nVent PFPC1866 - PC Frames, 1800x600x600
nVent

PFPC1866

UPC: 783510982102


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine-PC Frame (SKU: PFPC1866) is a robust, high-performance enclosure frame designed to house industrial PCs and control systems in demanding environments. Measuring 1800x600x600mm, this heavy-duty frame provides a secure, ventilated housing solution for mission-critical computing applications across manufacturing, automation, and infrastructure sectors. Engineered by nVent—a global leader in thermal management and electrical protection—the ProLine-PC series delivers unmatched durability, modularity, and compliance with industrial standards, ensuring reliable operation even in harsh conditions. Designed for versatility, the ProLine-PC Frame accommodates a wide range of PC configurations, from single-board computers to full ATX systems, making it ideal for automation controllers, HMIs, edge computing nodes, and data acquisition units. Its 1800mm height provides ample vertical space for cable management and component expansion, while the 600x600mm footprint ensures compatibility with standard rackmount and wall-mount configurations. The frame’s open design promotes natural airflow, reducing the need for active cooling in moderate environments, though optional fan kits and thermal accessories are available for high-heat applications. Industries such as oil and gas, water treatment, renewable energy, and smart manufacturing rely on ProLine-PC Frames to protect sensitive electronics from dust, moisture, vibrations, and electromagnetic interference. The frame’s powder-coated steel construction resists corrosion and wear, while its modular mounting rails allow for tool-free installation and reconfiguration. Compliance with IEC 62208 and UL 508A standards ensures the frame meets global safety and performance requirements, giving engineers confidence in its long-term reliability. Installation is streamlined thanks to the frame’s pre-drilled mounting holes and adjustable side panels, which simplify access for maintenance and upgrades. The ProLine-PC series is part of nVent’s broader ProLine ecosystem, which includes compatible doors, side panels, and cooling solutions, enabling end-to-end customization for specific environmental needs. Whether deployed in a control room, factory floor, or remote telecom site, this frame provides a scalable foundation for industrial computing infrastructure. nVent’s reputation for innovation in thermal and electrical protection solutions makes the ProLine-PC Frame a trusted choice for professionals who demand performance without compromise. With a focus on modularity, durability, and compliance, this frame is engineered to evolve alongside your application, reducing total cost of ownership while maximizing uptime. For engineers specifying industrial PC enclosures, the ProLine-PC Frame (PFPC1866) delivers the flexibility, protection, and peace of mind required in today’s connected industrial landscape.
  • Similar construction as standard ProLine frame, with 12-gauge roll formed steel and welded corner
  • Accessory front opening welded into frame to separate into compartments along the vertical; accommodates optional accessories such as the keyboard compartment (sold separately)
  • Modular mounting rails for tool-free installation
  • Natural airflow design reduces cooling requirements
  • Compliant with IEC 62208 and UL 508A standards
  • Compatible with nVent ProLine accessories for customization
  • Ideal for automation, HMI, and edge computing applications

Specifications

Application
Controls and Drives
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Finish
Powder Coating
Finish
Powder Coated
IP Rating
IP55
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Product Family
ProLine
Size
1800x600x600mm
Thickness
12 ga
Thickness
2.66 mm
Thickness
51.40mm (2.024")
Type
Internal Mounting for ProLine Industrial Enclosures
Type Number
Type 12
Weight
77 lb
Works With
NEMA
Package Dimensions (L x W x H)
30.5 IN x 30.5 IN x 75.5 IN
Package Dimensions (L x W x H)
77.47 cm x 77.47 cm x 191.77 cm
Package Weight (Imperial)
77.000 L
Package Weight (Metric)
34.927 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PFPC1866 Controller

This guide provides step-by-step instructions for installing and configuring the PFPC1866 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PFPC1866 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the ends of the wires. Connect the power and signal wires to the appropriate terminals on the PFPC1866 controller, ensuring a secure connection.

  3. Verify connections

    Utilize a multimeter to check the voltage at the terminals to ensure proper power supply. Confirm that all connections are secure and correctly wired.

  4. Configure the controller

    Access the configuration settings of the PFPC1866 controller through the designated interface. Input the necessary parameters as per your application requirements.

  5. Calibrate the system

    Follow the calibration procedure outlined in the user manual to ensure the PFPC1866 controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.