nVent PCE208300 - Cable Entry Cabinets, fits 2000x800mm, Lt Gray, Steel
nVent

PCE208300

UPC: 783510342692


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent PCE208300 Cable Entry Cabinet is engineered to provide a robust and efficient solution for managing cable ingress into industrial enclosures, particularly those with side-mounted configurations. Designed to fit enclosures measuring 2000x800mm, this cabinet ensures seamless integration and superior cable management. Its light gray, durable steel construction offers excellent protection against environmental factors and mechanical stress, making it suitable for demanding industrial applications. Facilitating straightforward cable entry into the sides of enclosures, the PCE208300 features an open top and bottom design. This configuration allows for easy cable access and provides ample space for effective cable routing and organization. To maintain the integrity of the enclosure's environment, optional closure plates are available. These plates effectively seal the open ends of the cabinet, preventing the ingress of dust, moisture, and other contaminants, thereby safeguarding sensitive electrical and electronic components within. The front opening of the nVent Cable Entry Cabinet offers versatile closure options to meet specific operational and security requirements. Users can choose between a hinged solid door for frequent access or a screw-on solid cover for a more permanent and secure seal. Both options are designed for ease of installation and reliable performance. Furthermore, the cabinet is equipped with a foam-in-place gasket, a critical component for ensuring a tight seal and maintaining the enclosure's environmental protection rating. This gasket, combined with optional accessories, guarantees that the enclosure's internal environment remains protected, crucial for the longevity and reliability of housed equipment. Manufactured by nVent, a trusted leader in electrical enclosure solutions, the PCE208300 benefits from decades of expertise in designing and producing high-quality industrial products. The commitment to robust engineering and material selection ensures that this cable entry cabinet meets stringent industry standards. Its application spans various sectors, including manufacturing, automation, power distribution, telecommunications, and data centers, where reliable cable management and environmental protection are paramount. Professionals rely on nVent products for their durability, ease of installation, and ability to maintain enclosure integrity in challenging conditions. The PCE208300 is an essential component for any facility prioritizing organized, secure, and environmentally protected cable entry solutions.
  • 14 gauge (1.75mm) mild steel
  • RAL 7035 textured light-gray polyester powder paint finish
  • Foam-in-place gasket and optional accessories to maintain environmental integrity
  • Open top and bottom of cabinet; closure plates sold separately
  • Front opening of cabinet can be closed with either solid door or cover

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
11.78
Depth
299
Finish
Powder Coated
Fits Frame
2000 tall x 800 deep mm
Height
78.74
Height
2,000
Material
Mild Steel
Material
Steel
Modification Services
Yes
Product Family
ProLine
Size
2000x800mm
Size
fits 2000x800mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Enclosures
Weight
106 lb
Width
31.5
Width
800
Package Dimensions (L x W x H)
79.5 IN x 34 IN x 13.5 IN
Package Dimensions (L x W x H)
201.93 cm x 86.36 cm x 34.29 cm
Package Weight (Imperial)
106.000 L
Package Weight (Metric)
48.082 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PCE208300 Controller

This guide provides step-by-step instructions for installing and configuring the PCE208300 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PCE208300 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the terminal connectors on the controller. Ensure all connections are tight and secure to prevent any electrical faults.

  3. Power on and configure

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are correct. Follow the manufacturer's instructions to complete the initial configuration settings.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.