nVent SPD2006 - Separation Plates for MCS MCD Enclosures, SPD, 2000x13x600mm, Zinc Plated, Steel
nVent

SPD2006

UPC: 783510528362


Documents & Media
Installation InstructionsVideo Clip

Contact for Pricing

Overview

Enhance your industrial enclosure system with the nVent SPD Separation Plate (SKU: SPD2006), meticulously engineered for MCS and MCD floor-standing enclosures. This robust separation plate, constructed from 1.5 mm zinc-plated steel, is designed to effectively divide bayed enclosures, creating distinct compartments for organized component mounting and improved system management. By installing the SPD2006, you ensure that each section of your bayed enclosure system maintains its integrity, crucial for protecting sensitive electrical and electronic equipment. This separation plate is a vital accessory for any application requiring the division of space within a larger enclosure configuration. It plays a key role in maintaining the overall environmental protection of the enclosure system, especially when combined with optional sealing gaskets. For achieving IP 43 and TYPE 1 sealing, the SPDG gasket is recommended, ensuring dust and water ingress protection. Furthermore, for applications demanding electromagnetic interference (EMI) shielding, the SPDEG gasket can be utilized, providing an additional layer of protection for critical components. The nVent SPD2006 is designed for straightforward integration into your existing or new enclosure setup. It requires CCJ brackets for secure mounting within the enclosures. When baying enclosures together, complementary brackets such as CCM and CCI are necessary to ensure a secure and stable configuration. The durable zinc-plated steel construction offers excellent corrosion resistance, ensuring longevity and reliable performance even in demanding industrial environments. Key benefits of the nVent SPD Separation Plate include: * **Enhanced Organization:** Creates individual zones within bayed enclosures, facilitating better cable management and component segregation. * **Maintained IP Rating:** Contributes to preserving the enclosure's ingress protection when used with appropriate sealing accessories. * **Component Protection:** Isolates components, reducing the risk of interference and improving system reliability. * **Durable Construction:** Made from 1.5 mm zinc-plated steel for superior strength and corrosion resistance. * **Versatile Application:** Ideal for a wide range of industrial applications, including manufacturing facilities, data centers, and power distribution systems. When specifying separation plates for your nVent MCS or MCD enclosures, the SPD2006 offers a precise fit for 2000mm high and 600mm deep configurations. Trust in nVent's commitment to quality and innovation to deliver solutions that meet the rigorous demands of industrial environments. Ensure your electrical infrastructure is organized, protected, and optimized with nVent accessories.
  • Description: Separates two bayed MCS/MCD enclosures.
  • Material: 1.5 mm zinc plated steel.
  • Mounting requirements: IP 43 and TYPE 1 sealing can be obtained by using SPDG gasket. CCJ brackets are required to mount the SPD into the enclosures. To bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used.
  • Pack quantity: 1 piece.
  • Benefit: these areas are commonly used to group component types, for example power in one section and control in another
  • Benefit: these spaces can also be used when some components are more sensitive to temperature than others, allowing better control of the enclosure's thermal management
  • Comment: separation brackets, CCJ, are required in order to mount the separation plate; if the separation plate is mounted within an enclosure assembly, the internal corner baying kit, CCM, and external baying brackets, CCI, should be used
  • Mounting the separation gasket, SPDG, will increase the protection degree on either side of the plate to IP 43; the separation plate cannot be mounted within stainless steel enclosures
  • Mounting requirements: IP 43, TYPE 1 sealing can be obtained by using SPDG gasket and CCJ brackets are required to mount the SPD into the enclosures
  • Mounting requirements: to bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used

Specifications

Application
Controls and Drives; Factory Automation and Process Control
Color
Unpainted
Consist of
Separation Plates for MCS, MCD Enclosures; Mounting Components and Instruction Manual
Construction
16 gauge
Depth
19.92 in
Depth
506 mm
Enclosure Material
Mild Steel
Finish
Zinc Plated
Height
78.74 in
Height
2,000 mm
Height
1,918 mm
Material
Mild Steel
Package Quantity
1
Size
75.51 x 0.49 x 19.92 inch
Thickness
1.5 mm
Thickness
16 ga
Type
Baying
Type
IEC Enclosure Accessories
Weight
27.13 lb
Weight
12.3 kg
Weight
27.12 lb
Width
0.49 in
Width
13 mm
Width
0.51 in
Works With
IEC
Package Dimensions (L x W x H)
79.12 IN x 24 IN x 8 IN
Package Dimensions (L x W x H)
200.9648 cm x 60.96 cm x 20.32 cm
Package Weight (Imperial)
27.130 L
Package Weight (Metric)
12.306 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the SPD2006 Surge Protective Device

This guide provides step-by-step instructions for installing and configuring the SPD2006 Surge Protective Device, ensuring proper mounting, wiring, and calibration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Torque wrench

Supplies needed:

Mounting screws (M5x10), Terminal connectors, Internal baying brackets

  1. Prepare the installation site

    Ensure the installation area is clean and free of debris. Verify that the mounting surface can support the weight of the SPD2006.

  2. Mount the SPD2006

    Attach the internal baying brackets to the mounting surface using M5x10 screws. Secure the SPD2006 to the DIN rail using the integrated clips, ensuring it is level and firmly attached.

  3. Connect the wiring

    Use wire strippers to prepare the wires for connection. Connect the input and output terminals of the SPD2006 using appropriate terminal connectors, ensuring all connections are tight and secure.

  4. Torque the connections

    Using a torque wrench, apply a torque of 4-5.5 Nm to the terminal connections to ensure they are properly secured.

  5. Verify the installation

    Use a multimeter to check the voltage levels at the input and output terminals. Ensure that the readings are within the specified range for the SPD2006.

  6. Calibrate the device

    Follow the manufacturer's instructions to configure any necessary settings on the SPD2006. Ensure that all parameters are set according to the installation requirements.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.