Contact for Pricing
Overview
- Set screws are provided with system couplings, not the tubes
- Tubes 750 mm and longer include drilling template to assist with drilling and tapping the holes when the tube is cut to length
- Assembled Syspend 281 HMI Arm System has a max weight load of 281 lb. (127.7 kg)
- Includes drilling template for custom length modifications (for tubes 750mm and longer).
- Supports up to 281 lb (127.7 kg) at 3.3 ft (1 m) as part of the Syspend 281-Max system.
Specifications
Application | Controls and Drives |
Color | Unpainted |
Depth | 49.21 |
Depth | 1,250 |
Depth | 1,250 mm |
Finish | Anodized |
Height | 3.54 |
Height | 90 |
Height | 90 mm |
Material | Anodized Aluminum |
Material | Aluminum |
Modification Services | Yes |
Mounting Type | Set screws (6 per end) |
Product Family | Syspend 281-Max |
Protection Rating | IP65 |
Series | Syspend 281-Max |
Size | 3.15x4.13x50.39 in |
Size | 70 x 90 mm (cross-section) |
Thickness | 0.24 in |
Thickness | 6 mm |
Type | Syspend 281-Max |
Weight | 15 lb |
Width | 2.76 |
Width | 70 |
Width | 70 mm |
Package Dimensions (L x W x H) | 50 IN x 4.25 IN x 3.25 IN |
Package Dimensions (L x W x H) | 127 cm x 10.795 cm x 8.255 cm |
Package Weight (Imperial) | 15.000 L |
Package Weight (Metric) | 6.804 kg |
How to Install the S2MT1250 Suspension System
This guide provides step-by-step instructions for installing the S2MT1250 suspension system, including mounting, wiring, and initial configuration.
Estimated time: 1h
Tools needed:
Screwdriver, Torque wrench, Wire strippers
Supplies needed:
Mounting screws, Gaskets, Terminal connectors
- Mount the tube
Secure the tube to the mounting surface using the provided screws. Ensure the screws are tightened to a torque of 20 Nm.
- Align the tube
Check the alignment of the tube by ensuring that the gap does not exceed 4.4 mm. Adjust as necessary by loosening and retightening the screws.
- Connect the wiring
Strip the ends of the wires and connect them to the terminal connectors. Ensure all connections are secure and insulated to prevent short circuits.
- Configure the system
Follow the manufacturer's instructions to configure the system settings, including any necessary programming for operation.
- Calibrate the system
Perform a calibration of the system by adjusting the settings as per the operational requirements. Verify the calibration using a multimeter.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.