Overview
- Registers surrounding air and can switch inductive and resistive loads via snap-action contact
- Clips for vertically mounting on 35 mm DIN rail (EN 60715)
- An integrated resistor (RF) can be connected to improve the switch temperature difference
- An integrated resistor (RF) can be connected to improve the switch temperature difference
- Integrated resistor (RF) option for improved switch temperature difference
Specifications
Application | Controls and Drives;Power Distribution |
Color | Light Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Depth | 1.5 IN |
Depth | 38 mm |
Finish | Smooth Matte |
Height | 67 mm |
Height | 2.64 in |
Material | Plastic |
Modification Services | Yes |
Type | Cooling Accessories |
Voltage AC | 230 V |
Weight | 0.1 lb |
Width | 1.97 IN |
Width | 50 mm |
Package Dimensions (L x W x H) | 2.75 IN x 2 IN x 1.75 IN |
Package Dimensions (L x W x H) | 6.985 cm x 5.08 cm x 4.445 cm |
Package Weight (Imperial) | 0.100 L |
Package Weight (Metric) | 0.045 kg |
How to Install the THERM26F Temperature Controller
This guide provides step-by-step instructions for installing and configuring the THERM26F temperature controller in an electrical cabinet.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the THERM26F controller to the upper area of the electric cabinet using the integrated clips. Ensure it is level and firmly attached, avoiding proximity to heat-generating components.
- Connect the wiring
Use heat-resistant cables if the ambient temperature exceeds 70°C (158°F). Connect the wiring to the appropriate terminals, ensuring correct polarity to avoid personal injury or equipment damage.
- Configure the temperature settings
Set the temperature on the controller, allowing for the maximum hysteresis of 5K +2/-3K. Verify the settings using a multimeter to ensure proper voltage and functionality.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.