Contact for Pricing
Overview
- Description: Separates two bayed MCS/MCD enclosures.
- Material: 1.5 mm zinc plated steel.
- Mounting requirements: IP 43 and TYPE 1 sealing can be obtained by using SPDG gasket. CCJ brackets are required to mount the SPD into the enclosures. To bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used.
- Pack quantity: 1 piece.
- Benefit: these areas are commonly used to group component types, for example power in one section and control in another
- Benefit: these spaces can also be used when some components are more sensitive to temperature than others, allowing better control of the enclosure's thermal management
- Comment: separation brackets, CCJ, are required in order to mount the separation plate; if the separation plate is mounted within an enclosure assembly, the internal corner baying kit, CCM, and external baying brackets, CCI, should be used
- Mounting the separation gasket, SPDG, will increase the protection degree on either side of the plate to IP 43; the separation plate cannot be mounted within stainless steel enclosures
- Mounting requirements: IP 43, TYPE 1 sealing can be obtained by using SPDG gasket and CCJ brackets are required to mount the SPD into the enclosures
- Mounting requirements: to bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used
Specifications
Application | Factory Automation and Process Control; Controls and Drives |
Color | Unpainted |
Consist of | Separation Plates for MCS, MCD Enclosures; Mounting Components and Instruction Manual |
Construction | 16 gauge |
Depth | 506 mm |
Depth | 19.92 in |
Enclosure Material | Mild Steel |
Finish | Zinc Plated |
Height | 70.87 in |
Height | 1,718 mm |
Height | 1,800 mm |
Ip Rating | IP43 (with optional SPDG gasket) |
Material | Mild Steel |
Material | Steel |
Material | Steel, Zinc Plated |
Mounting Type | Bayed Enclosure Separation |
Mounting Type | Mounted with CCJ brackets |
Package Quantity | 1 |
Series | SPD |
Size | 67.64 x 0.49 x 19.92 inch |
Size | 1800x13x600mm |
Thickness | 1.5 mm |
Thickness | 16 ga |
Type | Baying |
Type | IEC Enclosure Accessories |
Weight | 10.8 kg |
Weight | 23.82 lb |
Weight | 23.81 lb |
Width | 0.49 in |
Width | 13 mm |
Width | 0.51 in |
Works With | IEC |
Package Dimensions (L x W x H) | 71.24 IN x 24 IN x 8 IN |
Package Dimensions (L x W x H) | 180.9496 cm x 60.96 cm x 20.32 cm |
Package Weight (Imperial) | 23.820 L |
Package Weight (Metric) | 10.805 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the SPD1806 Surge Protective Device
This guide provides step-by-step instructions for installing and configuring the SPD1806 Surge Protective Device on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter, Drill
Supplies needed:
Mounting screws (M5x10), Terminal connectors, Internal baying brackets
- Prepare the installation area
Ensure the installation area is clean and free of debris. Identify the location for mounting the SPD1806 on the DIN rail.
- Mount the internal baying brackets
Install the internal baying brackets before mounting the SPD1806. Use M6x12 screws and torque them to 4-5.5 Nm.
- Secure the SPD1806 to the DIN rail
Attach the SPD1806 to the DIN rail using the integrated clips. Ensure it is level and securely fastened.
- Connect the wiring
Use terminal connectors to connect the SPD1806 to the electrical system. Ensure all connections are tight and secure.
- Verify the installation
Use a multimeter to check the connections and ensure proper voltage levels. Confirm that the SPD1806 is functioning correctly.
- Calibrate the device
Follow the manufacturer's instructions to configure any necessary settings on the SPD1806 for optimal performance.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.