Authorized nVent Distributor
nVent PFS1080 - Front/Rear Plinth Base, PFS, 100x796x60mm, Brushed, Stainless Steel 304

nVent PFS1080 Front/Rear Plinth Base, PFS, 100x796x60mm, Brushed, Stainless Steel 304

UPC: 783510525941


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent PFS Plinth Base (SKU PFS1080) provides a stable, elevated foundation for floor-standing industrial enclosures. Constructed from robust AISI 304 stainless steel with 1.5 mm thick panels and 2 mm thick corners, it ensures exceptional structural integrity and corrosion resistance for demanding environments. This plinth system creates essential space beneath your enclosure, facilitating efficient cable management and simplifying installation and maintenance of electrical and data cabling. The brushed stainless steel finish offers a professional aesthetic. Each pack includes one front and one rear plinth with mounting accessories. For a fully enclosed system, pair with nVent PSS side panels. Compatible with nVent LF leveling feet (sold separately) for precise alignment on uneven surfaces. For enclosures 1600 mm wide, use two 800 mm wide plinths. The panels are 100 mm high, with double returns for added strength. The front cover is a 200 mm high panel.
  • Description: Front and rear plinth sections. For cabling without any restrictions and in accordance with the VDE 0113 standard. The plinth consists of four corner pieces with removable front covers. The side panels PSS are to be ordered separately. Produc
  • Material: AISI 304 / AISI 316L pre-grained stainless steel. Corners 2 mm and panels 1.5 mm.
  • Finish: 400 pre-grained stainless steel.
  • Pack quantity: 1x front plinth and 1x rear plinth with mounting accessories.
  • Mounting requirements: Add the side panels PSS for a complete plinth.
  • Comment: the front and rear plinth PFS, must be mounted along with side panels PSS; if creating an enclosure system with multiple enclosures then the side panels are required to be mounted at the beginning and end only
  • Mounting requirements: add the side panels PSS for a complete plinth

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Application
Controls and Drives; Factory Automation and Process Control
Color
Brushed stainless steel
Color
Unpainted
Consist of
Front/Rear Plinth, Stainless Steel;Mounting Components and Instruction Manual
Consist of
Front/Rear Plinth, Stainless Steel; Mounting Components and Instruction Manual
Construction
16 gauge
Depth
60 mm
Depth
2.36 in
Enclosure Material
Mild Steel
Finish
Brushed
Height
100 mm
Height
3.94 in
Material
AISI 304 Stainless Steel
Material
Stainless Steel 304
Mounting Type
Floor-mounted
Package Quantity
1
Product Family
Free-Standing
Series
PFS
Size
100x796x60mm
Size
3.94 x 31.34 x 2.36 inch
Thickness
51.40mm (2.024")
Thickness
1.5 mm
Thickness
16 ga
Type
Fixing
Type
IEC Enclosure Accessories
Weight
4.3 kg
Weight
9.54 lb
Weight
32 lbs./100ft
Width
31.5 in
Width
31.34 in
Width
800 mm
Works With
IEC
Package Dimensions (L x W x H)
31.87 IN x 12 IN x 8 IN
Package Dimensions (L x W x H)
80.9498 cm x 30.48 cm x 20.32 cm
Package Weight (Imperial)
9.540 L
Package Weight (Metric)
4.327 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What material is the PFS1080 plinth base made from?

The plinth base is constructed from Brushed Stainless Steel 304, with corners of 2 mm and panels of 1.5 mm thickness.

What are the dimensions of the PFS1080 plinth base?

The PFS1080 plinth base has dimensions of 3.94 inches in height, 31.5 inches in width, and 2.36 inches in depth.

What is the weight of the PFS1080 plinth base?

The PFS1080 plinth base weighs 9.54lb.

What is the purpose of the PFS1080 plinth base?

This stainless steel plinth allows for unrestricted cabling and creates extra space underneath the enclosure for easier cable installation.

What is the finish of the PFS1080 plinth base?

The PFS1080 plinth base has a 400 pre-grained brushed stainless steel finish.

What standard does the PFS1080 plinth comply with for cabling?

The plinth is designed for cabling in accordance with the VDE 0113 standard.

What are the panel thicknesses for the PFS1080 plinth?

The corners are 2 mm thick and the panels are 1.5 mm thick.

What is included in the pack for the PFS1080 plinth base?

The pack includes one front plinth, one rear plinth, and mounting accessories.

What enclosures are compatible with the PFS1080 plinth base?

For enclosures 1600 mm wide, two 800 mm wide plinths should be used.

How is the PFS1080 plinth base installed?

To complete the plinth, side panels PSS must be ordered separately and added.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.