Contact for Pricing
Overview
- 30A, 120/208 VAC, 3-phase power distribution
- 48 total outlets: 24 C13 and 24 CX receptacles
- L2130P twist-lock plug for secure connection
- Ultra-low 50mm profile maximizes rack space
- Supports 50/60 Hz operation for global compatibility
- iPDU DC power redundancy solution for up to 64 PDU's
- Toolless Hot-Swap Controller
- Input Voltage Range 100-120/200-240 VAC, 3-phase WYE
- Connecting cable 6", with NEMA L21 connector
- C13 and C13/C19 Combo outlets
Specifications
Application | Networking, Storage and Data Center; Telecom and Data Protection; Datacom and Telecom Equipment |
Color | Black |
Connection Type | L2130P |
Current Rating | 30 A |
Depth | 75 mm |
Frequency | 50/60 Hz |
Function | Input Monitored |
Length | 1,780 |
Product Type | Socket Strip |
Series | RackPower iPDU |
Size | 50 mm height |
Socket Type | IEC C13 |
Type | Socket Strips |
Voltage AC | 208 V |
Voltage Rating | 120/208 VAC |
Width | 56 |
With Switch | Yes |
Package Dimensions (L x W x H) | 78 IN x 9 IN x 5 IN |
Package Dimensions (L x W x H) | 198.12 cm x 22.86 cm x 12.7 cm |
Package Weight (Imperial) | 24.000 L |
Package Weight (Metric) | 10.886 kg |

P16B41M
This Panduit G5 Basic PDU features (16) 5-20R outlets. It is a 30 amp, 120 V, single phase PDU with a NEMA L5-30P input plug and a 10 foot (3m) power cord. The PDU is black.How to Install the nVent RackPower PDU
This guide provides step-by-step instructions for installing and configuring the nVent RackPower PDU, ensuring proper power distribution for your IT equipment.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Power cable
- Unpack the PDU
Carefully open the shipping carton and remove the PDU. Inspect for any damage and save the packaging material for potential returns.
- Mount the PDU
Secure the PDU to the server cabinet using the provided mounting screws. Ensure it is level and firmly attached.
- Connect to Power Source
Connect the PDU to a dedicated power source using the appropriate power cable. Ensure the connection is secure and complies with local electrical codes.
- Connect to Network
Use an Ethernet cable to connect the PDU to your network. Ensure the connection is made to the primary network port for proper functionality.
- Power On the PDU
Turn on the power supply to the PDU and check the LED indicators for proper operation. Ensure there are no alarms displayed.
- Configure Network Settings
Access the PDU's web interface using a browser. Configure the network settings, including IP address, subnet mask, and gateway as per your network requirements.
- Calibrate the PDU
Verify the calibration settings through the OLED display. Adjust any parameters as necessary to ensure accurate power monitoring.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.