Authorized nVent Distributor
nVent P2TD166 - ProLine G2 Disconnect Solid Tops, fits 1600x600mm, Painted

nVent P2TD166 ProLine G2 Disconnect Solid Tops, fits 1600x600mm, Painted

UPC: 783510329976


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Disconnect Solid Top (SKU: P2TD166)** is a precision-engineered component designed to deliver robust structural integrity and seamless integration for industrial disconnect enclosures exceeding 1000mm in width. Manufactured by nVent—a global leader in electrical and thermal management solutions—the ProLine G2 Solid Top is engineered to pair with ProLine G2 Disconnect Frames and Doors, enabling the configuration of fully customized disconnect enclosure solutions tailored to high-performance industrial environments. This solid top variant, sized at 1600x600mm and painted for durability, is specifically optimized for applications requiring enhanced stability and space efficiency, particularly where hinged mullions are utilized to facilitate access and maintenance. The ProLine G2 Disconnect Solid Top is distinguished by its **offset center support**, which is intentionally shifted 100mm to accommodate hinged mullion configurations without compromising structural integrity. This design innovation ensures compatibility with ProLine G2’s modular framework while maintaining the same high-quality construction as standard ProLine G2 components, including gland plates and mounting subpanels. The result is a cohesive, high-strength enclosure system capable of withstanding harsh industrial conditions, including vibration, thermal cycling, and mechanical stress. This product is ideal for a wide range of industrial applications, including **power distribution centers, motor control rooms, renewable energy installations, and manufacturing facilities** where reliable electrical isolation and protection are critical. The solid top design provides a secure mounting surface for internal components while preventing debris ingress and enhancing thermal management. Professionals in electrical engineering, panel building, and facility maintenance rely on ProLine G2 components for their **modularity, durability, and compliance with industry standards**, ensuring long-term performance and reduced downtime. nVent’s ProLine G2 Disconnect Solid Top is part of a comprehensive ecosystem of enclosure solutions, offering engineers and contractors the flexibility to design enclosures that meet specific dimensional and functional requirements. The painted finish not only improves corrosion resistance but also simplifies integration with existing infrastructure, reducing installation time and labor costs. With a **U.S.-manufactured** pedigree and adherence to stringent quality controls, this component reflects nVent’s commitment to innovation and reliability in electrical protection systems. For industries prioritizing **safety, efficiency, and scalability**, the ProLine G2 Disconnect Solid Top (P2TD166) stands as a trusted choice. Its compatibility with ProLine G2’s modular architecture ensures seamless upgrades and expansions, while its robust construction supports compliance with NEC, UL, and IEC standards. Whether deployed in a new construction project or as part of a retrofit, this solid top delivers the performance and versatility required to meet the demands of modern industrial electrical systems.
  • Solid Tops are finished with paint over plated surfaces
  • Solid Tops are gasketed and include ground studs
  • Bolts are included to hold the top in place (lifting eyes can be used instead of bolts)
  • Compatible with ProLine G2 Solid Tops, Gland Plates, and Mounting Subpanels
  • U.S.-manufactured for reliability and compliance with industry standards

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1600 x 600 mm
Material
Mild Steel
Product Family
ProLine
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
545 lb
Package Dimensions (L x W x H)
67 IN x 27 IN x 2.5 IN
Package Dimensions (L x W x H)
170.18 cm x 68.58 cm x 6.35 cm
Package Weight (Imperial)
30.000 L
Package Weight (Metric)
13.608 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2TD166 PROLINE G2 Enclosure

Installation guide for mounting and wiring the P2TD166 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Multimeter

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Grounding lug, Grounding wire

  1. Prepare the Mounting Location

    Select a suitable location for the enclosure. Ensure the mounting surface is level and capable of supporting the weight of the enclosure and its contents. Use a measuring tape to mark the desired mounting points.

  2. Mount the Enclosure

    Drill pilot holes at the marked locations. Secure the P2TD166 enclosure to the mounting surface using appropriate mounting hardware. Verify that the enclosure is securely fastened and level.

  3. Install Internal Components (if applicable)

    If mounting internal components such as backplates or subpanels, follow their specific installation instructions. Ensure all components are securely fastened within the enclosure.

  4. Ground the Enclosure

    Connect a grounding wire from the enclosure's grounding point to a suitable earth ground. Use a grounding lug and appropriate wire connectors. Verify the integrity of the ground connection with a multimeter.

  5. Wire Internal Devices

    Route and connect wiring for any internal devices according to their respective diagrams and local electrical codes. Use wire strippers and crimpers as needed. Ensure all connections are secure and properly insulated.

  6. Final Inspection

    Perform a thorough inspection of all wiring and mounting. Ensure all covers and doors are properly secured. Verify that no tools or debris are left inside the enclosure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.