nVent PF2050 - Front/Rear Plinths, PF, 200x498x63mm, Umbra Gray, Zinc Plated, Mild Steel

nVent PF2050 Front/Rear Plinths, PF, 200x498x63mm, Umbra Gray, Zinc Plated, Mild Steel

UPC: 783510525712


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent PF2050 Front/Rear Plinth (SKU: PF2050) is a 200 mm high, 498 mm wide, and 63 mm deep mild steel plinth designed to elevate floor-standing electrical enclosures. The plinth features a RAL 7022 structured powder-coated Umbra Gray finish for superior corrosion resistance. It includes removable front and rear covers, with the rear cover consisting of two 100 mm high panels for 200 mm high plinths. All panels incorporate double returns for added strength. The PF2050 is compatible with nVent PS side panels and PCP transversal profiles, enhancing rigidity and supporting cable ducts in combined enclosure configurations.
  • Description: Front and rear plinth sections. For cabling without any restrictions and in accordance with the VDE 0113 standard. The plinth consists of four corner pieces with removable front covers. The side panels PS are to be ordered separately. Produce
  • Material: Corner pieces in 2 mm and panels in 1.5 mm mild steel.
  • Finish: RAL 7022 structured powder coating.
  • Pack quantity: 1 set of 4 corner pieces including covers. Front and rear panel (2 rear panels for 200 mm high plinths) with mounting accessories. Mounting accessories for side panels PS or transversal profiles PCP.
  • Mounting requirements: Add the side panels PS for a complete plinth. When combining enclosures it is recommended to add transversal panels PCP for cable duct support and extra rigidity.
  • Benefit: the plinth allows enclosures to be fixed to the floor without the need for interior access
  • Comment: the front and rear plinth PF, must be mounted along with side panels PS; if creating an enclosure system with multiple enclosures, the side panels are required to be mounted at the beginning and end only
  • Comment: to reinforce the combined plinths, plinth combining profiles PCP/PCPK, should be used
  • Mounting requirements: add the side panels PS for a complete plinth; when combining enclosures, it is recommended to add transversal panels PCP for cable duct support and extra rigidity

Specifications

Application
Factory Automation and Process Control; Controls and Drives; Power Distribution
Application
Controls and Drives;Factory Automation and Process Control;Power Distribution
Application
Factory Automation and Process Control; Controls and Drives
Color
RAL 7022 Umbra Gray
Color
Gray
Color
Grey
Color
Umbra Gray
Color Code
RAL 7022
Consist of
Front/Rear Plinths;Mounting Components and Instruction Manual
Consist of
Front/Rear Plinths; Mounting Components and Instruction Manual
Construction
16 gauge
Depth
63 mm
Depth
2.46 in
Enclosure Material
Mild Steel
Finish
Powder Coated
Finish
Powder Coating
Height
200 mm
Height
7.87 in
Material
Mild Steel
Mounting Type
Mounted to floor for elevation
Package Quantity
1
Product Family
Free-Standing
Series
PF
Size
7.87 x 19.61 x 2.46 inch
Size
200x498x63mm
Thickness
51.40mm (2.024")
Thickness
16 ga
Thickness
1.5 mm
Type
IEC Enclosure Accessories
Type
Fixing
Weight
13.7 lb
Weight
6.2 kg
Weight
32 lbs./100ft
Width
19.69 in
Width
19.61 in
Width
500 mm
Works With
IEC
Package Dimensions (L x W x H)
20.06 IN x 8.25 IN x 20.31 IN
Package Dimensions (L x W x H)
50.9524 cm x 20.955 cm x 51.5874 cm
Package Weight (Imperial)
13.700 L
Package Weight (Metric)
6.214 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the dimensions of the PF2050 plinth?

The PF2050 plinth has dimensions of 7.87 inches in height, 19.69 inches in width, and 2.46 inches in depth.

What material is the PF2050 plinth made from?

The plinth is constructed from mild steel, with corner pieces of 2 mm thickness and panels of 1.5 mm thickness.

What is the finish and color of the PF2050 plinth?

The plinth has a RAL 7022 structured powder coating in Umbra Gray.

What is the purpose of the PF2050 plinth?

The plinth allows for cabling without restrictions and creates extra space underneath the enclosure, in accordance with the VDE 0113 standard.

What components are included in a PF2050 plinth package?

A package includes four corner pieces with removable covers and mounting accessories for side panels or transversal profiles.

Are side panels included with the PF2050 plinth?

No, the side panels (PS) must be ordered separately to complete the plinth.

How are cables managed with the 200 mm high plinth?

The 200 mm high plinth includes a rear cover for cabling, consisting of two removable 100 mm high panels.

What is the recommended use when combining enclosures with plinths?

When combining enclosures, it is recommended to add transversal panels (PCP) for cable duct support and extra rigidity.

What is the weight of the PF2050 plinth?

The PF2050 plinth weighs 13.7 lb.

What is the thickness of the plinth panels?

The panels of the plinth are 1.5 mm thick, and the corner pieces are 2 mm thick.

How to Fasten PF/PV/PS Series Components

This guide outlines the fastening procedures for various components within the PF/PV/PS series, detailing bolt types, required tools, and torque specifications for secure assembly.

Estimated time: 30m

Tools needed:

Wrench (SW19), Wrench (SW8), Torx wrench (T40), Torque wrench

Supplies needed:

M12 bolts, M12x20 bolts, M8x16 bolts

  1. Fasten Component A

    Using an SW19 wrench and a torque wrench, secure Component A with M12 bolts. Apply a torque of 15-20 Nm to ensure proper fastening.

  2. Fasten Component B

    Using an SW8 wrench and a torque wrench, secure Component B with M8x16 bolts. Apply a torque of 10-15 Nm for secure attachment.

  3. Fasten Component C

    Using an SW19 wrench and a torque wrench, secure Component C with M12 bolts. Apply a torque of 15-20 Nm, similar to Component A.

  4. Fasten Component D

    Using a T40 Torx wrench and a torque wrench, secure Component D with M12x20 bolts. Apply a torque of 15-20 Nm.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.