Enhance your data center or industrial enclosure's thermal management with the nVent Express Rack Top Baffle (SKU: UACTB6A). Designed for optimal airflow control, this robust baffle is constructed from a durable Polycarbonate ABS blend, ensuring longevity and resistance to environmental factors common in IT and industrial settings. Its black finish provides a professional aesthetic that integrates seamlessly into most standard server rack and cabinet environments. The primary function of the nVent Rack Top Baffle is to prevent the recirculation of hot exhaust air back into the front of the rack, a critical step in maintaining efficient cooling and preventing equipment overheating. By strategically directing airflow, this baffle helps to create a more predictable and effective cooling zone within your enclosures, thereby improving the performance and lifespan of your sensitive electronic equipment. This is particularly important in high-density deployments where heat generation is a significant concern. This baffle is engineered for compatibility with a wide range of standard width cabinets featuring solid, perforated, or semi-solid steel tops. Its dimensions of 10.90 inches (height) x 23.60 inches (width) x 22.50 inches (depth) are designed to fit common rack footprints, offering a versatile solution for various enclosure configurations. It's important to note that this baffle is not suitable for aluminum-framed cabinets or open-framed racks, as its mounting and sealing mechanisms are optimized for solid-top enclosures. Key benefits of implementing the nVent Express Rack Top Baffle include: * **Improved Thermal Efficiency:** Significantly reduces hot air recirculation, leading to lower internal cabinet temperatures. * **Enhanced Equipment Reliability:** Protects sensitive electronics from overheating, minimizing downtime and extending operational life. * **Cost Savings:** By optimizing cooling, it can reduce the load on HVAC systems, potentially lowering energy consumption. * **Durable Construction:** Made from high-quality Polycarbonate ABS for lasting performance in demanding environments. * **Easy Integration:** Designed for straightforward installation on most standard steel-topped cabinets. When selecting a rack top baffle, professionals consider factors such as cabinet type, dimensions, airflow requirements, and material durability. The nVent brand is synonymous with quality and innovation in enclosure solutions, and the UACTB6A model upholds this reputation by offering a reliable and effective method for managing airflow within your critical infrastructure. Proper installation ensures a tight seal, maximizing the baffle's effectiveness in directing airflow away from the intake of your equipment. This product is an essential component for any organization serious about maintaining optimal operating conditions for their IT hardware and industrial control systems.
  • Allows additional natural light into aisle
  • The Rack Top Baffles require a minimum of 1 inch (25 mm) unobstructed depth across the entire front edge of the cabinet for secure attachment
  • Additionally, the two attachment fixtures on each baffle require a 1.50 x 5.50 inch (38 x 140 mm) unobstructed area on the top of the cabinet
  • These attachment mounts allow a high degree of flexibility across the top of the cabinet to work around obstructions
  • Prevents hot exhaust air from wrapping over the tops of racks
  • Attaches to top of rack magnetically
  • Angular baffle designed for cold aisle application
  • Vertical baffle is designed for hot aisle application
  • Reconfigurable design allows angular or vertical configuration
  • Tool-less Ceiling Panels are easy to install and remove for cleaning and provide above-the-cabinet access to cables, equipment and systems

Specifications

Application
Networking, Storage and Data Center; Datacom and Telecom Equipment; Telecom and Data Protection
Application
Datacom and Telecom Equipment;Networking, Storage and Data Center;Telecom and Data Protection
Color
Black;Black, Ral 9005
Color
Black
Color
Jet Black
Color Code
RAL 9005
Consist Of
Angled baffle, fits cabinet 24-inch (600mm) wide
Depth
572 mm
Depth
22.5 in
Finish
Powder Coated
Height
10.9 in
Height
44 IN
Material
Polycarbonate ABS
Material
Polycarbonate/ABS/PVC;PVC
Material
PVC
Mounting Type
Top-Mounted
Product Family
ProLine Containment System
Series
Express
Size
10.90 x 23.60 x 22.5 inch
Size
10.90x23.60x22.50 inches
Type
Aisle Containment
Weight
2 lb
Width
599 mm
Width
23.6 in
Package Dimensions (L x W x H)
23.6 IN x 10.9 IN x 22.5 IN
Package Dimensions (L x W x H)
59.944 cm x 27.686 cm x 57.15 cm
Package Weight (Imperial)
2.000 L
Package Weight (Metric)
0.907 kg
Express Rack Top Baffle, 10.90x23.60x22.50, Black, Polycarbonate PVC

UACTB6V

Express Rack Top Baffle, 10.90x23.60x22.50, Black, Polycarbonate PVC
Inspection Window 7.83 x 3.03 x 0.04"

L 10

Inspection Window 7.83 x 3.03 x 0.04"
8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8084HLL

8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet
Window Kit N4 - Viewing Area 13 x 8

1481WN41308

Window Kit N4 - Viewing Area 13 x 8
RPT8 Floor Box Duplex Insert, Material Polycarbonate

RPT8-INSERT-WHITE

RPT8 Floor Box Duplex Insert, Material Polycarbonate
Pluggable terminal blocks,pitch:5.08mm, Color:green,Contact surface :Tin

2EDGK-5.08-03P-14-1000Z(H)

Pluggable terminal blocks,pitch:5.08mm, Color:green,Contact surface :Tin
Enclosure Accessories. Enclosure Kits (with provision for CPT and/or pilot devices, lights).

CR460XE2D

Enclosure Accessories. Enclosure Kits (with provision for CPT and/or pilot devices, lights).
Plastic far side electrical box support that mounts to the back of 1-1/2 in or 2-1/8 in boxes. It is designed for 3-5/8 in steel studs and is intended for electrical box applications. The support is made of black plastic with molded construction.

DLS1

Plastic far side electrical box support that mounts to the back of 1-1/2 in or 2-1/8 in boxes. It is designed for 3-5/8 in steel studs and is intended for electrical box applications. The support is made of black plastic with molded construction.
FIXOCAP NUTS M3 AND M5 COLOR BLACK FOR ASSYMETRICAL PROFIL

58000004

FIXOCAP NUTS M3 AND M5 COLOR BLACK FOR ASSYMETRICAL PROFIL

How to Install the Rack Top Baffle Assembly (UACTB6A)

This guide provides step-by-step instructions for installing the Rack Top Baffle Assembly on IT rack cabinets using strong rare earth magnets.

Estimated time: 45m

Tools needed:

Ladder, Screwdriver

Supplies needed:

Magnet Tail Assemblies, Alignment Clips

  1. Determine the attachment position

    Inspect the top surface of the cabinet to identify the best attachment position for the Magnet Tails, avoiding any cable cutouts or obstructions.

  2. Attach the Tail Assemblies

    Position the tail assembly beneath the desired location on the extrusion base, insert the thumbscrew through the required hole, and tighten by hand. Repeat for the second tail assembly.

  3. Position the Rack Top Baffle Assembly

    Rest the front edge of the Rack Top Baffle Assembly extrusion base on the cabinet frame, keeping the magnet tails elevated. Center the assembly left to right before allowing the magnets to make contact.

  4. Continue installation along the aisle

    Place the Rack Top Baffle Assembly on top of each rack in the aisle, ensuring even gaps between the plastic panels. Use alignment clips if necessary to correct any misalignment.

  5. Engage the magnets

    Once positioned correctly, rotate the Rack Top Baffle Assembly down until the magnets click into place, securing the assembly to the rack.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.