Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- To attach hinges, holes must be drilled in the cover
- Templates are provided for proper placement
- Integral weld studs and compression clips for secure mounting
- Oil-resistant neoprene gasket for watertight seal
- Meets UL/CSA Type 12 and Type 4 standards
Specifications
Application | Controls and Drives; Corrosive Environments |
Color | Unpainted |
Finish | Transparent |
Material | Polycarbonate |
Type | Other Accessories |
Works With | NEMA |
Frequently Asked Questions
What is the SW64 NEMA Window Kit made of?
The SW64 NEMA Window Kit is made of polycarbonate material.
What is the finish of the SW64 NEMA Window Kit?
The SW64 NEMA Window Kit has a transparent, unpainted finish.
What is the purpose of the VM Hinged Window Kits?
VM Hinged Window Kits allow adding a window to opaque VJ Enclosure covers.
How are hinges attached to the VJ Enclosure cover for the window kit?
Holes must be drilled in the cover to attach the hinges for the VM Hinged Window Kits.
Are templates provided for installing the SW64 window kit?
Yes, templates are provided for proper placement when installing the window kit.
How to Install the SW64 Enclosure
Guide for mounting and preparing the SW64 enclosure for use. Ensure proper installation for optimal performance and safety.
Estimated time: 30m
Tools needed:
Screwdriver, Drill (if mounting holes are not pre-drilled), Level
Supplies needed:
Mounting screws, Wire connectors, Air vents (if not included)
- Select Mounting Location
Choose a suitable location for the SW64 enclosure. Consider environmental factors and accessibility for maintenance. Ensure the mounting surface is stable and can support the weight of the enclosure and its contents. Refer to the datasheet for specific environmental ratings and limitations.
- Prepare the Enclosure
If required, install air vents for proper circulation. Two air vents should be installed, ideally in the upper and lower parts of the enclosure, to prevent condensation. Refer to the specific part number for air vent installation instructions and required hardware.
- Mount the Enclosure
Securely mount the SW64 enclosure to the chosen surface using appropriate mounting screws. Ensure the enclosure is level and firmly attached. For enclosures with molded mounting flanges, align these with the mounting surface and fasten securely. Verify that the enclosure meets the required NEMA/EEMAC or IP ratings for the intended environment.
- Wiring and Connections
Open the enclosure and proceed with internal wiring and connections as per your application requirements. Ensure all electrical connections are made in accordance with local codes and standards. For specific wiring details or internal component compatibility, consult the product's datasheet.
- Final Inspection and Closure
After completing all internal installations and wiring, perform a final inspection to ensure all components are securely fastened and all connections are correct. Close and secure the enclosure cover, ensuring the gasket provides a proper seal. Verify that all latches or screws are tightened appropriately.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.