nVent T150126G120 T-Series Compact Outdoor Indoor T15, 800BTU 230V, Lt Gray, Steel
UPC: 783510143039
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Compact footprint to minimize real estate and maximize capacity
- Models for 115, 230 and 460 VAC power input
- Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C
- UL Listed to save customers time and money with agency approvals (some models UL recognized)
- Painted galvanized or stainless steel sheet-metal cover for rugged factory and outdoor environments
- Reliable mechanical thermostat on enclosure side of the unit
- Dual condenser-side air movers for performance redundancy
- Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
- Exterior and fully recessed mounting options on many models
- Easy-mount flanges for simple installation
Specifications
Amperage Rating | 1.4;1.5 A;A |
Amperage Rating | 1.4/1.5 A |
Application | Controls and Drives;Power Distribution |
Btu Rating | 800 |
Color | Light Gray |
Color | Gray |
Color Code | RAL 7035 |
Current Rating | 1.5 A |
Depth | 160 mm |
Depth | 6.3 in |
Finish | Powder Coated |
Frequency | 60 Hz |
Frequency | 50/60 Hz |
Frequency Rating | 50/60 Hz |
Frequency Rating, Maximum | 60 Hz |
Frequency Rating, Minimum | 50 Hz |
Height | 15.75 in |
Height | 400 mm |
Material | Galvanized Steel |
Material | Mild Steel |
Material | Steel |
Max Current | 1.5 A |
Mounting Type | Side Mounting |
Nema Rating | Type 12, 3R, 4 (Type 4X optional) |
NEMA Rating | 12 Indoor, dust-resistant |
Nominal Capacity Btu/h | 900 Btu/h |
Nominal Capacity Watts | 264 W |
Nominal Voltage | 230 V |
Number Of Phases | 1 |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-131 °F |
Operating Temperature | 131 Deg F @ 60 Hz |
Operating Temperature | -40-55 |
Outdoor Installation | No |
Phase | 1 Ph |
Phase | 1 |
Product Family | T-Series |
Protection Rating | NEMA Type 12 |
Refrigerant | R134a |
Remote Access Control | No |
Series | T-Series |
Series | T-Series T15 |
Size | 800BTU |
Size | 15.75" H x 7.5" W x 6.3" D |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 200-250 V |
Voltage Rating | 220/230 V |
Voltage Rating | 230 V |
Weight | 27.3 lb |
Weight | 12 kg |
Width | 7.5 in |
Width | 191 mm |
Package Dimensions (L x W x H) | 11.2 IN x 9.9 IN x 18.8 IN |
Package Dimensions (L x W x H) | 28.448 cm x 25.146 cm x 47.752 cm |
Package Weight (Imperial) | 27.300 L |
Package Weight (Metric) | 12.383 kg |

M521046G002
AC, 3Phase 460v 50/60Hz, Bulletin MCL (Air Conditioners - M52-1046 --H), Size/Dims: 8000/10000 BTU, Material: Steel, Finish: Lt Gray
M520846G002
AC, 3Phase 460v 50/60Hz, Bulletin MCL (Air Conditioners), Size/Dims: 6500/7500 BTU, Material/Finish: Steel/LtGray
M520446G002
AC, 3Phase 460v 50/60Hz, Bulletin MCL (Air Conditioners), Size/Dims: 3800/4100 BTU, Material/Finish: Steel/LtGray
CR430826G002O
The nVent CR430826G002O is a high-performance cable management solution designed for industrial applications requiring durability and reliability. Engineered to withstand harsh environments, this product ensures secure and organized wiring, reducing downtime and improving operational efficiency. Its robust construction and precision engineering make it ideal for use in manufacturing, automation, and other demanding industrial settings. Trust nVent for superior cable management solutions that meet the highest industry standards.Frequently Asked Questions
What voltage does the T150126G120 require?
The air conditioner operates on 230V AC with a frequency of 50/60 Hz and single-phase power.
What is the operating temperature range for this unit?
The T150126G120 operates effectively in ambient temperatures from -40°F to 131°F (-40°C to 55°C).
What are the dimensions of the T15 air conditioner?
The compact unit measures 15.75 inches in height, 7.5 inches in width, and 6.3 inches in depth.
What thermostat is included with the T15?
The unit includes an electromechanical thermostat factory preset to 75°F (23°C) located on the enclosure side.
Does the T15 include any redundancy features?
Yes, the unit features dual condenser-side air movers for performance redundancy.
How to Install the T150126G120 Air Conditioner
Installation guide for mounting and wiring the T150126G120 air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Gasket kit, Mounting bolts, Mounting screws, Drain tube
- Inspect and Test the Air Conditioner
Inspect the air conditioner for any shipping damage. If the unit has been in a horizontal position, ensure it is placed in an upright position for a minimum of five (5) minutes before operating. Test the air conditioner by connecting the power cord to a properly grounded power supply and operating it for five to ten minutes. Ensure there is no excessive noise or vibration, and that the condenser blower, evaporator blower, and compressor are running. Condenser air temperatures should be warmer than normal room temperatures within a few minutes. Refer to the nameplate for proper electrical current requirements. Minimum circuit ampacity should be at least 125% of the amperage shown in the design data section for the appropriate model. No other equipment should be connected to this circuit to prevent overloading.
- Prepare the Enclosure
Using the cutout dimensions provided in the manual, prepare the air "IN" and air "OUT" openings, and the mounting bolt hole pattern for the enclosure.
- Install Gaskets
Using the provided gasket kit, install gaskets to the air conditioner.
- Mount the Air Conditioner
Mount the air conditioner onto the enclosure using the provided mounting bolts and screws. "EZ" mount tabs can be used to hold the unit in place while mounting. Ensure the unit remains upright for a minimum of five (5) minutes before starting. Start bolts by hand before tightening with a wrench or ratchet driver to avoid cross-threading mounting inserts.
- Route the Drain Tube
When routing the drain tube, ensure it is on a continuous downward slope and does not kink or elevate above the exit point of the air conditioner. Failure to follow these instructions could result in overflowing of the condensate drain pan.
- Connect Power
Refer to the top of the nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. Use of an extension cord is not recommended. The electrical circuit should be fused with a slow blow or HACR circuit breaker.
- Adjust Temperature Setting
To change the temperature setting, remove the nylon plug from the front face of the unit. Use a standard screwdriver to adjust the thermostat. Turn clockwise for cooler temperatures and counterclockwise for warmer temperatures. The dial range of the thermostat is 50-95 F.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.