Overview

The nVent **PT105 Solid Top** is a precision-engineered enclosure closure designed to securely seal the top opening of industrial-grade frames measuring 1000x500mm. Manufactured by nVent, a global leader in thermal management and electrical protection solutions, this solid top combines durability with electromagnetic compatibility (EMC) compliance, making it an essential component for sensitive electronic environments. The painted finish over plated surfaces ensures long-lasting corrosion resistance, while the integrated gasketing provides environmental sealing against dust, moisture, and contaminants. Ground studs are pre-installed for seamless electrical bonding, and the included bolts (with optional lifting eyes) simplify installation and maintenance access. Whether used in control panels, telecommunications hubs, or industrial automation systems, the PT105 delivers reliable performance where protection and compliance are critical. **Key Features and Benefits:** - **EMC-Compliant Design:** The PT105 is engineered to meet stringent electromagnetic compatibility standards, preventing interference in sensitive electronic systems. This is particularly vital in industries such as manufacturing, data centers, and healthcare, where signal integrity is paramount. - **Durable Painted Finish:** The top surface is coated with a high-quality paint over plated materials, ensuring resistance to chipping, scratching, and environmental degradation. This finish also enhances aesthetic consistency in multi-unit installations. - **Integrated Gasketing:** A factory-installed gasket provides a tight seal against the enclosure frame, protecting internal components from dust, water ingress (IP54-rated when properly installed), and other airborne particulates. This is critical for outdoor enclosures or harsh industrial environments. - **Ground Studs for Safety:** Pre-installed ground studs facilitate quick and secure electrical bonding, reducing installation time and ensuring compliance with safety regulations such as NEC and IEC standards. This feature is indispensable in high-voltage or high-current applications. - **Versatile Mounting Options:** The PT105 includes bolts for standard installation, but lifting eyes can be substituted for applications requiring frequent access or overhead mounting. This flexibility streamlines both initial setup and ongoing maintenance. **Typical Applications:** The PT105 Solid Top is widely used across industries where enclosure protection and EMC compliance are non-negotiable. In **industrial automation**, it safeguards PLCs, motor drives, and variable frequency drives (VFDs) from electromagnetic interference while maintaining a sealed environment. **Telecommunications** providers rely on it to protect sensitive networking equipment in data centers and cell towers, where signal integrity is critical. The **energy sector**—including oil and gas, renewable energy, and utilities—uses these tops to shield control panels and switchgear from harsh outdoor conditions. Additionally, the PT105 is a popular choice in **medical equipment** enclosures, where regulatory compliance and contamination control are top priorities. **Why Choose nVent?** As a trusted manufacturer with decades of expertise in thermal and electrical management, nVent (formerly part of Pentair Thermal Management) delivers products that meet the rigorous demands of industrial professionals. The PT105 reflects nVent’s commitment to innovation, safety, and reliability, with features that simplify installation while maximizing performance. Backed by comprehensive technical support and a global distribution network, nVent ensures that the PT105 Solid Top is not just a component but a long-term solution for your enclosure needs. Whether you’re retrofitting an existing system or designing a new installation, the PT105 provides the protection, compliance, and durability required for mission-critical applications.
  • Solid Tops are finished with paint over plated surfaces
  • Solid Tops are gasketed and include ground studs
  • Bolts are included to hold the top in place (lifting eyes can be used instead of bolts)
  • Pre-installed ground studs for electrical bonding and safety compliance
  • Includes bolts; lifting eyes optional for versatile mounting

Specifications

Application
Controls and Drives; Power Distribution
Color
Painted
Color
Light Gray
Color Code
RAL 7035
Fits Frame
1000 x 500 mm
Frame Type
Single-Bay
IP Rating
IP55
IP Rating
IP54
Material
Mild Steel
Material
Plated with Painted Finish
Material
Metal
Modification Services
Yes
Mounting Type
Bolts with optional lifting eyes
Product Family
ProLine
Series
nVent PT Series
Series
PT Series
Size
fits 1000x500mm
Size
1000x500mm
Thickness
16 ga
Thickness
1.52 mm
Type
Steel
Weight
17 lb
Package Dimensions (L x W x H)
39.5 IN x 33.25 IN x 1.25 IN
Package Dimensions (L x W x H)
100.33 cm x 84.455 cm x 3.175 cm
Package Weight (Imperial)
17.000 L
Package Weight (Metric)
7.711 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PT105 Controller

Complete installation guide for mounting and wiring the PT105 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PT105 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the PT105 controller. Verify that the connections are secure.

  3. Configure the controller settings

    Power on the PT105 controller and use the interface to navigate to the configuration menu. Set the required parameters according to your application needs.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure accurate readings. Use a multimeter to verify output signals during calibration.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.