Authorized nVent Distributor
nVent PFAL1126 - Plinth, 100x1200x600, Aluminium, RAL7035

nVent PFAL1126 Plinth, 100x1200x600, Aluminium, RAL7035

UPC: 783510525835


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent PFAL1126 is an aluminum plinth for floor-standing enclosures. Manufactured by nVent, it measures 100mm (H) x 1200mm (W) x 600mm (D). Constructed from 3mm aluminum profiles and 2mm panels with AlMg3 material, it features a durable RAL 7035 polyester powder coating. Designed for cable management, it includes removable front and rear plates for unrestricted access. Ideal for industrial environments requiring organized cabling and robust support.
  • Description: Aluminium plinth allows cabling without any restrictions. The plinth consists of two lateral profiles with removable front and rear plates.
  • Material: Aluminium AlMg3. Profiles: 3 mm and panels 2 mm.
  • Finish: RAL 7035 polyester powder coated.
  • Pack quantity: 1 plinth with mounting material.
  • Compatible with nVent floor-standing enclosures

Specifications

Color
Light Gray
Color
RAL7035
Color
Gray
Color Code
RAL 7035
Depth
23.62 in
Depth
600 mm
Enclosure Material
Aluminum
Height
3.94 in
Height
44 IN
Material
aluminium
Material
Aluminum
Product Family
Free-Standing
Size
100x1200x600
Type
Fixing
Width
1,200 mm
Width
47.24 in
Works With
IEC
Package Dimensions (L x W x H)
47.62 IN x 4.31 IN x 47.87 IN
Package Dimensions (L x W x H)
120.9548 cm x 10.9474 cm x 121.5898 cm
Package Weight (Imperial)
17.000 L
Package Weight (Metric)
7.711 kg
Plinth, 100x800x600, Aluminium, RAL7035

PFAL1086

Plinth, 100x800x600, Aluminium, RAL7035
IME VENTED PAGODA TOP 600X800

IPT68

IME VENTED PAGODA TOP 600X800
C ALUMINUM PROFIL 29X19 ADAPTED FOR CADRYS DELTA WIDTH 600

51106032

C ALUMINUM PROFIL 29X19 ADAPTED FOR CADRYS DELTA WIDTH 600
Universal raintight hubs are rated for outdoor enclosures and come in a variety of sizes for every ABB load center or panel. The TC150 has a diameter of 1.50" and has a base size of 3".

TC150

Universal raintight hubs are rated for outdoor enclosures and come in a variety of sizes for every ABB load center or panel. The TC150 has a diameter of 1.50" and has a base size of 3".
PVC Coated F Service Head, Threaded Rigid, Conduit Size 1 Inch, Number and Diameter of Knockouts Two at 7/16 Inch, Three at 1/2 Inch, Aluminum,Gray

F385-G

PVC Coated F Service Head, Threaded Rigid, Conduit Size 1 Inch, Number and Diameter of Knockouts Two at 7/16 Inch, Three at 1/2 Inch, Aluminum,Gray
8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8064HLL

8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet
Pole Mount Kit for 24 x 24 enclosure

APMK24

Pole Mount Kit for 24 x 24 enclosure
Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

SBL300

Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack
DS200 ANGLE ADAPTER METAL GRAY | Size 6 TYPE 3R

39-2A027

DS200 ANGLE ADAPTER METAL GRAY | Size 6 TYPE 3R

Frequently Asked Questions

What are the dimensions of the PFAL1126 plinth?

The plinth has a height of 3.94 inches, a width of 47.24 inches, and a depth of 23.62 inches.

What material is the PFAL1126 plinth made of?

The plinth is constructed from Aluminium AlMg3, with profiles of 3 mm and panels of 2 mm.

What is the color and finish of the plinth?

The plinth is finished in RAL 7035 polyester powder coating, which is a light gray color.

How does this plinth facilitate cabling?

The plinth allows for unrestricted cabling by creating extra space underneath the enclosure.

What is included with the plinth pack?

Each pack contains one plinth along with the necessary mounting material.

How to Demount the Front PFAL Plinth

Detailed instructions for safely demounting the front plinth of a PFAL unit while an EKOM module is installed, including required tools and torque specifications.

Estimated time: 15m

Tools needed:

SW8 Wrench, T30 Torx Bit, Torque Wrench

  1. Gather Tools and Prepare

    Collect the necessary tools: an SW8 wrench, a T30 Torx bit, and a torque wrench. Ensure the PFAL unit is powered off and disconnected from any power source before proceeding to ensure safety.

  2. Remove Main Plinth Fasteners (A and C)

    Using the SW8 wrench and T30 Torx bit, carefully loosen and remove the four M10x25 bolts (A) and their corresponding M10 fasteners (C) that secure the main part of the front plinth. These fasteners have a specified torque of 10-15 Nm for reinstallation.

  3. Remove Secondary Plinth Fasteners (B)

    Next, locate and remove the two M6x16 bolts (B) that secure any secondary attachment points of the front plinth. These fasteners have a specified torque of 8-10 Nm for reinstallation.

  4. Detach Front Plinth

    Once all fasteners (A, B, and C) are completely removed, carefully detach and remove the front PFAL plinth from the unit. Store all removed fasteners in a safe place for future reinstallation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.