nVent P2T104 - ProLine G2 Solid Top, fits 1000x400mm, Painted
nVent

P2T104

UPC: 783510326326


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Solid Top (SKU: P2T104) is a painted steel enclosure component designed to seal the top opening of 1000x400mm nVent ProLine G2 frames. Constructed from 16-gauge (1.5 mm) steel with a RAL 7035 textured light gray polyester powder paint finish, it provides robust protection against environmental contaminants. A seamless polyurethane gasket ensures a watertight and dust-tight seal. Installation is facilitated by four M12 hex bolts. This component is suitable for industrial automation, telecommunications, data centers, and power distribution applications where equipment protection is critical.
  • Lifting eyes can be used to attach the solid top, in place of the included hardware
  • Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
  • Additional support provisions need to be made to support top mount air conditioners or other top mount accessories
  • Includes four M12 hex bolts for installation
  • Solid Tops are finished with paint over plated surfaces

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color
Painted
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1000x400 mm
Ip Rating
IP66/IP67
Material
Mild Steel
Material
Steel
Mounting Type
M12 hex bolts
Product Family
ProLine
Series
ProLine G2
Size
1000x400mm
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
14 lb
Package Dimensions (L x W x H)
42.25 IN x 18.5 IN x 2 IN
Package Dimensions (L x W x H)
107.315 cm x 46.99 cm x 5.08 cm
Package Weight (Imperial)
14.000 L
Package Weight (Metric)
6.350 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2K1846 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1846 Controller, ensuring proper setup and functionality.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1846 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Verify the connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements and save the settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual. Use a multimeter to verify output signals and adjust settings as necessary for accurate performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.