nVent PJLBSS - Lifting Angles, fits Side /Side
nVent

PJLBSS

UPC: 783510226398


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent PJLBSS Lifting Angles (SKU: PJLBSS) are designed for secure side-to-side overhead lifting of nVent modular enclosures. This set includes two plated mild steel angles (10 gauge / 3.0mm) and mounting hardware. Each angle supports a load rating of 1500 lb (680 kg), with the set of two supporting up to 3000 lb (1360 kg) total. They are engineered for lifting ganged enclosures (two or three joined units), effectively distributing loads for up to 1000 lb (453 kg) of equipment and cabling per bay. Installation is straightforward, mounting to the top of enclosure frame corner blocks without requiring top cover removal. Use in conjunction with shackles and a spreader bar, ensuring the lifting sling or chain angle is at least 45 degrees from the enclosure top. Compliance with OSHA, ASME, ISA, ASTM, and other governing agencies for slings and spreader bars is required.
  • Used to provide best load distribution while lifting two or three ganged enclosures with up to 1000 lb. of equipment and cabling in each bay.
  • Angles mount to top of enclosure frame corner blocks and do not require removal of top cover for installation.
  • Kit consists of two angles, four hex cap screws and four washers.
  • Lifting Angles are designed for overhead lifting in conjunction with shackles and a spreader bar. Use of shackles instead of hooks is preferred. The angle between the top of the enclosure and the cable or chain must be at least 45°. Use only slings and sp
  • Supports up to 1000 lb (453 kg) of equipment and cabling per bay
  • Compliant with OSHA, ASME, ISA, ASTM, and other regulatory standards
  • Manufactured in the USA by nVent, a leader in industrial electrical solutions

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Zinc Plated
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
Side-to-side mounting on enclosure frame corner blocks
Product Family
ProLine
Series
nVent Lifting Angles
Size
Fits 1200x400mm enclosures
Thickness
10 ga
Thickness
3.4 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
3 lb
Package Dimensions (L x W x H)
11 IN x 9 IN x 3 IN
Package Dimensions (L x W x H)
27.94 cm x 22.86 cm x 7.62 cm
Package Weight (Imperial)
3.000 L
Package Weight (Metric)
1.361 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PJLBSS Cabinet

This guide provides step-by-step instructions for securely mounting and wiring the PJLBSS cabinet to ensure safe and efficient operation.

Estimated time: 45m

Tools needed:

Screwdriver, Torque wrench, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Lock washers, Joining kits (PJ2FHF2, PJ2FBF)

  1. Mount the cabinet

    Secure the cabinet to the mounting surface using the provided mounting screws and lock washers. Ensure that all fasteners are torqued to 30 in-lbs to prevent loosening.

  2. Install joining kits

    If using multiple cabinets, install the joining kits (catalog number PJ2FHF2 for side-to-side or PJ2FBF for front-to-back) between each enclosure to ensure stability and prevent separation during lifting.

  3. Verify installation

    Check that all fasteners are securely tightened and that the cabinet is level. Use a multimeter to ensure that all electrical connections are properly made and functioning before powering on the system.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.