Overview

The nVent SPD2004 is a Type 1+2 AC surge protection device designed for 230/400V AC networks, offering 40kA maximum discharge current (10/350μs) and 20kA nominal discharge current (8/20μs). Engineered for incoming panels and service entrance applications, it protects against indirect lightning strikes and switching surges in low-voltage electrical installations. The device features a voltage protection level (Up) of ≤1.5kV, response time (ta) of ≤25ns, and operates reliably in ambient temperatures from -40°C to 80°C. With IP20 protection and compliance to IEC/EN 61643-11 Type 1+2 and IEC/EN 61643-21 Class I+II standards, the SPD2004 ensures robust performance in TT and TN-S, TN-C-S systems. Its pluggable module design allows for easy replacement, while the remote signaling contact provides status indication. The thermoplastic housing measures 108mm (W) x 83.1mm (H) x 90mm (L) and mounts on a 35mm DIN rail, supporting rigid 4-35mm² or flexible 4-25mm² conductors. Ideal for industrial, commercial, and utility applications requiring surge protection at the service entrance.
  • Description: Separates two bayed MCS/MCD enclosures.
  • Material: 1.5 mm zinc plated steel.
  • Mounting requirements: IP 43 and TYPE 1 sealing can be obtained by using SPDG gasket. CCJ brackets are required to mount the SPD into the enclosures. To bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used.
  • Pack quantity: 1 piece.
  • Benefit: these areas are commonly used to group component types, for example power in one section and control in another
  • Benefit: these spaces can also be used when some components are more sensitive to temperature than others, allowing better control of the enclosure's thermal management
  • Comment: separation brackets, CCJ, are required in order to mount the separation plate; if the separation plate is mounted within an enclosure assembly, the internal corner baying kit, CCM, and external baying brackets, CCI, should be used
  • Mounting the separation gasket, SPDG, will increase the protection degree on either side of the plate to IP 43; the separation plate cannot be mounted within stainless steel enclosures
  • Mounting requirements: IP 43, TYPE 1 sealing can be obtained by using SPDG gasket and CCJ brackets are required to mount the SPD into the enclosures
  • Mounting requirements: to bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used

Specifications

Application
Factory Automation and Process Control; Controls and Drives
Color
Unpainted
Consist of
Separation Plates for MCS, MCD Enclosures; Mounting Components and Instruction Manual
Construction
16 gauge
Depth
306 mm
Depth
12.05 in
Enclosure Material
Mild Steel
Finish
Zinc Plated
Height
78.74 in
Height
2,000 mm
Height
1,918 mm
Material
Mild Steel
Package Quantity
1
Size
75.51 x 0.49 x 12.05 inch
Thickness
1.5 mm
Thickness
16 ga
Type
Baying
Type
IEC Enclosure Accessories
Weight
16.4 lb
Weight
7.45 kg
Weight
16.42 lb
Width
0.49 in
Width
13 mm
Width
0.51 in
Works With
IEC
Package Weight (Imperial)
16.400 L
Package Weight (Metric)
7.439 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the SPD2005 Surge Protective Device

This guide provides step-by-step instructions for mounting, wiring, and configuring the SPD2005 Surge Protective Device.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Drill

Supplies needed:

Mounting screws (M5x10, M6x12), Terminal connectors, Internal baying brackets

  1. Prepare the installation area

    Ensure the installation area is clean and free of obstructions. Verify that the mounting surface can support the weight of the SPD2005.

  2. Mount the internal baying brackets

    Install the internal baying brackets according to the provided specifications. If using CCM, remove CCI from corners before mounting.

  3. Secure the SPD2005 to the mounting surface

    Attach the SPD2005 to the DIN rail using the integrated clips. Ensure it is level and securely fastened.

  4. Connect the wiring

    Use terminal connectors to wire the SPD2005 according to the wiring diagram. Ensure all connections are tight and secure.

  5. Verify the connections

    Use a multimeter to check the continuity of the connections. Ensure there are no short circuits before powering on.

  6. Power on the SPD2005

    Turn on the power supply to the SPD2005 and monitor for any irregularities. Ensure the device operates within specified parameters.

  7. Calibrate the device

    Follow the calibration procedure as outlined in the user manual to ensure optimal performance of the SPD2005.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.