Depth
228
Door Style
Solid
Door Type
Solid
External Dimensions
24.61 x 24.09 in
External Dimensions
625 x 612 mm
Finish
Smooth Matte
Height
625 mm
Height
24.61
Height
625
Internal Dimensions
119 x 119 x 92 mm
Internal Dimensions
23.94 x 23.43 x 8.66 in
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
22.01 x 22.52 in
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Panel
A24P24
Panel Size
20.98 x 20.98 in
Panel Size
533 x 533 mm
Product Family
Ultrx
Protection Rating
NEMA Type 12
Series
ULTRX
Size
24.61 x 24.09 in
Size
600x600x200mm
Thickness
51.40mm (2.024")
Thickness
0.15 in
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
32.4 lb
Width
24.09
Width
612
Width
612 mm
Package Dimensions (L x W x H)
29 IN x 23.8 IN x 11.4 IN
Package Dimensions (L x W x H)
73.66 cm x 60.452 cm x 28.956 cm
Package Weight (Imperial)
32.400 L
Package Weight (Metric)
14.697 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the UU606020 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the UU606020 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the UU606020 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the controller. Ensure all connections are secure to avoid electrical shorts.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is outside the specified range, recheck your connections.

  4. Configure the controller

    Follow the manufacturer's instructions to access the configuration menu. Set the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Perform calibration as per the guidelines provided in the user manual. This may involve adjusting settings based on the specific application and verifying output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.