nVent P2PSO88G - ProLine G2 Swing-Out Mounting Subpanel, 800x800, Conductive
nVent

P2PSO88G

UPC: 783510334956


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Swing-Out Mounting Subpanel, SKU P2PSO88G, is a critical component for efficient and accessible enclosure management in demanding industrial environments. Designed to integrate seamlessly with nVent's ProLine G2 modular enclosure system, this conductive subpanel allows for a front-mounted panel to pivot outwards from the enclosure frame. This innovative swing-out functionality provides unparalleled access to internal components, significantly simplifying installation, maintenance, and troubleshooting tasks. Engineered for robust performance, the ProLine G2 Swing-Out Subpanel is constructed from high-quality, conductive materials, ensuring reliable grounding and protection against electromagnetic interference (EMI) and electrostatic discharge (ESD). Its substantial 800x800mm dimensions offer ample surface area for mounting a wide array of electrical and electronic equipment, including control panels, PLCs, HMIs, power distribution units, and instrumentation. The intuitive swing-out mechanism is built for durability and ease of use, allowing operators to safely extend the subpanel to a convenient working position, often supported by integrated latches or locking mechanisms to maintain stability during access. This feature is particularly valuable in applications where space is limited or frequent access to the enclosure's interior is required. Key benefits of implementing the nVent ProLine G2 Swing-Out Mounting Subpanel include: * **Enhanced Accessibility:** The primary advantage is the ability to swing the subpanel out, providing unobstructed access to wiring and components without needing to remove the entire enclosure or disturb other mounted equipment. This dramatically reduces downtime during maintenance or modifications. * **Streamlined Installation:** Mounting components onto the subpanel before swinging it into the enclosure simplifies the overall assembly process, allowing for more organized and efficient wiring. * **Improved Safety:** By providing a stable and accessible platform, the swing-out design minimizes the risk of electrical shock or injury during servicing. Conductive construction further ensures proper grounding. * **Space Optimization:** In confined spaces, the swing-out feature allows for effective utilization of the enclosure's depth, enabling front access without requiring extensive surrounding clearance. * **Durability and Reliability:** Manufactured by nVent, a globally recognized leader in electrical enclosure solutions, this subpanel is built to withstand harsh industrial conditions, ensuring long-term operational integrity. Typical applications for the nVent ProLine G2 Swing-Out Mounting Subpanel span across various industries, including manufacturing automation, process control, power generation and distribution, telecommunications, and transportation infrastructure. It is an ideal solution for control cabinets, server racks, and any modular enclosure system where ease of access and efficient component management are paramount. The UNSPSC code 39121334 categorizes this product under electrical enclosure accessories, highlighting its role in comprehensive electrical system design. The US origin further underscores a commitment to quality manufacturing standards. When selecting an enclosure solution, the nVent ProLine G2 Swing-Out Mounting Subpanel offers a superior combination of functionality, accessibility, and robust construction, making it a preferred choice for professionals seeking to optimize their industrial control and automation systems.
  • Panels provide 170 degrees of rotation, with capability to hinge on either the right or left side
  • Spring-loaded pivot post allows for easy installation
  • Conductive or painted versions available
  • Simplifies wiring and component management within modular enclosure systems
  • Ideal for industrial automation, control panels, and power distribution applications

Specifications

Application
Controls and Drives; Power Distribution
Color
Unpainted
Finish
Galvanized
Fits Frame
800x800 mm
Material
Mild Steel
Product Family
ProLine
Thickness
12 ga
Thickness
2.66 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
54 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2PSO88G Controller

This guide provides step-by-step instructions for installing and configuring the P2PSO88G Controller for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2PSO88G controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power input terminals. Verify that the connections are tight and insulated to prevent short circuits.

  3. Configure the controller settings

    Power on the controller and access the configuration menu using the designated interface. Follow the on-screen prompts to set the desired parameters for operation.

  4. Calibrate the controller

    Perform a calibration procedure as outlined in the user manual. This may involve adjusting settings based on the specific application requirements.

  5. Test the installation

    After completing the setup, conduct a test run to ensure the controller operates as expected. Monitor for any irregularities and make adjustments as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.