nVent TE162048020 - Thermoelectric Cooler TE16 48V without Shroud, 15.75x7.09x7.25 Anodized Aluminum
nVent

TE162048020

UPC: 783510210649


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent TE16 Thermoelectric Cooler (SKU: TE162048020) delivers 200W of cooling power for sealed enclosures using Peltier technology, eliminating compressors, condensers, and filters for low-maintenance operation. Designed for small to medium indoor/outdoor enclosures, it maintains optimal temperatures to protect critical components in automation, telecommunications, and industrial control systems. The unit operates across a wide temperature range (-40°C to 55°C) with internal and external airflow of 62 CFM (105 M³/Hr.) and 86 CFM (146 M³/Hr.), respectively. Power consumption is 295W at 35°C, with a rated current of 7.6A at 55°C. Constructed from durable anodized aluminum, it meets UL Type 12, 3R, 4, and 4X ratings with IP65 ingress protection. Compact dimensions (15.75" H x 7.09" W x 7.25" D) and terminal block power input simplify installation. Ideal for harsh environments requiring reliable thermal management without moving parts. The TE162048020 features a 48V DC power input, ensuring compatibility with standard industrial power systems. Its anodized aluminum housing provides corrosion resistance and thermal efficiency, while the absence of a shroud allows for flexible mounting configurations. The unit’s design prioritizes durability, with a focus on long-term performance in demanding conditions where vibration, dust, and moisture resistance are critical.
  • Operates on the Peltier effect for cooling or heating
  • Contains no refrigerant, making it earth friendly
  • Filterless design reduces maintenance requirements
  • Compressor-free air conditioning for demanding indoor and outdoor applications
  • Prewired with simple terminal block for easy wiring connections
  • Shrouded and unshrouded models included in standard packages
  • Operating temperature range -40 C (-40 F) to 55 C (131 F)
  • Partial recess mount
  • DC Powered operation for 24V and 48V applications
  • Low profile design allows for mounting vertically and horizontally on any enclosure to avoid interference with internal components

Specifications

Application
Hygienic Environments; Power Distribution; Controls and Drives; Corrosive Environments
BTU Rating
567
Color
Unpainted
Current Rating
7.6 A
Depth
7.25 in
Depth
184 mm
Dimensions
15.75 x 7.09 x 7.25 in
Finish
Anodized
Height
15.75 in
Height
400 mm
Housing Material
Aluminum
IP Rating
IP65
Material
Aluminum
Material
Anodized Aluminum
Max Current
7.6 A
Nema Rating
Type 12/3R/4/4X
Nominal Capacity Btu/h
567 Btu/h
Nominal Capacity Watts
166 W
Nominal Voltage
48 V
Operating Temperature
-40-131 °F
Operating Temperature
-40-55 °C
Operating Voltage
48 VDC
Power Consumption
166 W
Protection Rating
NEMA Type 12
Series
TE16
Size
15.75x7.09x7.25 in (400x180x184 mm)
Thickness
1.52 mm
Thickness
16 ga
Type
Thermoelectric Coolers
Voltage DC
40-56.7 V
Voltage Rating
48 VDC
Weight
18.3 lb
Weight
6.7 kg
Width
180 mm
Width
7.09 IN
Package Dimensions (L x W x H)
17.8 IN x 10.2 IN x 9.6 IN
Package Dimensions (L x W x H)
45.212 cm x 25.908 cm x 24.384 cm
Package Weight (Imperial)
18.300 L
Package Weight (Metric)
8.301 kg
Thermoelectric Cooler TE12 48V without Shroud, 11.81x6.02x7.40 Anodized Aluminum

TE121048020

Thermoelectric Cooler TE12 48V without Shroud, 11.81x6.02x7.40 Anodized Aluminum

How to Install the TE162048020 Thermoelectric Cooler

This guide provides step-by-step instructions for installing and configuring the TE162048020 thermoelectric cooler, ensuring proper functionality and safety.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the cooler

    Check the thermoelectric cooler for any visible damage that may have occurred during shipping. Ensure all components are intact before proceeding.

  2. Prepare the enclosure

    Using the cutout dimensions provided in the manual, prepare the air openings and mounting bolt hole pattern on the enclosure where the cooler will be installed.

  3. Mount the cooler

    Secure the thermoelectric cooler to the enclosure using the provided mounting fasteners. Ensure it is level and firmly attached.

  4. Connect the power supply

    Refer to the nameplate for electrical requirements. Connect the thermoelectric cooler to a properly grounded power supply, ensuring that the circuit ampacity is at least 125% of the amperage specified.

  5. Test functionality

    Power on the cooler and allow it to operate for 5 to 10 minutes. Listen for any excessive noise or vibration and check that the ambient and enclosure fans are running properly.

  6. Verify connections

    Use a multimeter to verify that the voltage at the terminal block matches the specifications for the cooler's operation. Ensure all connections are secure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.