Contact for Pricing
Overview
- Drastically reduces data center energy costs
- Reduces data center carbon footprint
- Quick and simple installation
- Custom built to facility specifications
- Channels hot air from hot aisle to a facility ceiling plenum
- Separates hot from cold air, preventing intermixing
- Comes in 600mm, 750mm, 800mm and 1200mm widths
- Built to match cabinet and facility ceiling height
- Clean and aesthetic design
- Panels can be field modified for cable entry
Specifications
Application | Datacom and Telecom Equipment;Networking, Storage and Data Center;Telecom and Data Protection |
Color | Black |
Color | Black;Ral 9011 Black |
Color | Graphite Black |
Color Code | RAL 9011 |
Consist Of | Plenum Side Panel, 700mm |
Construction | Transparent Polycarbonate |
Depth | 2.95 in |
Depth | 75 mm |
Finish | Transparent |
Height | 44 IN |
Height | 58.25 in |
Insulation | No |
Knockouts | No |
Knockouts | False |
Material | Polycarbonate |
Product Family | ProLine Containment System |
Series | Hot Aisle Return Plenum |
Size | 58.25 x 29.48 x 2.95 inch |
Size | 1480x700x75 mm |
Type | Aisle Containment |
Weight | 19.8 lb |
Width | 750 mm |
Width | 29.48 in |

QIPE15
Panel Extenders 15mm (4), Bulletin Q41Y (QLINE® Type 4X Encl. Panels and Accessories - I Series Accessories), Size/Dims: fits QLINE IHow to Install the PCPPS750 Controller
Complete installation guide for mounting and wiring the PCPPS750 Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the PCPPS750 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect power supply
Using terminal connectors, connect the power supply wires to the designated terminals on the PCPPS750. Verify that the connections are secure and insulated.
- Configure initial settings
Power on the PCPPS750 and use the interface to navigate to the configuration menu. Set the required parameters according to your application needs.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure accurate performance. Use a multimeter to verify output signals during calibration.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.