nVent P2PSO148G - ProLine G2 Swing-Out Mounting Subpanel, 1400x800, Conductive
nVent

P2PSO148G

UPC: 783510334987


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Swing-Out Mounting Subpanel (SKU: P2PSO148G) is a high-performance, conductive mounting solution designed for modular enclosures in industrial and commercial electrical applications. Engineered by nVent, a global leader in electrical and thermal management solutions, this subpanel enables front-mounted components to pivot outward for simplified access, maintenance, and cable management—without requiring enclosure removal. The 1400x800mm conductive design ensures optimal grounding and electromagnetic compatibility, making it ideal for sensitive electronics and high-power systems where signal integrity and safety are critical. This swing-out subpanel is part of the ProLine G2 series, renowned for its modularity, durability, and compliance with stringent industry standards. Its conductive surface minimizes static discharge and interference, protecting sensitive equipment in data centers, telecommunications facilities, and industrial automation environments. The pivot mechanism allows technicians to service components quickly, reducing downtime and improving operational efficiency in mission-critical applications. Key applications include control panel assemblies, power distribution units, and industrial automation systems where frequent access to internal components is required. The subpanel’s large opening accommodates complex wiring harnesses and large components, while its robust construction withstands harsh industrial conditions, including vibration, temperature fluctuations, and electromagnetic interference. Professionals in the electrical contracting, manufacturing, and energy sectors rely on nVent’s ProLine G2 series for its reliability and ease of integration with existing enclosure systems. Installation is straightforward, with pre-drilled mounting holes for compatibility with standard enclosure frames. The conductive finish ensures seamless grounding when paired with nVent’s complementary grounding and bonding solutions, enhancing system safety and performance. As part of nVent’s trusted portfolio, this subpanel benefits from the company’s decades of expertise in electrical infrastructure, offering peace of mind for designers, engineers, and facility managers. Whether upgrading legacy systems or designing new installations, the nVent ProLine G2 Swing-Out Mounting Subpanel delivers unmatched versatility, durability, and accessibility. Its combination of conductive properties, modular design, and ease of maintenance makes it a preferred choice for professionals seeking to optimize their electrical enclosures for long-term reliability and operational efficiency.
  • Panels provide 170 degrees of rotation, with capability to hinge on either the right or left side
  • Spring-loaded pivot post allows for easy installation
  • Conductive or painted versions available
  • Compatible with nVent ProLine G2 enclosure systems and standard mounting frames
  • Manufactured in the US by nVent, a leader in electrical and thermal management solutions

Specifications

Application
Controls and Drives; Power Distribution
Color
Unpainted
Finish
Galvanized
Fits Frame
1400x800 mm
Material
Mild Steel
Material
Conductive
Mounting Type
Swing-Out
Product Family
ProLine
Series
ProLine G2
Size
1400x800
Size
1400x800 mm
Thickness
12 ga
Thickness
2.66 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
75 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2PSO148G Controller

This guide provides step-by-step instructions for installing and configuring the P2PSO148G Controller for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2PSO148G controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power input terminals. Verify that the connections are secure and insulated.

  3. Configure the controller settings

    Power on the controller and use the interface to navigate to the settings menu. Adjust the parameters as needed for your specific application.

  4. Calibrate the system

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired specifications.

  5. Test the installation

    Use a multimeter to verify that the output signals from the controller are within the expected range. Make any necessary adjustments.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.