Overview
- Side hinged doors with 130-degree swing
- Seamless foam in place gasket
- Hidden side hinges with 130-degree door swing (optional 180-degree kit available)
- Two-point latching system with flush slotted quarter-turn insert
- Seamless foam-in-place gasket for IP66/NEMA 4X watertight and dust-tight seal
Specifications
Application | Controls and Drives; Corrosive Environments |
Color | Light Gray |
Color | LtGray |
Color Code | RAL 7035 |
Depth | 565 mm |
Depth | 22.23 |
Depth | 565 |
Door Size | 19.91 x 23.30 in |
Door Size | 506 x 592 mm |
Finish | Powder Coated |
Height | 500 mm |
Height | 19.69 |
Height | 500 |
Ip Rating | IP66/IP67 |
Material | Mild Steel |
Material | Steel |
Modification Services | Yes |
Mounting Type | Side-hinged with hidden hinges |
Mounting Type | Side-hinged with 130-degree swing |
Nema Rating | NEMA 4X |
Product Family | ProLine |
Series | ProLine |
Size | fits 507x600mm |
Size | 507x600mm |
Thickness | 16 ga |
Thickness | 1.52 mm |
Type | Other Accessories |
Type | HMI Enclosure Systems |
Weight | 12 lb |
Width | 600 mm |
Width | 23.62 in |
Works With | NEMA |
Package Dimensions (L x W x H) | 26 IN x 23.5 IN x 3 IN |
Package Dimensions (L x W x H) | 66.04 cm x 59.69 cm x 7.62 cm |
Package Weight (Imperial) | 12.000 L |
Package Weight (Metric) | 5.443 kg |
How to Install the PDS56R Controller
This guide provides step-by-step instructions for installing and configuring the PDS56R Controller, including wiring and calibration.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter, Drill
Supplies needed:
Mounting screws, Self-tapping screws, Terminal connectors
- Mount the controller
Secure the PDS56R Controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the wires and connect them to the appropriate terminals on the PDS56R Controller. Ensure all connections are secure and insulated.
- Verify connections
Utilize a multimeter to check the voltage and continuity of the connections made. Ensure that all readings are within the specified range to confirm proper installation.
- Configure the controller
Follow the manufacturer's guidelines to program the PDS56R Controller settings according to your specific application requirements.
- Calibrate the system
Perform calibration procedures as outlined in the user manual to ensure the controller operates accurately within the desired parameters.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.