Authorized nVent Distributor
nVent SPD1805 - Separation Plates for MCS MCD Enclosures, SPD, 1800x13x500mm, Zinc Plated, Steel

nVent SPD1805 Separation Plates for MCS MCD Enclosures, SPD, 1800x13x500mm, Zinc Plated, Steel

UPC: 783510528324


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent SPD1805 is a 1.5 mm thick, zinc-plated steel separation plate designed for use with nVent MCS and MCD enclosures. This plate effectively separates bayed enclosures, creating distinct compartments for component mounting while maintaining the enclosure's integrity. Measuring 1800mm in height and 500mm in width, it is constructed from mild steel with a durable zinc-plated finish for corrosion resistance. The SPD1805 requires CCJ mounting brackets for installation into the enclosures. To achieve IP43 and Type 1 sealing, the SPDG gasket is recommended. For enhanced protection and EMI shielding, the SPDEG gasket can be utilized. When baying enclosures together, CCM and CCI brackets are necessary. This separation plate is suitable for industrial, commercial, and data center applications where component segregation and environmental protection are critical. Each unit is supplied as a single piece. The SPD1805 is part of the SPD series, offering a practical solution for managing internal enclosure space and environmental sealing.
  • Description: Separates two bayed MCS/MCD enclosures.
  • Material: 1.5 mm zinc plated steel.
  • Mounting requirements: IP 43 and TYPE 1 sealing can be obtained by using SPDG gasket. CCJ brackets are required to mount the SPD into the enclosures. To bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used.
  • Pack quantity: 1 piece.
  • Benefit: these areas are commonly used to group component types, for example power in one section and control in another
  • Benefit: these spaces can also be used when some components are more sensitive to temperature than others, allowing better control of the enclosure's thermal management
  • Comment: separation brackets, CCJ, are required in order to mount the separation plate; if the separation plate is mounted within an enclosure assembly, the internal corner baying kit, CCM, and external baying brackets, CCI, should be used
  • Mounting the separation gasket, SPDG, will increase the protection degree on either side of the plate to IP 43; the separation plate cannot be mounted within stainless steel enclosures
  • Mounting requirements: IP 43, TYPE 1 sealing can be obtained by using SPDG gasket and CCJ brackets are required to mount the SPD into the enclosures
  • Mounting requirements: to bay enclosures together, use CCM and CCI brackets. For EMI shielding the SPDEG gasket must be used

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Application
Factory Automation and Process Control; Controls and Drives
Color
Unpainted
Consist of
Mounting Components and Instruction Manual;Separation Plates for MCS, MCD Enclosures
Consist of
Separation Plates for MCS, MCD Enclosures; Mounting Components and Instruction Manual
Construction
16 gauge
Depth
406 mm
Depth
15.98 in
Enclosure Material
Mild Steel
Finish
Zinc Plated
Height
70.87 in
Height
1,800 mm
Height
67.64 in
Ip Rating
IP rating maintained
Material
Steel
Material
Mild Steel
Package Quantity
1
Series
SPD
Size
67.64 x 0.49 x 15.98 inch
Size
1800x13x500 mm
Thickness
51.40mm (2.024")
Thickness
16 ga
Thickness
1.5 mm
Type
Baying
Type
IEC Enclosure Accessories
Weight
8.85 kg
Weight
19.51 lb
Weight
32 lbs./100ft
Weight
19.52 lb
Width
0.51 in
Width
13 mm
Width
0.49 in
Works With
IEC
Package Dimensions (L x W x H)
71.24 IN x 20.06 IN x 8 IN
Package Dimensions (L x W x H)
180.9496 cm x 50.9524 cm x 20.32 cm
Package Weight (Imperial)
19.520 L
Package Weight (Metric)
8.854 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the SPD1805 separation plate made of?

The separation plate is made of 1.5 mm zinc-plated steel.

What are the dimensions of the SPD1805 separation plate?

The separation plate measures 70.87 inches in height, 0.51 inches in width, and 15.98 inches in depth.

What is the finish of the SPD1805 separation plate?

The finish of the separation plate is zinc plated.

What is the thickness of the SPD1805 separation plate?

The thickness of the separation plate is 16ga.

What is the weight of the SPD1805 separation plate?

The weight of the separation plate is 19.51lb.

What is the enclosure material for the SPD1805?

The enclosure material is mild steel.

What brackets are needed to mount the SPD1805 into enclosures?

CCJ brackets are required to mount the SPD into the enclosures.

What is required to bay enclosures together using this plate?

To bay enclosures together, CCM and CCI brackets are required.

How is the IP rating maintained with the separation plate?

An IP 43 and TYPE 1 sealing can be obtained by using the SPDG gasket.

How can EMI shielding be achieved with the separation plate?

For EMI shielding, the SPDEG gasket must be used.

How to Install the SPD1805 Surge Protective Device

This guide provides step-by-step instructions for installing and configuring the SPD1805 Surge Protective Device on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Drill

Supplies needed:

Mounting screws (M5x10, M6x12), Terminal connectors, Internal baying brackets

  1. Prepare the installation area

    Ensure the installation area is clean and free of obstructions. Verify that the DIN rail is securely mounted and can support the weight of the SPD1805.

  2. Mount the internal baying brackets

    Install the internal baying brackets before mounting the SPD1805. Use M6x12 screws and torque them to 4-5.5 Nm. If using CCM, ensure that CCI is removed from the corners.

  3. Attach the SPD1805 to the DIN rail

    Securely attach the SPD1805 to the DIN rail using the integrated clips. Ensure it is level and firmly attached.

  4. Connect the wiring

    Use terminal connectors to connect the SPD1805 to the electrical system. Ensure all connections are tight and secure.

  5. Verify the installation

    Use a multimeter to check the voltage levels and ensure the SPD1805 is functioning correctly. Confirm that all connections are secure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.