Authorized nVent Distributor
nVent P2PP78G - ProLine G2 Partial Subpanel, 700x800, Conductive

nVent P2PP78G ProLine G2 Partial Subpanel, 700x800, Conductive

UPC: 783510335571


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Partial Subpanel (SKU: P2PP78G) is a critical component for efficient enclosure management, designed to optimize internal space utilization while providing a robust platform for mounting electrical and electronic components. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this partial subpanel offers a conductive surface, ensuring proper grounding and electrical safety within your industrial control systems. Its 700x800mm dimensions are engineered to fit seamlessly within larger nVent ProLine G2 enclosures, maximizing usable internal real estate without compromising structural integrity. This partial subpanel is ingeniously designed to secure directly to the enclosure's frame or grid straps, a method that prevents the consumption of valuable internal volume typically required for full subpanel installations. This space-saving design is particularly advantageous in applications where internal space is at a premium, allowing for more components or improved airflow and thermal management. Furthermore, the ProLine G2 Partial Subpanel is also available in a versatile side-mount configuration, offering flexibility in installation and component layout to meet diverse project requirements. Engineered for demanding industrial environments, the ProLine G2 Partial Subpanel is constructed from high-quality materials, ensuring durability and long-term performance. Its conductive nature is essential for maintaining a consistent ground path for mounted equipment, a fundamental requirement for reliable operation and personnel safety in electrical installations. The UNSPSC code 39121334 categorizes this product within electrical equipment and accessories, highlighting its role in comprehensive electrical system builds. Key benefits of integrating the nVent ProLine G2 Partial Subpanel into your enclosure design include: * **Optimized Space Utilization:** Mount components without sacrificing primary internal enclosure space. * **Enhanced Flexibility:** Available in frame-mount and side-mount configurations to suit various layout needs. * **Reliable Grounding:** Conductive surface ensures proper electrical grounding for mounted components. * **Durable Construction:** Built to withstand harsh industrial conditions, ensuring longevity. * **Seamless Integration:** Designed to fit perfectly within nVent ProLine G2 enclosures. Professionals in industries such as manufacturing, automation, power distribution, and telecommunications rely on nVent's commitment to quality and innovation. The ProLine G2 Partial Subpanel exemplifies this, providing a practical and effective solution for managing complex electrical assemblies. Its US origin further underscores a commitment to manufacturing excellence. Whether you are designing a new control panel or upgrading an existing system, the nVent ProLine G2 Partial Subpanel offers a superior method for component mounting and enclosure organization, contributing to safer, more efficient, and more reliable electrical installations.
  • 12 gauge (2.5mm) mild steel; available standard in painted white or conductive finish
  • Flanges on all four sides for increased rigidity
  • Partial subpanels can be placed in the rearmost position of the enclosure at any vertical height in 25-mm increments, or placed at any depth using grid straps (not included)
  • Side-mount partial subpanels can be placed on either side at any vertical height in 25-mm increments
  • All necessary mounting hardware is included

Specifications

Application
Controls and Drives; Power Distribution
Color
Unpainted
Finish
Galvanized
Fits Frame
700x800 mm
Material
Mild Steel
Product Family
ProLine
Thickness
12 ga
Thickness
2.66 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
35 lb
Package Dimensions (L x W x H)
33 IN x 32.5 IN x 5 IN
Package Dimensions (L x W x H)
83.82 cm x 82.55 cm x 12.7 cm
Package Weight (Imperial)
35.000 L
Package Weight (Metric)
15.876 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2PP78G Controller

This guide provides step-by-step instructions for installing and configuring the P2PP78G Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2PP78G controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the appropriate terminals on the controller. Ensure all connections are tight and secure.

  3. Power on the controller

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage at the terminals is within the specified range.

  4. Configure the settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate operation. Make adjustments as needed based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.