Contact for Pricing
Overview
- 230V AC, 1-phase input with inlet metering for real-time power tracking
- Remote outlet switching for device power cycling and management
- Ultra-compact 50mm profile for space-constrained racks
- Modular configurations with customizable outlet types and mounting options
- SNMP, Modbus, or HTTP-based monitoring for DCIM/BMS integration
- Supports SNMP, Modbus, or HTTP monitoring protocols
- Tool-less mounting for quick and easy installation
- Input Voltage Range 200 - 240 VAC, 1-phase L-N
- Connecting cable 3 m, with IEC 60309 332P6 connector
- C13, C19 outlets
Specifications
Application | Datacom and Telecom Equipment; Telecom and Data Protection; Networking, Storage and Data Center |
Color | Black |
Depth | 53 mm |
Function | Input Monitored |
Length | 1,750 |
Mounting Type | Tool-less installation |
Number of Sockets | 24 |
Poles | 1-Phase |
Product Type | Socket Strip |
Series | RackPower iPDU |
Size | 50mm |
Socket Type | IEC C13 |
Type | Socket Strips |
Voltage AC | 230 V |
Voltage Rating | 230 VAC |
Width | 52 |
With Switch | Yes |
Package Dimensions (L x W x H) | 78 IN x 8 IN x 4.5 IN |
Package Dimensions (L x W x H) | 198.12 cm x 20.32 cm x 11.43 cm |
Package Weight (Imperial) | 15.000 L |
Package Weight (Metric) | 6.804 kg |

P12B34M
This Panduit G5 Basic PDU features (12) C13 outlets. It is a 16 amp, 230 V, single phase PDU with an IEC 60309 2P+E 6h 16A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.How to Install the nVent RackPower PDU
This guide provides step-by-step instructions for installing and configuring the nVent RackPower PDU, ensuring a reliable power distribution setup.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Unpack the PDU
Carefully open the shipping carton and remove the PDU. Inspect for any visible damage and retain the packaging for potential returns.
- Mount the PDU
Secure the PDU to the server cabinet or DIN rail using the provided mounting screws. Ensure it is level and firmly attached.
- Connect to Power Source
Connect the PDU to a dedicated power source using the appropriate power cable. Ensure the connection is secure and complies with local electrical codes.
- Connect to Network
Use an Ethernet cable to connect the PDU to your network. Ensure the connection is stable and that the network settings are configured as per your requirements.
- Initial Configuration
Power on the PDU and access the user interface. Follow the on-screen instructions to configure network settings, including IP address and SNMP settings.
- Calibrate and Test
Use a multimeter to verify the output voltage at the PDU outlets. Ensure all connections are functioning correctly and that the PDU is operating within specified parameters.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.