The nVent ProLine G2 Disconnect Mounting Subpanel (SKU: P2PD1818G) is a critical component for constructing robust and customized industrial enclosure solutions. Designed for use with ProLine G2 Disconnect Frames and Doors, this subpanel enables the configuration of enclosure systems exceeding 1000 mm in width, offering unparalleled flexibility for complex electrical installations. This specific subpanel is engineered with conductive properties, ensuring proper grounding and electrical safety within the enclosure. Engineered by nVent, a recognized leader in electrical enclosure solutions, the ProLine G2 series is synonymous with quality, durability, and advanced functionality. This 1800x1800mm conductive subpanel is an integral part of the ProLine G2 system, allowing for the secure mounting of disconnect switches and other essential electrical equipment. Its substantial dimensions make it ideal for housing larger or multiple disconnect devices, catering to high-capacity power distribution and control applications. The ProLine G2 Disconnect Mounting Subpanel shares the same high standards as other ProLine G2 components, ensuring seamless integration and a cohesive enclosure build. A key design consideration for this subpanel, when used in conjunction with specific ProLine G2 configurations, is the offset center support. This offset, measuring 100mm, is strategically implemented to accommodate the hinged mullion, a feature crucial for providing access to the enclosure's interior while maintaining structural integrity and environmental protection. This thoughtful engineering detail simplifies installation and maintenance processes for complex, wide enclosures. Typical applications for the nVent ProLine G2 Disconnect Mounting Subpanel include heavy industrial environments such as manufacturing plants, power generation facilities, water treatment plants, and data centers. It is essential for applications requiring reliable and safe isolation of electrical circuits, particularly where large-scale power distribution or motor control is involved. The conductive nature of the subpanel is paramount for ensuring that all mounted components are effectively grounded, mitigating electrical hazards and protecting sensitive equipment from surges and faults. When selecting a mounting subpanel, professionals prioritize factors such as material quality, dimensional accuracy, load-bearing capacity, and compatibility with the overall enclosure system. The nVent ProLine G2 Disconnect Mounting Subpanel excels in these areas, offering a dependable foundation for critical electrical infrastructure. Its robust construction ensures longevity even in demanding operational conditions, contributing to the overall reliability and safety of the electrical system it protects. The UNSPSC code 39121334 further categorizes this product within the electrical equipment and supplies sector, highlighting its specific industrial application. Key benefits of utilizing the nVent ProLine G2 Disconnect Mounting Subpanel include: * **Enhanced Configurability:** Enables the creation of custom-width enclosure solutions exceeding 1000 mm. * **Superior Electrical Safety:** Conductive design ensures effective grounding for all mounted components. * **Robust Construction:** Built to nVent's high standards for durability and long-term performance. * **Simplified Installation:** Offset center support accommodates hinged mullions for easier access. * **Reliable Component Mounting:** Provides a stable and secure platform for disconnect switches and other devices. Manufactured in the USA, this subpanel reflects a commitment to quality and domestic production. Choosing nVent ProLine G2 components means investing in a proven system designed for the most demanding industrial environments, ensuring operational continuity and personnel safety.
  • Disconnect specific mounting subpanels are required for frames greater than 1000mm in width; any width 1000mm or less uses a standard mounting subpanel
  • 10 gauge (3.0 mm) mild steel; conductive plated option only
  • Includes eight sets of EZ-Load Glide Blocks, BV-M6 and Hex Bolts for securing
  • Similar in construction and function to the standard mounting subpanel, but with 100mm offset mounting holes near the middle of the subpanel, due to the presence of the disconnect mullion door in the enclosure solution
  • Disconnect mounting subpanel comes standard with Disconnect Package

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Unpainted
Finish
Galvanized
Fits Frame
1800 x 1800 mm
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
1800x1800 mm
Thickness
10 ga
Thickness
3.4 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
185 lb
Package Dimensions (L x W x H)
69 IN x 62 IN x 3.5 IN
Package Dimensions (L x W x H)
175.26 cm x 157.48 cm x 8.89 cm
Package Weight (Imperial)
185.000 L
Package Weight (Metric)
83.916 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2K18108E Controller

This guide provides step-by-step instructions for installing and configuring the P2K18108E Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K18108E controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and properly insulated.

  3. Configure the controller settings

    Power on the controller and use the interface to navigate to the settings menu. Adjust the parameters as required for your application and save the configuration.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Use a multimeter to verify output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.