nVent PP20106 ProLine Industrial Packages Type 12, 2000x1000x600, Lt Gray, Steel
UPC: 783510142162
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Type 12 rated steel enclosure for industrial control and automation
- Dimensions: 2000x1000x600mm (HxWxD)
- Includes frame, door(s) with key lock, subpanel, gland plate, and lifting eyes
- Simplifies procurement with a single part number (SKU: PP20106)
- IP55 IEC/VDE compliant for dust and water protection
- Galvanized mounting plates
- Capped ground studs on door, rear and top panel
- Integral frame channels support the full weight of the mounting plates
- Frame thickness 12 gauge/2.5 mm carbon steel powder painted in RAL 7035
- Door thickness 14 gauge/2.0 mm, carbon steel powder painted – for details please check reference tables
Specifications
Application | Power Distribution; Controls and Drives |
Color | Light Gray |
Color | Lt Gray |
Color Code | RAL 7035 |
Depth | 23.62 |
Depth | 600 |
Finish | Powder Coated |
Height | 78.74 |
Height | 2,000 |
Material | Mild Steel |
Material | Steel |
Modification Services | Yes |
NEMA Rating | 12 Indoor, dust-resistant |
Nema Rating | Type 12 |
Product Family | ProLine |
Protection Rating | NEMA Type 12 |
Series | ProLine Industrial Packages |
Size | 2000x1000x600 mm |
Type | Single Door |
Weight | 378 lb |
Width | 39.37 |
Width | 1,000 |
Package Dimensions (L x W x H) | 48 IN x 30 IN x 84 IN |
Package Dimensions (L x W x H) | 121.92 cm x 76.2 cm x 213.36 cm |
Package Weight (Imperial) | 378.000 L |
Package Weight (Metric) | 171.461 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Safely Handle and Install a Hoffman Enclosure
Follow these instructions for the safe handling and installation of your Hoffman enclosure. Always prioritize safety and refer to the nameplate or datasheet for specific model information.
Estimated time: 1h
Tools needed:
Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)
Supplies needed:
Mounting screws, ROLL•A•LIFT™ or similar device
- Read Safe Handling Requirements
Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.
- Prepare for Movement
Ensure the enclosure is stabilized before removing any strapping. If using a forklift, know its safe lifting capabilities and ensure it can handle the enclosure's weight and size. Always use both forks and position the enclosure far back on the forks, keeping the load against the carriage and tilting the load backwards towards the mast.
- Secure Enclosure for Transport
If using a forklift, secure the enclosure to the forklift mast using a 3000 lb-rated chain or strap through the provided eye bolts. Ensure sufficient tension to prevent tipping. If using an overhead lifting device, attach rigging to eye bolts, maintaining a maximum 45° angle between lifting cables and the vertical. Use slings with adequate load-rated hooks or shackles, not ropes or cables.
- Move the Enclosure
Start and stop the forklift slowly and gradually. Drive slowly with the forks as low to the ground as possible. For overhead lifting, select or adjust rigging lengths to compensate for any unequal weight distribution and support the enclosure in an upright position. Do not attempt to lift the enclosure completely off the ground if using a forklift with a clamping device.
- Position the Enclosure
Carefully position the enclosure on the forks or in its final location. Ensure it is stable and does not contact fixed objects. If using a ROLL•A•LIFT™ or similar device for multi-door enclosures, place it under one end and lift that end slightly while the forklift handles the other.
- Final Installation Checks
Verify that the enclosure is level, firmly installed, and all safety precautions have been followed. Re-check tension on any securing chains or straps. Refer to the nameplate or datasheet for any model-specific installation details not covered here.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.