Authorized nVent Distributor
nVent T200246G401 - T-Series Compact Outdoor T20, 2000BTU 460V, Brushed, SS304

nVent T200246G401 T-Series Compact Outdoor T20, 2000BTU 460V, Brushed, SS304

UPC: 783510243043


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent T-Series Compact Outdoor T20 (SKU: T200246G401)** delivers 2000 BTU of cooling at 460V, 50/60Hz, single-phase for outdoor industrial applications. Its compact design fits tight spaces like control panels, electrical enclosures, or small outdoor shelters without sacrificing cooling capacity. The T20 is optimized for manufacturing plants, oil and gas facilities, telecom sites, and renewable energy installations where outdoor electronics require climate protection. Key features include corrosion-resistant components, compressor heaters for cold climates, and head pressure controls for consistent performance across ambient temperature fluctuations. The unit’s stainless steel construction resists rust, salt spray, and chemical exposure, ensuring long-term reliability in extreme conditions. With a single-phase power requirement and 460V compatibility, it integrates seamlessly into global industrial electrical systems. Ideal for protecting sensitive equipment in refineries, pipelines, offshore platforms, network cabinets, and traffic control systems.
  • Compact footprint to minimize real estate and maximize capacity
  • Models for 115, 230 and 460 VAC power input
  • Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C
  • UL Listed to save customers time and money with agency approvals (some models UL recognized)
  • Painted galvanized or stainless steel sheet-metal cover for rugged factory and outdoor environments
  • Reliable mechanical thermostat on enclosure side of the unit
  • Dual condenser-side air movers for performance redundancy
  • Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
  • Exterior and fully recessed mounting options on many models
  • Easy-mount flanges for simple installation

Specifications

Application
Controls and Drives;Corrosive Environments;Power Distribution
Application
Corrosive Environments; Power Distribution; Controls and Drives
Color
Unpainted
Color
Brushed
Depth
9.9 in
Depth
251 mm
Finish
Brushed #3
Frequency
50/60 Hz
Height
616 mm
Height
24.25 in
Material
Stainless Steel 304
Material
SS304
Max Current
1.9 A
NEMA Rating
4X Watertight, corrosion-resistant
Nominal Capacity Btu/h
2,000 Btu/h
Nominal Capacity Watts
586 W
Nominal Voltage
460 V
Number Of Phases
1
Operating Temperature
-40-55
Operating Temperature
-40-131 °F
Operating Temperature
-40-55 °C
Outdoor Installation
Yes
Poles
1PH
Product Family
T-Series
Protection Rating
NEMA Type 4X
Refrigerant
R134a
Remote Access Control
No
Series
T-Series Compact Outdoor
Series
T-Series
Size
Compact
Thickness
1.21 mm
Thickness
18 ga
Thickness
51.40mm (2.024")
Type
Air Conditioners
Voltage AC
400-460 V
Voltage Rating
400 - 460 VAC
Voltage Rating
460 V
Weight
30 kg
Weight
60 lb
Width
254 mm
Width
10 IN
Package Dimensions (L x W x H)
14.75 IN x 11.75 IN x 28 IN
Package Dimensions (L x W x H)
37.465 cm x 29.845 cm x 71.12 cm
Package Weight (Imperial)
60.000 L
Package Weight (Metric)
27.216 kg
SpectraCool Narrow Indoor/Outdoor AC, 2000BTU 460V, Brushed, SS304

N210246G051

SpectraCool Narrow Indoor/Outdoor AC, 2000BTU 460V, Brushed, SS304
DTS 3081 115V Type 4/4X 304 SS

13382344300

DTS 3081 115V Type 4/4X 304 SS
AC Unit 4,000 BTU/H 230 V - NEMA 4x - 304 SS

DTS3181A230N4SS

AC Unit 4,000 BTU/H 230 V - NEMA 4x - 304 SS
InRow RC 300mm Chilled Water

ACRC301S

InRow RC 300mm Chilled Water
SpectraCool Narrow Hazardous Location AC, 6000BTU 460V, Brushed, SS316

NHZ360646G400

SpectraCool Narrow Hazardous Location AC, 6000BTU 460V, Brushed, SS316
SpectraCool Narrow Hazardous Location AC, 8000BTU 230V, Brushed, SS316

NHZ360826G400

SpectraCool Narrow Hazardous Location AC, 8000BTU 230V, Brushed, SS316
SpectraCool Narrow Hazardous Location AC, 8000BTU 460V, Brushed, SS316

NHZ360846G400

SpectraCool Narrow Hazardous Location AC, 8000BTU 460V, Brushed, SS316
SpectraCool Narrow Hazardous Location AC, 11000BTU 115V, Brushed, SS316

NHZ431216G400

SpectraCool Narrow Hazardous Location AC, 11000BTU 115V, Brushed, SS316

How to Install the T200246G401 Air Conditioner

Installation guide for mounting and wiring the T200246G401 air conditioner.

Estimated time: 45m

Tools needed:

Screwdriver, Wrench, Ratchet driver

Supplies needed:

Gasket kit, 1/4-20x.625 mounting bolts, Power cord or wiring

  1. Verify Functionality

    Inspect the air conditioner and verify correct functionality before mounting. If the air conditioner has been in a horizontal position, ensure it has been upright for at least 5 minutes before operating. Connect to a properly grounded power supply and run for 5-10 minutes, checking for excessive noise or vibration. Ensure the condenser blower, evaporator blower, and compressor are running.

  2. Prepare Enclosure

    Determine if the unit will be surface or recess mounted. Prepare the enclosure opening using the appropriate cutout dimensions from the manual. Ensure adequate ventilation and clearance around the installation location (24" front, 2" sides, 6" top, 9" bottom). Maintain at least 3" clearance between the air conditioner and other internal components.

  3. Install Gaskets and Mount Unit

    Install the provided gasket kit to the air conditioner. Mount the air conditioner onto the enclosure using the 1/4-20x.625 mounting bolts. Use the "EZ" mount tabs to hold the unit in place while mounting. Start bolts by hand before tightening with a wrench or ratchet driver to a torque of 65 in./lbs. Ensure the unit remains upright.

  4. Route Drain Tube

    Route the drain tube ensuring it has a continuous downward slope to prevent kinking or elevation above the exit point. Failure to do so may result in overflowing the condensate drain pan.

  5. Connect Power

    Refer to the top of the nameplate for electrical requirements. Connect the power cord or wire the unit to a properly grounded power supply, following applicable national wiring regulations. If wiring directly, use a slow blow time delay fuse or HACR circuit breaker rated per the MOPD rating.

  6. Adjust Temperature Setting (Optional)

    If necessary, adjust the temperature setting. Remove the nylon plug from the front face of the unit. Use a standard screwdriver to turn the adjustment screw clockwise for cooler settings or counterclockwise for warmer settings. Reinstall the nylon plugs.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.