Authorized nVent Distributor
nVent PPOD20106 - ProLine Industrial Packages Type 12 2-Dr, 2000x1000x600, Lt Gray, Steel

nVent PPOD20106 ProLine Industrial Packages Type 12 2-Dr, 2000x1000x600, Lt Gray, Steel

UPC: 783510198039


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine Industrial Package (SKU: PPOD20106) is a fully integrated, Type 12-rated enclosure designed to streamline industrial control panel installations. Engineered for durability and compliance, this 2000x1000x600mm enclosure delivers a complete, ready-to-use solution that eliminates the need for separate component sourcing. Built by nVent, a global leader in thermal management and electrical solutions, this enclosure combines robust construction with intelligent design to meet the demands of modern industrial environments. Type 12 enclosures are engineered to protect electrical components from dust, dirt, and non-corrosive liquids while providing a secure, tamper-resistant housing for sensitive control systems. The PPOD20106 features a light gray steel construction with a solid door, handle, and key lock for enhanced security, along with a solid top and rear cover to ensure comprehensive protection. The included full mounting subpanel simplifies internal component organization, while the gland plate accommodates cable entry points without compromising enclosure integrity. Four integrated lifting eyes facilitate safe and efficient handling during installation or relocation. Designed for flexibility, this ProLine package allows side covers to be ordered separately, enabling seamless integration into multi-enclosure baying applications. This modular approach supports scalable control panel architectures, making it ideal for facilities requiring expandable infrastructure. The enclosure’s dimensions (2000x1000x600mm) provide ample internal space for housing PLCs, motor controllers, variable frequency drives (VFDs), and other critical automation components, while its compact footprint optimizes floor space utilization in control rooms or industrial cabinets. Industries such as manufacturing, oil & gas, water treatment, and renewable energy rely on Type 12 enclosures like the PPOD20106 to safeguard electrical systems in harsh or hazardous environments. Whether deployed in a factory automation line, a wastewater processing plant, or a solar farm, this enclosure ensures reliable performance under demanding conditions. nVent’s reputation for engineering excellence—backed by decades of innovation in thermal and electrical solutions—positions the ProLine series as a trusted choice for engineers and facility managers seeking dependable, code-compliant enclosures. Installation is straightforward thanks to the pre-assembled design and standardized mounting features. The subpanel is pre-drilled for quick component attachment, while the gland plate supports multiple cable entry options to accommodate various wiring configurations. For applications requiring NEMA Type 12 compliance (IP54 equivalent), this enclosure meets stringent industry standards for ingress protection, ensuring long-term reliability in dusty or damp environments. Maintenance is simplified by the removable rear cover and modular side panels, allowing for easy access to internal components without disrupting the overall system. Choose the nVent ProLine Industrial Package (PPOD20106) for a hassle-free, high-performance enclosure solution that reduces procurement complexity and accelerates project timelines. With its combination of durability, security, and scalability, this enclosure is an investment in operational efficiency and system longevity.
  • Type 12-rated enclosure (NEMA 12 equivalent) for dust and liquid protection
  • 2000x1000x600mm dimensions with light gray steel construction
  • Includes solid door, handle, key lock, top, rear cover, mounting subpanel, gland plate, and lifting eyes
  • Modular design with optional side covers for baying applications
  • Pre-drilled subpanel and gland plate for simplified installation
  • Galvanized mounting plates
  • Capped ground studs on door, rear and top panel
  • Integral frame channels support the full weight of the mounting plates
  • Frame thickness 12 gauge/2.5 mm carbon steel powder painted in RAL 7035
  • Door thickness 14 gauge/2.0 mm, carbon steel powder painted – for details please check reference tables

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
23.62
Depth
600
Finish
Powder Coated
Height
78.74
Height
2,000
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting Type
Floor Mount
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
Product Family
ProLine
Protection Rating
NEMA Type 12
Series
ProLine
Size
2000x1000x600 mm
Type
Overlapping Double Doors
Weight
383 lb
Width
39.37
Width
1,000
Package Dimensions (L x W x H)
47 IN x 31 IN x 80 IN
Package Dimensions (L x W x H)
119.38 cm x 78.74 cm x 203.2 cm
Package Weight (Imperial)
383.000 L
Package Weight (Metric)
173.729 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Safely Handle and Install a Hoffman Enclosure

Follow these instructions for the safe handling and installation of your Hoffman enclosure. Always prioritize safety and refer to the nameplate or datasheet for specific model information.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)

Supplies needed:

Mounting screws, ROLL•A•LIFT™ or similar device

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. If using a forklift, know its safe lifting capabilities and ensure it can handle the enclosure's weight and size. Always use both forks and position the enclosure far back on the forks, keeping the load against the carriage and tilting the load backwards towards the mast.

  3. Secure Enclosure for Transport

    If using a forklift, secure the enclosure to the forklift mast using a 3000 lb-rated chain or strap through the provided eye bolts. Ensure sufficient tension to prevent tipping. If using an overhead lifting device, attach rigging to eye bolts, maintaining a maximum 45° angle between lifting cables and the vertical. Use slings with adequate load-rated hooks or shackles, not ropes or cables.

  4. Move the Enclosure

    Start and stop the forklift slowly and gradually. Drive slowly with the forks as low to the ground as possible. For overhead lifting, select or adjust rigging lengths to compensate for any unequal weight distribution and support the enclosure in an upright position. Do not attempt to lift the enclosure completely off the ground if using a forklift with a clamping device.

  5. Position the Enclosure

    Carefully position the enclosure on the forks or in its final location. Ensure it is stable and does not contact fixed objects. If using a ROLL•A•LIFT™ or similar device for multi-door enclosures, place it under one end and lift that end slightly while the forklift handles the other.

  6. Final Installation Checks

    Verify that the enclosure is level, firmly installed, and all safety precautions have been followed. Re-check tension on any securing chains or straps. Refer to the nameplate or datasheet for any model-specific installation details not covered here.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.