nVent P2RA19S20 - ProLine G2 19-Inch Rack Angle Sq Hole, 2000mm, Conductive, Steel
nVent

P2RA19S20

UPC: 783510326135


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 19-Inch Rack Angle (SKU: P2RA19S20) is a high-performance, conductive steel mounting solution designed for professional rack infrastructure systems. Engineered to meet ANSI/EIA RS-310-D rack mounting standards, this rack angle provides a robust and reliable foundation for securing rack-mount equipment and accessories in data centers, telecommunications facilities, industrial control rooms, and enterprise server environments. The ProLine G2 Rack Angle features a 19-inch width with square holes, optimized for compatibility with ProLine G2 frame heights and BV-M6 fasteners, eliminating the need for traditional cage nuts and screws. This streamlined mounting approach reduces installation time, minimizes hardware complexity, and enhances structural integrity, making it an ideal choice for mission-critical applications where reliability and efficiency are paramount. Designed for versatility, the ProLine G2 Rack Angle offers two distinct mounting surfaces, allowing for flexible attachment of servers, switches, patch panels, and other rack-mounted devices. The conductive steel construction ensures proper grounding and electromagnetic interference (EMI) shielding, which is essential for maintaining signal integrity in high-density networking and computing environments. The 2000mm length provides ample coverage for standard rack heights, while the square hole pattern accommodates a wide range of mounting configurations, including adjustable rails and accessories. This adaptability makes the ProLine G2 Rack Angle suitable for both new installations and retrofitting existing rack systems. Professionals in data center operations, IT infrastructure, and industrial automation rely on nVent’s ProLine G2 series for its precision engineering and durability. The ProLine G2 Rack Angle is part of nVent’s comprehensive line of rack infrastructure solutions, which are trusted by Fortune 500 companies, government agencies, and telecom providers worldwide. Whether deployed in hyperscale data centers, edge computing facilities, or industrial automation hubs, this rack angle delivers consistent performance under demanding conditions. Its corrosion-resistant finish and high-load-bearing capacity ensure long-term reliability, reducing maintenance costs and downtime. Installation is straightforward, thanks to the optimized height and rack unit count alignment with ProLine G2 frames. The BV-M6 fastener system simplifies assembly, reducing the risk of misalignment or loose connections that can compromise equipment stability. For technicians and engineers, this means faster deployments, fewer errors, and greater confidence in the structural integrity of the rack system. Additionally, the conductive properties of the steel help maintain a secure ground path, which is critical for protecting sensitive electronics from electrostatic discharge (ESD) and ensuring compliance with industry standards. nVent, a global leader in electrical and thermal management solutions, brings decades of expertise to the ProLine G2 Rack Angle. The company’s commitment to innovation and quality is reflected in products that meet rigorous industry certifications, including UL, CE, and RoHS compliance. By choosing the ProLine G2 Rack Angle, professionals gain a trusted component that enhances the performance, scalability, and longevity of their rack infrastructure systems. Whether upgrading an existing setup or designing a new facility, this rack angle provides the strength, flexibility, and reliability required for today’s demanding IT and industrial applications.
  • Furnished in pairs
  • Can be mounted directly to the frame, or at variable depths using Adjustable Rack-Mounting Rails or Grid Straps; when mounted to the frame there is 44mm between the door opening and the Rack Angle mounting surface
  • Single-bay Frames: in a 600-mm wide frame, Rack Angles can be mounted in-line with the frame; in an 800-mm wide frame, Adjustable Rack-Mounting Rails or Frame Reducing Brackets are required (sold separately) to achieve the 19-inch rack spacing
  • Double-Bay Frames: in a 1200-mm wide frame, Center Uprights must be used to create a mounting surface in the center of the enclosure for either bay; in a 1600-mm frame, Center Uprights are again required in addition to Frame Reducing Brackets or Adjustabl
  • Tapped-Hole Rack Angles accommodate 10-32 screws for equipment mounting
  • Square-Hole Rack Angles accept both metric and English cage nuts and screws: most commonly M5, M6, and 10-32 screws
  • Optional Shelves, Drawers, and Guides require two sets of Rack Angles to secure within the frame
  • All mounting hardware for Rack Angle installation into the frame is included; mounting hardware for securing rack-mount equipment/accessories to the Rack Angles is either supplied with the item or purchased separately
  • Tapped Rack Angles are constructed from 12 gauge (2.5 mm) conductive steel, while Square-Hole Rack Angles are from 14 gauge (1.75 mm) conductive steel
  • Load rating of 20 lbs (9.1 kg) per rack unit for equipment under 20-inches (508 mm) in depth; All equipment over 20-inches in depth requires rear rack angles for support

Specifications

Application
Controls and Drives
Color
Unpainted
Depth
1.89
Depth
48
Finish
Plated
Fits Frame Height
2000 mm
Height
75.3
Height
1,913
Hole Type
Square
Material
Mild Steel
Product Family
ProLine
Rack Units
43
Thickness
14 ga
Thickness
1.9 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
17 lb
Width
2.56
Width
65
Package Dimensions (L x W x H)
86.25 IN x 5.5 IN x 5.5 IN
Package Dimensions (L x W x H)
219.075 cm x 13.97 cm x 13.97 cm
Package Weight (Imperial)
17.000 L
Package Weight (Metric)
7.711 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2RA19S20 Controller

This guide provides step-by-step instructions for installing and configuring the P2RA19S20 controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2RA19S20 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Verify that the connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and use the configuration software to set the desired parameters. Follow the on-screen instructions to complete the setup.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.