
nVent P2PSM86G ProLine G2 Full Side-Mounting Subpanel, 800x600, Conductive
UPC: 783510325985
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Accommodates five loading options: vertical front, vertical side, vertical rear, horizontal front (frame over subpanel), horizontal rear (subpanel lowered into frame)
- High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
- Mounting subpanel is securely fastened at the top and bottom of the enclosure; subpanels less than 1200mm wide include four sets of EZ-Load Glide Blocks, four BV-M6 fasteners (block to frame) and four M12 Hex Bolts (subpanel to block); Subpanels 1200mm an
- Subpanels greater than 1000mm wide are 11 gauge (3.0 mm) mild steel, while subpanels 100mm or narrower are 12 gauge (2.5mm); conductive or white painted finish available
- Subpanels can be mounted at any depth in 25-mm increments (front to back); accommodates back-to-back and fully recessed rear positions
- Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames
- Optional panel support bracket available for applications requiring more support in the center of the subpanel; this is required if the enclosure will be tipped in transit or if the panel is not located at the bottom of the enclosure on the glide blocks
- Panels can be installed in the rearmost position, or positioned so joined enclosures provide a continuous mounting surface without requiring joining panels
- High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
- Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames
Specifications
Application | Power Distribution; Controls and Drives |
Color | Unpainted |
Finish | Galvanized |
Fits Frame | 800X600 mm |
Material | Galvanized Steel |
Material | Mild Steel |
Mounting Type | Side-Mounting |
Product Family | ProLine |
Series | ProLine G2 |
Size | 800x600 mm |
Thickness | 12 ga |
Thickness | 2.66 mm |
Type | Side Mount (Galvanized) |
Weight | 28.8 lb |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the P2PSM86G PROLINE G2 Enclosure
Installation guide for mounting and securing the P2PSM86G PROLINE G2 enclosure.
Estimated time: 1h
Tools needed:
Measuring tape, Level, Drill, Screwdriver, Pliers, Wire strippers, Wire cutters
Supplies needed:
Mounting hardware (screws, bolts, nuts), Wire connectors, Grounding lug, Gasket material (if applicable)
- Prepare the Mounting Location
Select a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Check the enclosure's nameplate or datasheet for specific weight information. Use a measuring tape and level to mark the mounting hole positions accurately.
- Drill Mounting Holes
Using the marked positions as a guide, drill the necessary holes in the mounting surface. Ensure the drill bit size is appropriate for the chosen mounting hardware. Clean any debris from the drilled holes.
- Mount the Enclosure
Position the P2PSM86G enclosure against the mounting surface, aligning the enclosure's mounting holes with the drilled holes. Insert the appropriate mounting hardware (screws, bolts) and tighten them securely using a screwdriver or wrench. Verify that the enclosure is level and firmly attached.
- Install Gasket (if applicable)
If your enclosure came with a gasket, carefully install it around the door or opening according to the manufacturer's instructions. Ensure a tight seal to protect the interior from environmental elements. Check the datasheet for specific gasket installation procedures.
- Ground the Enclosure
Connect a grounding wire to the designated grounding lug on the enclosure using appropriate hardware. Ensure the connection is secure and meets local electrical codes. Refer to the enclosure's nameplate or datasheet for grounding specifications.
- Wire Internal Components
Install any internal components as required. Use wire strippers and wire cutters to prepare wires for connection. Connect wires to terminals using wire connectors, ensuring all connections are secure and properly insulated. Follow the wiring diagrams provided in the product's datasheet.
- Final Inspection
Before closing the enclosure, perform a final inspection. Verify that all components are securely mounted, all wiring is correct and insulated, and there is no debris inside the enclosure. Ensure all safety warnings and instructions have been followed.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.
















