nVent PDS46R - Doors for Rear ProLine Sloped Tops, fits 407x600mm, Lt Gray, Steel
nVent

PDS46R

UPC: 783510368494


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine Upper Rear Door (SKU: PDS46R) is constructed from 16-gauge steel with a RAL 7035 textured light-gray polyester powder paint finish. Designed for ProLine Sloped Tops, this rear door measures 405x592mm (15.96x23.30 inches) and weighs 10.0 lbs. It features side-hinged mounting with hidden hinges providing a 130-degree door swing, with an optional 180-degree hinge kit available. The door can be hinged from either the left or right side. Security is provided by a two-point latching system utilizing a flush slotted quarter-turn insert, compatible with standard ProLine handle and insert options. For operator interface support, it integrates with ProLine Frame Shelves or ProLine Grid Straps. A seamless foam-in-place gasket ensures a watertight and dust-tight seal, providing IP66 or NEMA 4X protection. A ground stud and all necessary mounting hardware are included for straightforward installation. This rear door is ideal for protecting sensitive equipment in industrial control and automation applications.
  • Side hinged doors with 130-degree swing
  • Seamless foam in place gasket
  • Features a 130-degree side-hinged door swing with optional 180-degree kit.
  • Provides secure two-point latching with a flush slotted quarter-turn insert.
  • Offers IP66/NEMA 4X rated protection with a seamless foam-in-place gasket.

Specifications

Application
Controls and Drives
Color
Light Gray
Color
LtGray
Color Code
RAL 7035
Depth
22.23
Depth
565
Depth
565 mm
Door Size
15.96 x 23.30 in
Door Size
405 x 592 mm
Finish
Powder Coated
Height
400 mm
Height
15.75
Height
400
Ip Rating
IP66/IP67
IP Rating
IP66
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
Side-hinged with 130-degree swing
Mounting Type
Side-hinged with hidden hinges
Nema Rating
NEMA 4X
Product Family
ProLine
Series
ProLine
Size
fits 407x600mm
Size
407x600mm
Thickness
1.52 mm
Thickness
16 ga
Type
HMI Enclosure Systems
Type
Other Accessories
Weight
10 lb
Width
23.62 in
Width
600 mm
Works With
NEMA
Package Dimensions (L x W x H)
25 IN x 17 IN x 3 IN
Package Dimensions (L x W x H)
63.5 cm x 43.18 cm x 7.62 cm
Package Weight (Imperial)
10.000 L
Package Weight (Metric)
4.536 kg
Doors for Rear ProLine Sloped Tops, fits 507x600mm, Lt Gray, Steel

PDS56R

Doors for Rear ProLine Sloped Tops, fits 507x600mm, Lt Gray, Steel
Multi-Way Switchgear, Single-Sided PAdmount. 27kV/12.5kA, 2-Ways, 1-Source Way - 3-Phase MVI Fault Interrupter - 600 Amp Bushing Interface - Internal Control. 1-Load Way - No Components - No Interface - No Control. No PT to Power Control. No Cam-Op and Integral Position Indicator. Enclosure- Mild Steel, Munsell Green 7GY 3.29/1.5 and Flat Ground Bar (Standard), English Labels and Instructions.

MP3221P1X6XIXXXAE000

Multi-Way Switchgear, Single-Sided PAdmount. 27kV/12.5kA, 2-Ways, 1-Source Way - 3-Phase MVI Fault Interrupter - 600 Amp Bushing Interface - Internal Control. 1-Load Way - No Components - No Interface - No Control. No PT to Power Control. No Cam-Op and Integral Position Indicator. Enclosure- Mild Steel, Munsell Green 7GY 3.29/1.5 and Flat Ground Bar (Standard), English Labels and Instructions.
HMI CABLE KIT CFW900-CCHMIR03M

CFW900-CCHMIR03M

HMI CABLE KIT CFW900-CCHMIR03M
3P CONT S 24V 50/60Hz 2NO2NC

CC75SA24

3P CONT S 24V 50/60Hz 2NO2NC

How to Install the PDS46R Controller

This guide provides step-by-step instructions for installing and configuring the PDS46R Controller, ensuring proper setup and calibration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Drill

Supplies needed:

Mounting screws, Terminal connectors, Self-tapping screws

  1. Mount the controller

    Secure the PDS46R controller to the designated mounting location using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the appropriate terminals on the PDS46R controller. Ensure all connections are tight and secure.

  3. Verify the connections

    Utilize a multimeter to check the voltage and continuity of the connections. Ensure that all readings are within the specified range to avoid damage to the controller.

  4. Program the controller

    Follow the programming instructions specific to the PDS46R to configure the settings according to your application requirements.

  5. Calibrate the controller

    Perform the calibration procedure as outlined in the user manual to ensure accurate readings and functionality of the PDS46R controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.