nVent P2RA19S6 - ProLine G2 19-Inch Rack Angles, Sq Hole, 600mm, Conductive, Steel

nVent P2RA19S6 ProLine G2 19-Inch Rack Angles, Sq Hole, 600mm, Conductive, Steel

UPC: 783510326159


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 19-Inch Rack Angles (SKU: P2RA19S6) represent a significant advancement in industrial enclosure mounting solutions. Designed for robust performance and ease of installation, these conductive steel rack angles are engineered to seamlessly integrate with the ProLine G2 frame system. Unlike traditional methods that rely on cumbersome cage nut and screw combinations, the ProLine G2 Rack Angles utilize advanced BV-M6 fasteners. This innovative approach streamlines the mounting process, reducing assembly time and potential for errors, which is critical in fast-paced industrial environments. The height and rack unit (RU) count of these rack angles are meticulously optimized to complement the specific frame heights within the ProLine G2 enclosure series. This ensures a precise fit and maximizes usable space within the enclosure, allowing for efficient layout of critical equipment. Each rack angle features two distinct mounting surfaces, providing versatile attachment points for a wide array of rack-mount equipment and accessories. This dual-surface design enhances flexibility, accommodating various installation configurations and future expansion needs. Adherence to industry standards is paramount in industrial infrastructure. The nVent ProLine G2 Rack Angles proudly comply with AN SI/EIA RS-310-D rack mounting standards. This compliance guarantees interoperability with a vast range of standard rack-mountable equipment, ensuring that your chosen components will fit and function as intended. The conductive steel construction not only provides exceptional mechanical strength and durability but also contributes to the overall electrical grounding and integrity of the enclosure system, a vital consideration for sensitive electronic equipment. Key benefits of the nVent ProLine G2 Rack Angles include: * **Simplified Installation:** BV-M6 fastener system eliminates the need for separate cage nuts and screws. * **Optimized Fit:** Designed to perfectly match ProLine G2 frame heights and RU requirements. * **Versatile Mounting:** Two mounting surfaces accommodate diverse equipment and accessory installations. * **Industry Compliance:** Meets AN SI/EIA RS-310-D standards for broad compatibility. * **Durable Construction:** Conductive steel ensures long-lasting structural integrity and electrical grounding. These rack angles are an essential component for any professional seeking to build or upgrade industrial control panels, server racks, telecommunications equipment cabinets, or any application requiring secure and standardized equipment mounting. nVent's reputation for quality and innovation in enclosure solutions makes the ProLine G2 Rack Angles a trusted choice for demanding environments where reliability and performance are non-negotiable. The US-manufactured origin further underscores a commitment to quality manufacturing and supply chain reliability. Whether you are deploying new systems or retrofitting existing infrastructure, these rack angles offer a superior mounting solution.
  • Furnished in pairs
  • Can be mounted directly to the frame, or at variable depths using Adjustable Rack-Mounting Rails or Grid Straps; when mounted to the frame there is 44mm between the door opening and the Rack Angle mounting surface
  • Single-bay Frames: in a 600-mm wide frame, Rack Angles can be mounted in-line with the frame; in an 800-mm wide frame, Adjustable Rack-Mounting Rails or Frame Reducing Brackets are required (sold separately) to achieve the 19-inch rack spacing
  • Double-Bay Frames: in a 1200-mm wide frame, Center Uprights must be used to create a mounting surface in the center of the enclosure for either bay; in a 1600-mm frame, Center Uprights are again required in addition to Frame Reducing Brackets or Adjustabl
  • Tapped-Hole Rack Angles accommodate 10-32 screws for equipment mounting
  • Square-Hole Rack Angles accept both metric and English cage nuts and screws: most commonly M5, M6, and 10-32 screws
  • Optional Shelves, Drawers, and Guides require two sets of Rack Angles to secure within the frame
  • All mounting hardware for Rack Angle installation into the frame is included; mounting hardware for securing rack-mount equipment/accessories to the Rack Angles is either supplied with the item or purchased separately
  • Tapped Rack Angles are constructed from 12 gauge (2.5 mm) conductive steel, while Square-Hole Rack Angles are from 14 gauge (1.75 mm) conductive steel
  • Load rating of 20 lbs (9.1 kg) per rack unit for equipment under 20-inches (508 mm) in depth; All equipment over 20-inches in depth requires rear rack angles for support

Specifications

Application
Controls and Drives
Color
Unpainted
Depth
1.89
Depth
48
Finish
Plated
Fits Frame Height
600 mm
Height
20
Height
509
Hole Type
Square
Material
Mild Steel
Material
Steel
Mounting Type
Square Hole
Product Family
ProLine
Rack Units
11
Series
ProLine G2
Size
600mm
Thickness
1.9 mm
Thickness
14 ga
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
4.9 lb
Width
2.56
Width
65
Package Dimensions (L x W x H)
28.4 IN x 5.5 IN x 4.75 IN
Package Dimensions (L x W x H)
72.136 cm x 13.97 cm x 12.065 cm
Package Weight (Imperial)
4.900 L
Package Weight (Metric)
2.223 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2RA19S6 Controller

This guide provides step-by-step instructions for installing and configuring the P2RA19S6 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2RA19S6 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure and correctly oriented.

  3. Configure the controller settings

    Power on the controller and use the programming interface to set the desired operational parameters. Follow the on-screen prompts to complete the configuration.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the user manual. Ensure all readings are within acceptable ranges.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.