nVent SQDC - Operator Adapter Universal Cutout, Square D Cable Oper, Gray, Steel
nVent

SQDC

UPC: 783510280987


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent HOFFMAN SQDC Operator Adapter is engineered for seamless integration of Square D® Class 9422 Flex-cable Mechanisms into nVent HOFFMAN Type 4 and 12 disconnect enclosures featuring a universal flange cutout. This adapter is essential for installing disconnects in specific HOFFMAN enclosure bulletins, including A21, A28, A34, and A4L3D, when equipped with a universal cutout. The SQDC kit includes the necessary adapter plate and additional components required to interlock the enclosure's master door with the disconnect operating mechanism, ensuring safe and compliant operation. Installation instructions are provided with each adapter. It is crucial to select the correct operator adapter for each specific brand and type of disconnect. For disconnect switches rated 400A or greater, or circuit breakers rated 600A or greater, a large handle is required. Conversely, disconnect switches rated 200A or less, and circuit breakers rated 400A or less, require a small handle. The SQDC is manufactured in the US and is constructed from durable steel with a gray finish. SKU: SQDC. UNSPSC Code: 39121321.
  • Used on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout
  • An operator adapter is required to install a disconnect in Bulletin A21, A28, A34, A35 and A4L3D HOFFMAN enclosures that have a universal cutout
  • Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism
  • Installation instructions are included with each operator adapter
  • Each brand and type of disconnect requires a different operator adapter
  • A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle
  • A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle

Specifications

Accessory Type
Mounting Accessories
Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Power Distribution; Arc Flash Safety; Controls and Drives
Color
Gray
Color Code
ANSI 61
Consist Of
Operator Adapter
Depth
0.5 in
Depth
13 mm
Finish
Powder Coated
Height
44 IN
Height
10.56 in
Material
Mild Steel
Modification Services
Yes
Thickness
2.66 mm
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
Other Accessories
Weight
1.5 lb
Width
62 mm
Width
2.44 IN
Works With
NEMA
Package Dimensions (L x W x H)
4.5 IN x 3.5 IN x 20 IN
Package Dimensions (L x W x H)
11.43 cm x 8.89 cm x 50.8 cm
Package Weight (Imperial)
1.500 L
Package Weight (Metric)
0.680 kg
Operator Adapter Universal Cutout, GE Cable Oper, Gray, Steel

GEC

Operator Adapter Universal Cutout, GE Cable Oper, Gray, Steel
Pole Mount Kit for 24 x 24 enclosure

APMK24

Pole Mount Kit for 24 x 24 enclosure
Gland plate Gray for 11.75 x 2.31 opening - Steel/Lt Gray

GP134LG

Gland plate Gray for 11.75 x 2.31 opening - Steel/Lt Gray
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder

AB253

The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
Feed through Terminal Blocks

DS1.5-QU-01P-11-00Z(H)

Feed through Terminal Blocks
This RC50 connector is a non-metallic electrical box accessory for NM cable securement. It is gray in color and finish, with a 1/2" size and a 2-5/8" length. The connector has a tapered point, 3 flutes, a 1-3/8" thread length, and National Coarse 1/4"-20 threading.

RC50

This RC50 connector is a non-metallic electrical box accessory for NM cable securement. It is gray in color and finish, with a 1/2" size and a 2-5/8" length. The connector has a tapered point, 3 flutes, a 1-3/8" thread length, and National Coarse 1/4"-20 threading.
Old Work Box Support Clip. Clips Lock Old-Work Steel Switch Boxes Tightly To Wall Plaster, Dry Wall, Concrete Block, Brick Or Concrete. Adapts To Any Wall Thickness Up To 3/4 Inch

OWC

Old Work Box Support Clip. Clips Lock Old-Work Steel Switch Boxes Tightly To Wall Plaster, Dry Wall, Concrete Block, Brick Or Concrete. Adapts To Any Wall Thickness Up To 3/4 Inch
STEEL SQUARES 25X25X19 WITH HOLES 7MM

50000045

STEEL SQUARES 25X25X19 WITH HOLES 7MM
8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8084HLL

8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet
Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

SBL300

Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

How to Install the SQDC Operator Adapter

This guide provides step-by-step instructions for installing the SQDC Operator Adapter for Square 'D' Bulletin 9422 Flexible Cable Operating Mechanisms.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Plate gasket, Nylon washers, Flat washers, Lockwashers, Hex nuts

  1. Install the mounting plate

    Secure the mounting plate and plate gasket inside the enclosure behind the rectangular opening. Use four screws and four nylon washers to secure it in place.

  2. Assemble the operating handle

    Attach the Square 'D' operating handle and cable handle mechanism to the mounting plate. Omit the cap screw and lockwasher that fits into the bottom hole of the operating handle.

  3. Install the slide arm

    Position the slide arm over the handle assembly with the notch facing the door opening. Insert the shoulder collar through the oval slot in the slide arm and secure it with the long cap screw and lockwasher.

  4. Connect the slide arm to the lock release mechanism

    Attach the bottom of the slide arm to the offset arm of the lock release mechanism using two flat washers, two lockwashers, and two hex nuts. Do not tighten yet.

  5. Adjust the safety lock release mechanism

    Check and adjust the roller bracket on the enclosure to ensure the door latch hits the latch stop when closed. Adjust the slide arm length so the safety lock releases just before the master door is fully latched.

  6. Install the door catch

    Attach the door catch to the tapped spacer on the door using the bottom set of mounting holes with two screws and lockwashers.

  7. Drill and tap holes for the switch

    Drill and tap holes in the panel according to Square 'D' instructions for proper switch mounting.

  8. Mount the switch or circuit breaker

    Follow the Square 'D' instructions to mount the switch or circuit breaker securely.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.