The nVent ProLine Gland Plate (SKU: PGPV68) is a crucial component for industrial enclosure cable management, designed to maintain NEMA Type 12 integrity while facilitating efficient cable entry. This specific model is engineered for 600x800mm enclosure dimensions and features a painted, filtered design, ensuring both environmental protection and a clean internal enclosure environment. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this gland plate exemplifies robust construction and thoughtful engineering. Constructed from durable 14-gauge (1.75 mm) mild steel with a standard RAL 7035 textured light grey polyester powder paint finish, this gland plate is built to withstand demanding industrial conditions. Its primary function is to provide a sealed interface for cables entering the enclosure, preventing the ingress of dust, moisture, and other contaminants that could compromise sensitive electrical equipment. The filtered design actively contributes to maintaining a clean internal atmosphere, which is critical for the longevity and reliable operation of electrical and electronic components. This ProLine Gland Plate is designed for versatile integration with various nVent ProLine G2 base systems, including the 100 mm Solid Plinth Base, 100 mm or 200 mm Plinth Base, Mobile Base, and Transportation Base. Furthermore, it offers flexibility by allowing installation without a dedicated base when casters, levelers, or frame feet are utilized, simplifying installation and adapting to diverse site requirements. The ability to rotate the gland plate 180 degrees enhances its adaptability, allowing for either front or rear cable entry as dictated by the installation layout. Key features include: * **Sealed NEMA Type 12 Rating:** Ensures protection against dust and falling dirt, and is suitable for the eventual formation of ice on the outside of the enclosure. * **Filtered Design:** Actively manages airflow and prevents particulate ingress. * **Robust Construction:** Made from 14-gauge mild steel for superior durability. * **Adjustable Foam Gasketing:** Permits precise cable entry and maintains seal integrity. * **Versatile Mounting Options:** Compatible with various ProLine G2 bases or directly with casters, levelers, or frame feet. * **180-Degree Rotation:** Offers flexible cable entry orientation. * **All Installation Hardware Included:** Streamlines the setup process. This nVent ProLine Gland Plate is an essential accessory for any industrial application requiring secure, clean, and organized cable management within an enclosure. Its robust design and NEMA 12 rating make it ideal for use in manufacturing facilities, automation systems, data centers, and any environment where reliable protection of electrical components is paramount. The inclusion of additional foam gasketing provides further customization for cable density and access points, ensuring a perfect fit for specific wiring configurations.
  • Solid Gland Plate and EMC Gland Plate are accessories to 100- mm Solid Base, 100-mm/200-mm Plinth Base, Mobile Base and Transportation Base. These gland plates can be used without a base if casters, levelers or frame feet are installed.
  • Solid Gland Plate: the Solid Gland Plate can be used with all ProLine subpanels or rack angles. The gland plate consists of a base mounting surface and two adjustable foam-gasketed plates that permit cable entry. The plate can be rotated 180 degrees for f
  • EMC Gland Plate: This gland plate can be used with subpanels or rack angles. Gland plate consists of a base mounting surface and two adjustable gland plates (both have a conductive coating) with conductive fabric-over-foam gasket for cable entry.
  • Filtered (Vented) Gland Plate: Filtered Gland Plate is used only in conjunction with Vented Plinth Base Covers. The plate can be used with all ProLine subpanels or rack angles. It consists of a mounting base, three adjustable plates for cable entry, a fil
  • All hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color
Light Grey
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame Depth
800 mm
Fits Frame Width
600 mm
Material
Mild Steel
Modification Services
Yes
Mounting Type
Versatile (compatible with ProLine G2 bases, casters, levelers, or frame feet)
Product Family
ProLine
Series
ProLine G2
Size
fits 600x800mm
Size
600x800 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Filtered
Weight
13.7 lb
Package Dimensions (L x W x H)
33 IN x 25 IN x 2.75 IN
Package Dimensions (L x W x H)
83.82 cm x 63.5 cm x 6.985 cm
Package Weight (Imperial)
13.700 L
Package Weight (Metric)
6.214 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the PGPV68 PROLINE™ Enclosure

Installation guide for mounting and wiring the PGPV68 PROLINE™ enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Multimeter

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Grounding lug, Gasket material (if applicable)

  1. Select Mounting Location

    Choose a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Consider environmental factors such as temperature, humidity, and potential exposure to corrosive elements. Verify that there is adequate space for installation and future maintenance.

  2. Prepare the Enclosure

    If necessary, install any internal mounting panels, rack rails, or other accessories according to their specific instructions. Ensure all gaskets are properly seated to maintain the enclosure's environmental rating. If knockouts are present, select the appropriate size and location for cable entry and exit.

  3. Mount the Enclosure

    Using a measuring tape and level, mark the mounting hole locations on the wall or mounting surface. Drill pilot holes and install appropriate anchors if required. Securely mount the enclosure to the surface using the provided mounting hardware. Verify that the enclosure is plumb and level.

  4. Install Internal Components

    Mount any internal components such as circuit breakers, terminal blocks, or control devices within the enclosure. Follow the manufacturer's instructions for each component. Ensure proper spacing and grounding for all installed equipment.

  5. Wire the Enclosure

    Route power and signal cables through the appropriate knockouts or conduit entries. Strip wire ends to the correct length and connect them to the designated terminals using appropriate connectors. Ensure all connections are secure and properly insulated. Install a grounding conductor from the enclosure to a suitable ground point.

  6. Verify Wiring and Connections

    Before applying power, double-check all wiring connections for correctness and security. Use a multimeter to verify continuity and check for any short circuits or open circuits. Ensure that all connections match the wiring diagram.

  7. Finalize Installation

    Close and secure the enclosure door. If applicable, install any external accessories such as handles or locks. Clean the enclosure and surrounding area.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.