nVent TB3R103 - Terminal Box 3-Phase Type 3R, 18.00x8.00x4.50, Gray, Steel
nVent

TB3R103

UPC: 783510144449


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent TB3R103 is a 3-Phase Type 3R Terminal Box designed for outdoor commercial and industrial wire-splice applications. This 100 Amp, 600-volt enclosure facilitates feeder tap to branch circuit connections. Constructed from 16-gauge galvanized steel with an ANSI 61 gray polyester powder paint finish, it meets NEMA/EEMAC Type 3R and IEC 60529 IP32 standards, protecting against falling rain and sleet. Key features include a drip-shield top, seam-free sides, front, and back for enhanced weather resistance. The removable cover ensures easy installation and maintenance. Integrated distribution lugs simplify wiring, and provisions for padlocking or sealing offer security. Bottom knockouts allow for convenient cable entry, and built-in grounding provisions ensure electrical safety. With dimensions of 18.00x8.00x4.50 inches, the TB3R103 provides ample space for terminations. It is UL 50, UL 1773, and CSA C22.2 No. 94 listed, ensuring reliability for power distribution, motor control, and general electrical infrastructure in manufacturing plants, utility substations, and commercial facilities. SKU: TB3R103.
  • Grounding provisions
  • Hub opening at top with cover
  • Provisions for padlocking or seal
  • Distribution lugs installed (see table for sizes)
  • Knockouts on bottom of enclosure
  • Removable cover
  • Drip-shield top and seam-free sides, front and back
  • Terminal Boxes are finished with paint over plated surfaces

Specifications

Amps
100 A
Application
Power Distribution
Bar Quantity
4
Color
Gray
Color Code
ANSI 61
Connection Type
Screw Terminal
Current
100-100 A
Current Rating
100 A
Depth
4.5
Depth
114
Depth
13 IN
Finish
Galvanized
Height
44 IN
Height
18
Height
457
IP Rating
IP32
Material
Steel
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Mounting Type
Wall Mount
NEMA Rating
Type 3R
NEMA Rating
3R Weather-resistant, except dust
NEMA Rating
3r
Number of Phases
3 Ph
Phase
3Ø Ph
Poles
3-Phase
Protection Rating
NEMA Type 3R
Series
nVent 3R Steel Terminal Box
Size
18.00x8.00x4.50 in
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Utility Cabinets
Type
Utility / Canadian Cabinets and Splitters
Type Number
Type 3R
Voltage AC
600 V
Voltage Rating
600 V
Weight
15.8 lb
Width
8
Width
203
Width
23 IN
Wire Range
(6) #14-2/0 kcmil
Wire Size
(6) #14 - 2/0
Package Dimensions (L x W x H)
18.9 IN x 12.6 IN x 7 IN
Package Dimensions (L x W x H)
48.006 cm x 32.004 cm x 17.78 cm
Package Weight (Imperial)
15.800 L
Package Weight (Metric)
7.167 kg
Terminal Box 3-Phase Type 3R, 18.00x10.75x4.50, Gray, Steel

TB3R103240

Terminal Box 3-Phase Type 3R, 18.00x10.75x4.50, Gray, Steel

How to Install the TB3R103 Terminal Box

This guide provides step-by-step instructions for installing and configuring the TB3R103 Terminal Box for outdoor commercial and industrial applications.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the terminal box

    Secure the TB3R103 terminal box to the designated mounting surface using the provided mounting screws. Ensure the box is level and firmly attached.

  2. Connect the wiring

    Open the terminal box cover and connect the incoming feeder wires to the distribution lugs inside the box. Use terminal connectors as necessary to ensure secure connections.

  3. Verify electrical connections

    Use a multimeter to check the voltage at the distribution lugs to ensure proper electrical connections. Confirm that the voltage matches the specifications for the TB3R103.

  4. Seal and secure the cover

    Once all connections are verified, replace the terminal box cover and ensure it is securely fastened. Consider using a padlock or seal for added security.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.